The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Ratiometric Detection of Cr3+and Hg2+by a Naphthalimide-Rhodamine Based Fluorescent Probe
Abstract
Newly synthesized rhodamine derivatives, L(1) and L(2), are found to bind specifically to Hg(2+) or Cr(3+) in presence of large excess of other competing ions with associated changes in their optical and fluorescence spectral behavior. These spectral changes are significant enough in the visible region of the spectrum and thus, allow the visual detection. For L(1), the detection limit is even lower than the permissible [Cr(3+)] or [Hg(2+)] in drinking water as per standard U.S. EPA norms; while the receptor, L2 could be used as a ratiometric sensor for detection of Cr(3+) and Hg(2+) based on the resonance energy transfer (RET) process involving the donor naphthalimide and the acceptor Cr(3+)/Hg(2+)-bound xanthene fragment. Studies reveal that these two reagents could be used for recognition and sensing of Hg(2+)/Cr(3+). Further, confocal laser microscopic studies confirmed that the reagent L(2) could also be used as an imaging probe for detection of uptake of these ions in A431 cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Density-functional thermochemistry. III. The role of exact exchange
Becke, A. D. (1993) · The Journal of Chemical Physics · doi:10.1063/1.464913 · Cited by 103,767
Lee, C., Yang, W., & Parr, R. G. (1988) · Physical Review B · doi:10.1103/physrevb.37.785 · Cited by 100,874
Zwischenmolekulare Energiewanderung und Fluoreszenz
Förster, T. (1948) · Annalen der Physik · doi:10.1002/andp.19484370105 · Cited by 8,285
Ab initio molecular orbital theory
Hehre, W. J. (1976) · Accounts of Chemical Research · doi:10.1021/ar50107a003 · Cited by 7,930
Ab initio molecular orbital theory
W, J. O.-T. (1987) · Journal of Molecular Structure: THEOCHEM · doi:10.1016/0166-1280(87)85077-7 · Cited by 4,438
The Chemical Form of Mercury in Fish
Harris, H. H., Pickering, I. J., & George, G. N. (2003) · Science · doi:10.1126/science.1085941 · Cited by 1,353
A Long-Wavelength Fluorescent Chemodosimeter Selective for Cu(II) Ion in Water
Dujols, V., Ford, F., & Czarnik, A. W. (1997) · Journal of the American Chemical Society · doi:10.1021/ja971221g · Cited by 987
Resonance Energy Transfer: Theory and Data
van der Meer, B. W., Coker, E. G., & Chen, S.-Y. S. (1994) · Cited by 679
In Vivo Monitoring of Mercury Ions Using a Rhodamine-Based Molecular Probe
Ko, S.-K., Yang, Y.-K., Tae, J., & Shin, I. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065114a · Cited by 509
Chemosensors of Ion and Molecule Recognition
(1997) · Springer eBooks · doi:10.1007/978-94-011-3973-1 · Cited by 488
Bioremediation of metal contamination
Lovley, D. R., & Coates, J. D. (1997) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(97)80005-5 · Cited by 449
Zhu, Z., Su, Y., Li, J., Li, D., Zhang, J., Song, S., Zhao, Y., Li, G., & Fan, C. (2009) · Analytical Chemistry · doi:10.1021/ac9010809 · Cited by 431
Qian, F., Zhang, C., Zhang, Y., He, W., Gao, X., Hu, P., & Guo, Z. (2009) · Journal of the American Chemical Society · doi:10.1021/ja806489y · Cited by 424
Chemical Sensors and Biosensors for Medical and Biological Applications
Spichiger‐Keller, U. E. (1998) · Wiley eBooks · doi:10.1002/9783527612284 · Cited by 419
FRET-based sensor for imaging chromium(iii) in living cells
Zhou, Z., Yu, M., Yang, H., Huang, K., Li, F., Yi, T., & Huang, C. (2008) · Chemical Communications · doi:10.1039/b801503a · Cited by 379
Bioremediation of organic and metal contaminants with dissimilatory metal reduction
Lovley, D. R. (1995) · Journal of Industrial Microbiology · doi:10.1007/bf01569889 · Cited by 323
Highly Sensitive and Selective Chemosensor for Hg2+ Based on the Rhodamine Fluorophore
Lee, M. H., Wu, J.-S., Lee, J. W., Jung, J. H., & Kim, J. S. (2007) · Organic Letters · doi:10.1021/ol0708931 · Cited by 317
Liu, Q., Peng, J., Sun, L., & Li, F. (2011) · ACS Nano · doi:10.1021/nn202620u · Cited by 263
Organic anion transporters: discovery, pharmacology, regulation and roles in pathophysiology
VanWert, A. L., Gionfriddo, M. R., & Sweet, D. H. (2010) · Biopharmaceutics & Drug Disposition · doi:10.1002/bdd.693 · Cited by 252
Bacterial reduction of hexavalent chromium
Wang, Y.-T., & Shen, H. (1995) · Journal of Industrial Microbiology · doi:10.1007/bf01569898 · Cited by 245
Quest for the Molecular Mechanism of Chromium Action and Its Relationship to Diabetes
Vincent, J. B. (2009) · Nutrition Reviews · doi:10.1111/j.1753-4887.2000.tb01841.x · Cited by 214
Martínez, R., Zapata, F., Caballero, A., Ferao, A. E., Tárraga, A., & Molina, P. (2006) · Organic Letters · doi:10.1021/ol0610791 · Cited by 207
Chromium-induced genotoxicity and apoptosis: relationship to chromium carcinogenesis (review).
