The DOI matches its Crossref record.
Electrical connection of enzyme redox centers to electrodes
Abstract
Electrically insulating proteins can be made redox-conducting through incorporation of a high density of electron relaying redox centers. Electrons diffuse in the resulting redox conductors by self-exchange between identical and electron transfer between different relaying centers. When the self-exchange rate of the relays and their density are high, the flux of electrons through a 1 micrometer thick film of a 3-dimensional macromolecular network can match or exceed the rate of supply of electrons to or from the ensemble of enzyme molecules covalently bound to it. The network now molecularly wires the enzyme molecules to the electrode and the current measures the turnover of the wired enzyme molecules. When the enzyme turnover is substrate-flux, i.e. concentration limited, the current increases with the concentration of the substrate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Integrated Nanoparticle–Biomolecule Hybrid Systems: Synthesis, Properties, and Applications
Katz, E., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200400651 · Cited by 2,450
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
"Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle
Xiao, Y., Patolsky, F., Katz, E., Hainfeld, J. F., & Willner, I. (2003) · Science · doi:10.1126/science.1080664 · Cited by 1,270
New Challenges in Biomaterials
Peppas, N. A., & Langer, R. (1994) · Science · doi:10.1126/science.8134835 · Cited by 1,142
Biofuel cells and their development
Bullen, R. A., Arnot, T. C., Lakeman, J. B., & Walsh, F. C. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.030 · Cited by 1,011
The Rise of Organic Bioelectronics
Rivnay, J., Owens, R. M., & Malliaras, G. G. (2014) · Chemistry of Materials · doi:10.1021/cm4022003 · Cited by 713
Heller, A. (2004) · Physical Chemistry Chemical Physics · doi:10.1039/b313149a · Cited by 660
Self-citationWhy is Ferrocene so Exceptional?
Astruc, D. (2017) · European Journal of Inorganic Chemistry · doi:10.1002/ejic.201600983 · Cited by 653
Carbon paste electrodes modified with enzymes, tissues, and cells
Gorton, L. (1995) · Electroanalysis · doi:10.1002/elan.1140070104 · Cited by 515
Biomolecular immobilization on conducting polymers for biosensing applications
Ahuja, T., Mir, I. A., Kumar, D., & Rajesh (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.09.046 · Cited by 502
Self-Powered Enzyme-Based Biosensors
Katz, E., Bückmann, A. F., & Willner, I. (2001) · Journal of the American Chemical Society · doi:10.1021/ja0167102 · Cited by 482
Willner, I., Heleg-Shabtai, V., Blonder, R., Katz, E., Tao, G., Bückmann, A. F., & Heller, A. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9608611 · Cited by 370
Self-citationRecent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing
Hassan, M. H., Vyas, C., Grieve, B., & Bartolo, P. (2021) · Sensors · doi:10.3390/s21144672 · Cited by 364
The organic electrochemical transistor for biological applications
Strakosas, X., Bongo, M., & Owens, R. M. (2015) · Journal of Applied Polymer Science · doi:10.1002/app.41735 · Cited by 350
O2Reduction in Enzymatic Biofuel Cells
Mano, N., & de Poulpiquet, A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00220 · Cited by 337
Fructose/dioxygen biofuel cell based on direct electron transfer-type bioelectrocatalysis
Kamitaka, Y., Tsujimura, S., Setoyama, N., Kajino, T., & Kano, K. (2007) · Physical Chemistry Chemical Physics · doi:10.1039/b617650j · Cited by 335
Biomaterials for Sensors, Fuel Cells, and Circuitry
Willner, I. (2002) · Science · doi:10.1126/science.298.5602.2407 · Cited by 312
Integrated nanoparticle–biomolecule systems for biosensing and bioelectronics
Willner, I., Baron, R., & Willner, B. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.09.018 · Cited by 312
On the electrical conductivity of microbial nanowires and biofilms
Strycharz-Glaven, S. M., Snider, R. M., Guiseppi-Elie, A., & Tender, L. M. (2011) · Energy & Environmental Science · doi:10.1039/c1ee01753e · Cited by 301
Organic Electronics at the Interface with Biology
Owens, R. M., & Malliaras, G. G. (2010) · MRS Bulletin · doi:10.1557/mrs2010.583 · Cited by 294
Biomolecule-Based Nanomaterials and Nanostructures
Willner, I., & Willner, B. (2010) · Nano Letters · doi:10.1021/nl102083j · Cited by 290
Mano, N., & Heller, A. (2005) · Journal of the American Chemical Society · doi:10.1021/ja053937e · Cited by 285
Self-citationOhara, T. J., Rajagopalan, R., & Heller, A. (1993) · Analytical Chemistry · doi:10.1021/ac00071a031 · Cited by 281
Self-citationElectrochemical Reduction of CO2 at Functionalized Au Electrodes
Fang, Y., & Flake, J. C. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b11023 · Cited by 278
Long-range electron transport in Geobacter sulfurreducens biofilms is redox gradient-driven
Snider, R. M., Strycharz-Glaven, S. M., Tsoi, S. D., Erickson, J. S., & Tender, L. M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209829109 · Cited by 274
Castillo, J., Gáspár, S., Leth, S., Niculescu, M., Mortari, A., Bontidean, I., Soukharev, V., Dorneanu, S. A., Ryabov, A. D., & Csöregi, E. (2004) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2004.04.084 · Cited by 272
Integrated photosystem II-based photo-bioelectrochemical cells
Yehezkeli, O., Tel-Vered, R., Wasserman, J., Trifonov, A., Michaeli, D., Nechushtai, R., & Willner, I. (2012) · Nature Communications · doi:10.1038/ncomms1741 · Cited by 263
Katz, E., & Willner, I. (2004) · Angewandte Chemie · doi:10.1002/ange.200400651 · Cited by 260
Recent progress and continuing challenges in bio-fuel cells. Part I: Enzymatic cells
Osman, M. H., Shah, A. A., & Walsh, F. C. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.01.004 · Cited by 257
Electrochemistry in Diabetes Management
Heller, A., & Feldman, B. (2010) · Accounts of Chemical Research · doi:10.1021/ar9002015 · Cited by 255
Self-citationImplanted Electrochemical Glucose Sensors for the Management of Diabetes
Heller, A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.153 · Cited by 215
Self-citation
Metadata
- Authors
- Heller, A.
- Venue
- The Journal of Physical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1992-04
- Volume
- 96
- Issue
- 9
- Pages
- 3579-3587
- ISSN
- 0022-3654 (ISSN-L)
- 1541-5740
- OpenAlex
- W1981049234
- Cited by
- 603
- References
- 0
- FWCI
- 26.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.