The DOI matches its Crossref record.
A DNAzyme Catalytic Beacon Sensor for Paramagnetic Cu2+ Ions in Aqueous Solution with High Sensitivity and Selectivity
Abstract
Copper is a key metal ion both in environment monitoring and in biology, and exposure to high concentration of copper can cause adverse health effects. Although significant progresses have been made in designing fluorescent sensors for diamagnetic metal ions, few effective Cu 2+ sensors are known because of the paramagnetic nature of the metal ion. We herein report a highly sensitive and selective “turn-on” fluorescent Cu 2+ sensor based on an in vitro selected DNAzyme (also known as catalytic DNA or deoxyribozyme). The substrate strand of the DNAzyme was labeled with a fluorophore on the 3‘-end and a quencher on the 5‘-end, and the enzyme strand was labeled with a second quencher on the 5‘-end. Initially, the fluorescence was quenched. Addition of Cu 2+ induced oxidative cleavage of the substrate, and the fluorescence intensity increased by 13-fold. The sensor has a detection limit of 35 nM and a dynamic range up to 20 μM. The sensor selectivity is more than 2000-fold for Cu 2+ over Fe 2+ and UO 2 2+ and more than 10 000-fold over any other metal ions. The DNAzyme catalytic beacon method demonstrated here can be applied to designing turn-on fluorescent sensors for other paramagnetic metal ions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zhou, W., Saran, R., & Liu, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00063 · Cited by 931
Self-citationColorimetric Biosensing Using Smart Materials
Song, Y., Wei, W., & Qu, X. (2011) · Advanced Materials · doi:10.1002/adma.201101853 · Cited by 666
Wang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Nucleic Acid Based Molecular Devices
Krishnan, Y., & Simmel, F. C. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.200907223 · Cited by 572
Zhao, Y., Zhang, X.-B., Han, Z.-X., Qiao, L., Li, C.-Y., Jian, L.-X., Shen, G.-L., & Yu, R.-Q. (2009) · Analytical Chemistry · doi:10.1021/ac901127n · Cited by 455
A DNAzyme-Gold Nanoparticle Probe for Uranyl Ion in Living Cells
Wu, P., Hwang, K., Lan, T., & Lu, Y. (2013) · Journal of the American Chemical Society · doi:10.1021/ja400150v · Cited by 428
Self-citationZhou, Y., Wang, F., Kim, Y., Kim, S.-J., & Yoon, J. (2009) · Organic Letters · doi:10.1021/ol901804n · Cited by 416
Recent advances in DNA-based electrochemical biosensors for heavy metal ion detection: A review
Saidur, M. R., Aziz, A. R. A., & Basirun, W. J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.11.039 · Cited by 339
Triplex DNA Nanostructures: From Basic Properties to Applications
Hu, Y., Cecconello, A., Idili, A., Ricci, F., & Willner, I. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201701868 · Cited by 336
DNAzyme-based biosensors and nanodevices
Gong, L., Zhao, Z., Lv, Y.-F., Huan, S.-Y., Fu, T., Zhang, X.-B., Shen, G.-L., & Yu, R.-Q. (2015) · Chemical Communications · doi:10.1039/c4cc06855f · Cited by 321
A Highly Selective DNAzyme Sensor for Mercuric Ions
Hollenstein, M., Hipolito, C., Lam, C., Dietrich, D., & Perrin, D. M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200800960 · Cited by 317
Yao, J., Zhang, K., Zhu, H., Ma, F., Sun, M., Yu, H., Sun, J., & Wang, S. (2013) · Analytical Chemistry · doi:10.1021/ac401011r · Cited by 286
Lake, R. J., Yang, Z., Zhang, J., & Lu, Y. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00419 · Cited by 281
Self-citationTaki, M., Iyoshi, S., Ojida, A., Hamachi, I., & Yamamoto, Y. (2010) · Journal of the American Chemical Society · doi:10.1021/ja100714p · Cited by 253
Wu, Y., Torabi, S.-F., Lake, R. J., Hong, S., Yu, Z., Wu, P., Yang, Z., Nelson, K., Guo, W., Pawel, G. T., et al. (2023) · Science Advances · doi:10.1126/sciadv.ade7622 · Cited by 91
Self-citationBiostable L-DNAzyme for Sensing of Metal Ions in Biological Systems
Cui, L., Peng, R., Fu, T., Zhang, X., Wu, C., Chen, H., Liang, H., Yang, C. J., & Tan, W. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04170 · Cited by 81
A general approach to the design of allosteric, transcription factor-regulated DNAzymes
Adornetto, G., Porchetta, A., Palleschi, G., Plaxco, K. W., & Ricci, F. (2015) · Chemical Science · doi:10.1039/c5sc00228a · Cited by 31
Metadata
- Authors
- Liu, J., & Lu, Y.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-07-24
- Volume
- 129
- Issue
- 32
- Pages
- 9838-9839
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2000542434
- Cited by
- 647
- References
- 0
- FWCI
- 11.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.