The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Regenerable DNA-Functionalized Hydrogels for Ultrasensitive, Instrument-Free Mercury(II) Detection and Removal in Water
Abstract
Mercury is a highly toxic environmental pollutant with bioaccumulative properties. Therefore, new materials are required to not only detect but also effectively remove mercury from environmental sources such as water. We herein describe a polyacrylamide hydrogel-based sensor functionalized with a thymine-rich DNA that can simultaneously detect and remove mercury from water. Detection is achieved by selective binding of Hg(2+) between two thymine bases, inducing a hairpin structure where, upon addition of SYBR Green I dye, green fluorescence is observed. In the absence of Hg(2+), however, addition of the dye results in yellow fluorescence. Using the naked eye, the detection limit in a 50 mL water sample is 10 nM Hg(2+). This sensor can be regenerated using a simple acid treatment and can remove Hg(2+) from water at a rate of approximately 1 h(-1). This sensor was also used to detect and remove Hg(2+) from samples of Lake Ontario water spiked with mercury. In addition, these hydrogel-based sensors are resistant to nuclease and can be rehydrated from dried gels for storage and DNA protection. Similar methods can be used to functionalize hydrogels with other nucleic acids, proteins, and small molecules for environmental and biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hazards of heavy metal contamination
Järup, L. (2003) · British Medical Bulletin · doi:10.1093/bmb/ldg032 · Cited by 6,508
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Tools and Tactics for the Optical Detection of Mercuric Ion
Nolan, E. M., & Lippard, S. J. (2008) · Chemical Reviews · doi:10.1021/cr068000q · Cited by 2,345
Functionalized Monolayers on Ordered Mesoporous Supports
Feng, X., Fryxell, G. E., Wang, L.-Q., Kim, A. Y., Liu, J., & Kemner, K. M. (1997) · Science · doi:10.1126/science.276.5314.923 · Cited by 1,562
Self-citationThe Chemical Form of Mercury in Fish
Harris, H. H., Pickering, I. J., & George, G. N. (2003) · Science · doi:10.1126/science.1085941 · Cited by 1,353
Lee, J., Han, M. S., & Mirkin, C. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700269 · Cited by 1,308
Review: Environmental exposure to mercury and its toxicopathologic implications for public health
Tchounwou, P. B., Ayensu, W. K., Ninashvili, N., & Sutton, D. (2003) · Environmental Toxicology · doi:10.1002/tox.10116 · Cited by 1,298
A reversibly antigen-responsive hydrogel
Miyata, T., Asami, N., & Uragami, T. (1999) · Nature · doi:10.1038/21619 · Cited by 1,166
Highly Selective Oligonucleotide‐Based Sensor for Mercury(II) in Aqueous Solutions
Ono, A., & Togashi, H. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200454172 · Cited by 1,162
MercuryII-Mediated Formation of Thymine−HgII−Thymine Base Pairs in DNA Duplexes
Miyake, Y., Togashi, H., Tashiro, M., Yamaguchi, H., Oda, S., Kudo, M., Tanaka, Y., Kondo, Y., Sawa, R., Fujimoto, T., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja056354d · Cited by 1,079
Enzyme-catalysed assembly of DNA hydrogel
Um, S. H., Lee, J. B., Park, N., Kwon, S. Y., Umbach, C. C., & Luo, D. (2006) · Nature Materials · doi:10.1038/nmat1741 · Cited by 869
Soft Nanotechnology with Soft Nanoparticles
Nayak, S., & Lyon, L. A. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200501321 · Cited by 855
Xue, X., Wang, F., & Liu, X. (2008) · Journal of the American Chemical Society · doi:10.1021/ja076716c · Cited by 709
