The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Rational Design of Fluorescein-Based Fluorescence Probes. Mechanism-Based Design of a Maximum Fluorescence Probe for Singlet Oxygen
Abstract
Fluorescein is one of the best available fluorophores for biological applications, but the factors that control its fluorescence properties are not fully established. Thus, we initiated a study aimed at providing a strategy for rational design of functional fluorescence probes bearing fluorescein structure. We have synthesized various kinds of fluorescein derivatives and examined the relationship between their fluorescence properties and the highest occupied molecular orbital (HOMO) levels of their benzoic acid moieties obtained by semiempirical PM3 calculations. It was concluded that the fluorescence properties of fluorescein derivatives are controlled by a photoinduced electron transfer (PET) process from the benzoic acid moiety to the xanthene ring and that the threshold of fluorescence OFF/ON switching lies around -8.9 eV for the HOMO level of the benzoic acid moiety. This information provides the basis for a practical strategy for rational design of functional fluorescence probes to detect certain biomolecules. We used this approach to design and synthesize 9-[2-(3-carboxy-9,10-dimethyl)anthryl]-6-hydroxy-3H-xanthen-3-one (DMAX) as a singlet oxygen probe and confirmed that it is the most sensitive probe currently known for (1)O(2). This novel fluorescence probe has a 9,10-dimethylanthracene moiety as an extremely fast chemical trap of (1)O(2). As was expected from PM3 calculations, DMAX scarcely fluoresces, while DMAX endoperoxide (DMAX-EP) is strongly fluorescent. Further, DMAX reacts with (1)O(2) more rapidly, and its sensitivity is 53-fold higher than that of 9-[2-(3-carboxy-9,10-diphenyl)anthryl]-6-hydroxy-3H-xanthen-3-ones (DPAXs), which are a series of fluorescence probes for singlet oxygen that we recently developed. DMAX should be useful as a fluorescence probe for detecting (1)O(2) in a variety of biological systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Detection and Imaging of Nitric Oxide with Novel Fluorescent Indicators: Diaminofluoresceins
Kojima, H., Nakatsubo, N., Kikuchi, K., Kawahara, S., Kirino, Y., Nagoshi, H., Hirata, Y., & Nagano, T. (1998) · Analytical Chemistry · doi:10.1021/ac9801723 · Cited by 1,389
Self-citationFluorescent Indicators for Imaging Nitric Oxide Production
Kojima, H., Urano, Y., Kikuchi, K., Higuchi, T., Hirata, Y., & Nagano, T. (1999) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19991102)38:21<3209::aid-anie3209>3.0.co;2-6 · Cited by 570
Self-citationWilkinson, F., & Brummer, J. G. (1981) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555655 · Cited by 564
Murray‐Rust, P., Stallings, W. C., Monti, C. T., Preston, R. K., & GLUSKER, J. P. (1983) · Journal of the American Chemical Society · doi:10.1021/ja00348a041 · Cited by 310
Grether-Beck, S., Olaizola-Horn, S., Schmitt, H., Grewe, M., Jahnke, A., Johnson, J. P., Briviba, K., Sies, H., & Krutmann, J. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.25.14586 · Cited by 212
Novel Fluorescent Probes for Singlet Oxygen
Umezawa, N., Tanaka, K., Urano, Y., Kikuchi, K., Higuchi, T., & Nagano, T. (1999) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19991004)38:19<2899::aid-anie2899>3.0.co;2-m · Cited by 175
Self-citationSinglet oxygen induces collagenase expression in human skin fibroblasts
Scharffetter‐Kochanek, K., Wlaschek, M., Briviba, K., & Sies, H. (1993) · FEBS Letters · doi:10.1016/0014-5793(93)80357-z · Cited by 155
Fluorophores for Confocal Microscopy
Tsien, R. Y., & Waggoner, A. S. (1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6_16 · Cited by 147
Cited by
BODIPY Dyes and Their Derivatives: Syntheses and Spectroscopic Properties
Loudet, A., & Burgess, K. (2007) · Chemical Reviews · doi:10.1021/cr078381n · Cited by 5,238
Physical Mechanisms of Generation and Deactivation of Singlet Oxygen
Schweitzer, C., & Schmidt, R. (2003) · Chemical Reviews · doi:10.1021/cr010371d · Cited by 2,123
Fluorescence probes used for detection of reactive oxygen species
Gomes, A., Fernandes, E., & Lima, J. L. F. C. (2005) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2005.10.003 · Cited by 1,844
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Selective molecular imaging of viable cancer cells with pH-activatable fluorescence probes
Urano, Y., Asanuma, D., Hama, Y., Koyama, Y., Barrett, T., Kamiya, M., Nagano, T., Watanabe, T., Hasegawa, A., Choyke, P. L., et al. (2009) · Nature Medicine · doi:10.1038/nm.1854 · Cited by 801
Self-citationApak, R., Gorinstein, S., Böhm, V., Schaich, K. M., Özyürek, M., & Güçlü, K. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rep-12-07-15 · Cited by 586
Synthetic fluorescent probes for studying copper in biological systems
Cotruvo, Jr., Aron, A. T., Ramos-Torres, K. M., & Chang, C. J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00346b · Cited by 558
Methods for reactive oxygen species (ROS) detection in aqueous environments
Burns, J. M., Cooper, W. J., Ferry, J. L., King, D. W., DiMento, B. P., McNeill, K., Miller, C. J., Miller, W. L., Peake, B. M., Rusak, S. A., et al. (2012) · Aquatic Sciences · doi:10.1007/s00027-012-0251-x · Cited by 454
“Turn-on” fluorescent sensing with “reactive” probes
Eun Jun, M., Roy, B., & Han Ahn, K. (2011) · Chemical Communications · doi:10.1039/c1cc00014d · Cited by 434
Park, Y. I., Kim, H. M., Kim, J. H., Moon, K. C., Yoo, B., Lee, K. T., Lee, N., Choi, Y., Park, W., Ling, D., et al. (2012) · Advanced Materials · doi:10.1002/adma.201202433 · Cited by 395
Synthesis and application of coumarin fluorescence probes
Sun, X.-Y., Liu, T., Sun, J., & Wang, X.-J. (2020) · RSC Advances · doi:10.1039/c9ra10290f · Cited by 308
Singlet Oxygen Sensor Green®: Photochemical Behavior in Solution and in a Mammalian Cell
Gollmer, A., Arnbjerg, J., Blaikie, F. H., Pedersen, B. W., Breitenbach, T., Daasbjerg, K., Glasius, M., & Ogilby, P. R. (2011) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.2011.00900.x · Cited by 298
Zhang, R., Zhao, J., Han, G., Liu, Z., Liu, C., Zhang, C., Liu, B., Jiang, C., Liu, R., Zhao, T., et al. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.5b12848 · Cited by 288
Xie, Z.-H., He, C.-S., Pei, D.-N., Dong, Y., Yang, S.-R., Xiong, Z., Zhou, P., Pan, Z.-C., Yao, G., & Lai, B. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.143778 · Cited by 279
Activity‐Based Sensing: A Synthetic Methods Approach for Selective Molecular Imaging and Beyond
Bruemmer, K. J., Crossley, S. W. M., & Chang, C. J. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201909690 · Cited by 265
Metadata
- Authors
- Tanaka, K., Miura, T., Umezawa, N., Urano, Y., Kikuchi, K., Higuchi, T., & Nagano, T.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-02-27
- Volume
- 123
- Issue
- 11
- Pages
- 2530-2536
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2015413280
- Cited by
- 397
- References
- 14
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.