Singh, J., Carlisle, D. L., Pritchard, D. E., & Patierno, S. R. (1998) · Oncology Reports · doi:10.3892/or.5.6.1307 · Cited by 189
Metal-Ion-Responsive Fluorescent Probes for Two-Photon Excitation Microscopy
Sumalekshmy, S., & Fahrni, C. J. (2011) · Chemistry of Materials · doi:10.1021/cm1021905 · Cited by 169
A Rhodamine-Based Chemosensor that Works in the Biological System
Suresh, M., Shrivastav, A., Mishra, S., Suresh, E., & Das, A. (2008) · Organic Letters · doi:10.1021/ol800976d · Cited by 133
Self-citationWu, Y., Jing, H., Dong, Z., Zhao, Q., Wu, H., & Li, F. (2011) · Inorganic Chemistry · doi:10.1021/ic102082k · Cited by 123
Toxicity of Cr(III) to Shewanella sp. Strain MR-4 during Cr(VI) Reduction
Bernier‐Latmani, R., Obraztsova, A., Mackey, M. R., Ellisman, M. H., & Tebo, B. M. (2006) · Environmental Science & Technology · doi:10.1021/es0622655 · Cited by 116
Ma, C., Zeng, F., Huang, L., & Wu, S. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp109594h · Cited by 113
Liu, Y., Li, M., Zhao, Q., Wu, H., Huang, K., & Li, F. (2011) · Inorganic Chemistry · doi:10.1021/ic102481x · Cited by 110
A Ratiometric Fluorescent Probe Based on FRET for Imaging Hg2+ Ions in Living Cells
Zhang, X., Xiao, Y., & Qian, X. H. (2008) · Angewandte Chemie · doi:10.1002/ange.200803246 · Cited by 85
Jiang, P., Chen, L., Lin, J., Liu, Q., Ding, J., Gao, X., & Guo, Z. (2002) · Chemical Communications · doi:10.1039/b202976f · Cited by 82
A ‘turn-on’ FRET peptide sensor based on the mercury bindingprotein MerP
White, B. R., Liljestrand, H. M., & Holcombe, J. A. (2007) · The Analyst · doi:10.1039/b711777a · Cited by 76
The detection of Hg2+ by cyanobacteria in aqueous media
Suresh, M., Mishra, S. K., Mishra, S., & Das, A. (2009) · Chemical Communications · doi:10.1039/b821687h · Cited by 59
Self-citationPagano, G., Manini, P., & Bagchi, D. (2003) · Environmental Health Perspectives · doi:10.1289/ehp.6229 · Cited by 29
Metadata
- Authors
- Mahato, P., Saha, S., Suresh, E., Di Liddo, R., Parnigotto, P. P., Conconi, M. T., Kesharwani, M. K., Ganguly, B., & Das, A.
- Venue
- Inorganic Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-11
- Volume
- 51
- Issue
- 3
- Pages
- 1769-1777
- ISSN
- 0020-1669 (ISSN-L)
- 1520-510X
- OpenAlex
- W2329313914
- Cited by
- 319
- References
- 34
- FWCI
- 19.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.