Optical Analysis of Hg2+ Ions by Oligonucleotide–Gold‐Nanoparticle Hybrids and DNA‐Based Machines
Li, D., Wieckowska, A., & Willner, I. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200705991 · Cited by 682
Liu, J., & Lu, Y. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702006 · Cited by 593
Self-citation15N−15N J-Coupling Across HgII: Direct Observation of HgII-Mediated T−T Base Pairs in a DNA Duplex
Tanaka, Y., Oda, S., Yamaguchi, H., Kondo, Y., Kojima, C., & Ono, A. (2007) · Journal of the American Chemical Society · doi:10.1021/ja065552h · Cited by 541
Screening Mercury Levels in Fish with a Selective Fluorescent Chemosensor
Yoon, S., Albers, A. E., Wong, A. P., & Chang, C. J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0557987 · Cited by 503
A pH‐Triggered, Fast‐Responding DNA Hydrogel
Cheng, E., Xing, Y., Chen, P., Yang, Y., Sun, Y., Zhou, D., Xu, L., Fan, Q., & Liu, D. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200902538 · Cited by 498
Freeman, R., Finder, T., & Willner, I. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200902395 · Cited by 490
Review: Hydrogels for cell immobilization
Jen, A. C., Wake, M. C., & Mikos, A. G. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960520)50:4<357::aid-bit2>3.0.co;2-k · Cited by 484
Turn-On and Ratiometric Mercury Sensing in Water with a Red-Emitting Probe
Nolan, E. M., & Lippard, S. J. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068879r · Cited by 428
A Bright and Specific Fluorescent Sensor for Mercury in Water, Cells, and Tissue
Yoon, S., Miller, E. W., He, Q., Do, P. H., & Chang, C. J. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200701785 · Cited by 390
Ye, B., & Yin, B. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803069 · Cited by 386
An Aptamer Cross‐Linked Hydrogel as a Colorimetric Platform for Visual Detection
Zhu, Z., Wu, C., Liu, H., Zou, Y., Zhang, X., Kang, H., Yang, C. J., & Tan, W. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905570 · Cited by 364
Engineering Target-Responsive Hydrogels Based on Aptamer−Target Interactions
Yang, H., Liu, H., Kang, H., & Tan, W. (2008) · Journal of the American Chemical Society · doi:10.1021/ja801339w · Cited by 363
Liu, X., Tang, Y., Wang, L., Zhang, J., Song, S., Fan, C., & Wang, S. (2007) · Advanced Materials · doi:10.1002/adma.200602578 · Cited by 338
A Highly Selective DNAzyme Sensor for Mercuric Ions
Hollenstein, M., Hipolito, C., Lam, C., Dietrich, D., & Perrin, D. M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200800960 · Cited by 317
Chiang, C.-K., Huang, C.-C., Liu, C.-W., & Chang, H.-T. (2008) · Analytical Chemistry · doi:10.1021/ac800142k · Cited by 307
Responsive reversible hydrogels from associative “smart” macromolecules
Tsitsilianis, C. (2010) · Soft Matter · doi:10.1039/b923947b · Cited by 278
Wegner, S. V., Okesli, A., Chen, P., & He, C. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068342d · Cited by 271
Liu, S., Nie, H., Jiang, J., Shen, G., & Yu, R. (2009) · Analytical Chemistry · doi:10.1021/ac900527f · Cited by 259
Hydrogel formation via hybridization of oligonucleotides derivatized in water-soluble vinyl polymers
Nagahara, S., & Matsuda, T. (1996) · Polymer Gels and Networks · doi:10.1016/0966-7822(96)00001-9 · Cited by 251
Li, N., Bai, R., & Liu, C. (2005) · Langmuir · doi:10.1021/la051551b · Cited by 250
Polydiacetylene–Liposome Microarrays for Selective and Sensitive Mercury(II) Detection
