The DOI matches its Crossref record.
Resistance of polyaniline films as a function of electrochemical potential and the fabrication of polyaniline-based microelectronic devices
Abstract
Anodic growth of polyaniline films on a Au microelectrode array has been carried out to add to the characterization of polyaniline and to fabricate polyaniline-based microelectronic devices, diodes and transistors, that function when the polyaniline-functionalized microelectrode array is immersed in an electrolyte solution. The microelectrode array is a set of eight Au electrodes, 0.1 micrometer thick, 4.4 micrometers wide and 50 micrometers long, each individually addressable and separated from each other by 1.7 micrometers. Polyaniline can be deposited in controlled amounts by electrochemical oxidation of aniline. When the polyaniline is deposited in sufficient amounts, two or more of the eight Au microelectrodes can be connected in the electrical sense. Current can pass between two connected microelectrodes when there is an applied potential between them. The magnitude of the current at a given applied potential depends on the electrochemical potential of the polyaniline. In 0.5 M NaHsSO4/H20 the current (at a fixed applied potential) is maximum at an electrochemical potential of approx. +0.4 V vs. SCE and declines by a factor of greater than 1,000,000 upon reduction to +0.1 or oxidation to +0,7 V vs. SCE. Owing to the large change in resistance upon change in electrochemical potential, the functionalized microelectrodes is crucial to device function, owing to the limited conductivity of the polyaniline. The switching time of a transistor-like device is faster than 0.1 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
‘Polyaniline’: Protonic acid doping of the emeraldine form to the metallic regime
Chiang, J.-C., & MacDiarmid, A. G. (1986) · Synthetic Metals · doi:10.1016/0379-6779(86)90070-6 · Cited by 1,979
Progress in preparation, processing and applications of polyaniline
Bhadra, S., Khastgir, D., Singha, N. K., & Lee, J. H. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.04.003 · Cited by 1,910
Color Control in π-Conjugated Organic Polymers for Use in Electrochromic Devices
Beaujuge, P. M., & Reynolds, J. R. (2010) · Chemical Reviews · doi:10.1021/cr900129a · Cited by 1,881
Electrolyte‐Gated Transistors for Organic and Printed Electronics
Kim, S. H., Hong, K., Xie, W., Lee, K. H., Zhang, S., Lodge, T. P., & Frisbie, C. D. (2013) · Advanced Materials · doi:10.1002/adma.201202790 · Cited by 957
Electrochemistry of Poly(3,4‐alkylenedioxythiophene) Derivatives
Groenendaal, L., Zotti, G., Aubert, P. ‐., Waybright, S. M., & Reynolds, J. R. (2003) · Advanced Materials · doi:10.1002/adma.200300376 · Cited by 944
Organic Thin‐Film Transistors for Chemical and Biological Sensing
Lin, P., & Yan, F. (2012) · Advanced Materials · doi:10.1002/adma.201103334 · Cited by 907
Electron and proton conducting polymers: recent developments and prospects
Inzelt, G., Pineri, M., Schultze, J. W., & Vorotyntsev, M. A. (2000) · Electrochimica Acta · doi:10.1016/s0013-4686(00)00329-7 · Cited by 715
Conducting polymers as active materials in electrochemical capacitors
Rudge, A., Davey, J., Raistrick, I., Gottesfeld, S., & Ferraris, J. P. (1994) · Journal of Power Sources · doi:10.1016/0378-7753(94)80053-7 · Cited by 707
Enzymatically Synthesized Conducting Polyaniline
Liu, W., Kumar, J., Tripathy, S., Senecal, K. J., & Samuelson, L. (1999) · Journal of the American Chemical Society · doi:10.1021/ja982270b · Cited by 504
Chemical and biological sensors based on organic thin-film transistors
Mabeck, J. T., & Malliaras, G. G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3390-2 · Cited by 479
Ultramicroelectrodes in Electrochemistry
Heinze, J. (1993) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199312681 · Cited by 470
Electrochemical Sensors Based on Organic Conjugated Polymers
Rahman, M. A., Kumar, P., Park, D.-S., & Shim, Y.-B. (2008) · Sensors · doi:10.3390/s8010118 · Cited by 464
Enzymatic sensing with organic electrochemical transistors
Bernards, D. A., Macaya, D. J., Nikolou, M., DeFranco, J. A., Takamatsu, S., & Malliaras, G. G. (2008) · J. Mater. Chem. · doi:10.1039/b713122d · Cited by 410
Prospects of conducting polymers in biosensors
Malhotra, B. D., Chaubey, A., & Singh, S. P. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.055 · Cited by 372
Comparative studies of solid-state synthesized polyaniline doped with inorganic acids
Abdiryim, T., Xiao-Gang, Z., & Jamal, R. (2005) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2004.10.036 · Cited by 335
Flexible room temperature ammonia sensor based on polyaniline
Kumar, L., Rawal, I., Kaur, A., & Annapoorni, S. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.08.173 · Cited by 326
Microfabrication of PPy microactuators and other conjugated polymer devices
Smela, E. (1999) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/9/1/001 · Cited by 318
Kukhta, N. A., Marks, A., & Luscombe, C. K. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00266 · Cited by 309
A Conducting Polymer Film Stronger Than Aluminum
Shi, G., Jin, S., Xue, G., & Li, C. (1995) · Science · doi:10.1126/science.267.5200.994 · Cited by 305
Kergoat, L., Piro, B., Berggren, M., Horowitz, G., & Pham, M.-C. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5363-y · Cited by 303
The Application of Organic Electrochemical Transistors in Cell‐Based Biosensors
Lin, P., Yan, F., Yu, J., Chan, H. L. W., & Yang, M. (2010) · Advanced Materials · doi:10.1002/adma.201000971 · Cited by 299
Pernaut, J.-M., & Reynolds, J. R. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp994274o · Cited by 293
Potentiometric Ion Sensors Based on Conducting Polymers
Bobacka, J., Ivaska, A., & Lewenstam, A. (2003) · Electroanalysis · doi:10.1002/elan.200390042 · Cited by 277
Kost, K. M., Bartak, D. E., Kazee, B., & Kuwana, T. (1988) · Analytical Chemistry · doi:10.1021/ac00172a012 · Cited by 265
Chemically modified electrodes. Molecular design for electroanalysis
Murray, R. W., Ewing, A. G., & Durst, R. A. (1987) · Analytical Chemistry · doi:10.1021/ac00132a001 · Cited by 252
Gopalan, A. I., Lee, K.-P., Manesh, K. M., Santhosh, P., & Kim, J. H. (2006) · Journal of Molecular Catalysis A: Chemical · doi:10.1016/j.molcata.2006.05.027 · Cited by 57
Metadata
- Authors
- Paul, E. W., Ricco, A. J., & Wrighton, M. S.
- Venue
- The Journal of Physical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1985-04
- Volume
- 89
- Issue
- 8
- Pages
- 1441-1447
- ISSN
- 0022-3654 (ISSN-L)
- 1541-5740
- OpenAlex
- W1991501551
- Cited by
- 1,026
- References
- 0
- FWCI
- 45.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.