Lee, J., Jun, H., & Kim, J. (2009) · Advanced Materials · doi:10.1002/adma.200900639 · Cited by 213
DNA-Responsive Hydrogels That Can Shrink or Swell
Murakami, Y., & Maeda, M. (2005) · Biomacromolecules · doi:10.1021/bm0504330 · Cited by 211
Arsenic Removal from Vietnamese Groundwater Using the Arsenic-Binding DNA Aptamer
Kim, M., Um, H.-J., Bang, S., Lee, S.-H., Oh, S.-J., Han, J.-H., Kim, K.-W., Min, J., & Kim, Y.-H. (2009) · Environmental Science & Technology · doi:10.1021/es902407g · Cited by 174
Wu, D.-H., Zhang, Q., Chu, X., et al. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.017 · Cited by 165
Controlled Trapping and Release of Quantum Dots in a DNA‐Switchable Hydrogel
Liedl, T., Dietz, H., Yurke, B., & Simmel, F. C. (2007) · Small · doi:10.1002/smll.200700366 · Cited by 150
Early (in uterus and infant) exposure to mercury and lead
Dórea, J. G., & Donangelo, C. M. (2005) · Clinical Nutrition · doi:10.1016/j.clnu.2005.10.007 · Cited by 139
A Mesoporous 3D Hybrid Material with Dual Functionality for Hg2+ Detection and Adsorption
Ros‐Lis, J. V., Casasús, R., Comes, M., Coll, C., Marcos, M. D., Martínez‐Máñez, R., Sancenón, F., Soto, J., Amorós, P., Haskouri, J. E., et al. (2008) · Chemistry - A European Journal · doi:10.1002/chem.200800632 · Cited by 125
Park, M., Seo, S., Lee, I. S., & Jung, J. H. (2010) · Chemical Communications · doi:10.1039/c002905j · Cited by 97
Fluorescent DNA–poly(phenylenevinylene) hybrid hydrogels for monitoring drug release
Tang, H., Duan, X., Feng, X., Liu, L., Wang, S., Li, Y., & Zhu, D. (2008) · Chemical Communications · doi:10.1039/b817788k · Cited by 85
DNA Hydrogel Fiber with Self‐Entanglement Prepared by Using an Ionic Liquid
Lee, C. K., Shin, S. R., Lee, S. H., Jeon, J., So, I., Kang, T. M., Kim, S. I., Mun, J. Y., Han, S., Spinks, G. M., et al. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704600 · Cited by 62
Sönmez, H. B., Şenkal, B. F., Sherrington, D. C., & Bıçak, N. (2003) · Reactive and Functional Polymers · doi:10.1016/s1381-5148(02)00193-1 · Cited by 61
Tierney, S., & Stokke, B. T. (2009) · Biomacromolecules · doi:10.1021/bm900218c · Cited by 47
Nucleic Acid Therapeutic Carriers with On-Demand Triggered Release
Venkatesh, S., Wower, J., & Byrne, M. E. (2009) · Bioconjugate Chemistry · doi:10.1021/bc900187b · Cited by 20
Cited by
Aptamer-integrated DNA nanostructures for biosensing, bioimaging and cancer therapy
Meng, H.-M., Liu, H., Kuai, H., Peng, R., Mo, L., & Zhang, X.-B. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00645g · Cited by 608
Ai, K., Ruan, C., Shen, M., & Lu, L. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201601338 · Cited by 441
Li, C., Faulkner‐Jones, A., Dun, A. R., Jin, J., Chen, P., Xing, Y., Yang, Z., Li, Z., Shu, W., Liu, D., et al. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411383 · Cited by 423
Döring, A., Birnbaum, W., & Kuckling, D. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60031a · Cited by 391
Polymeric DNA hydrogel: Design, synthesis and applications
Li, F., Tang, J., Geng, J., Luo, D., & Yang, D. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.101163 · Cited by 308
Metadata
- Authors
- Dave, N., Chan, M. Y., Huang, P.-J. J., Smith, B. D., & Liu, J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-08-20
- Volume
- 132
- Issue
- 36
- Pages
- 12668-12673
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1973695166
- Cited by
- 461
- References
- 46
- FWCI
- 11.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.