Ion-Exchangeable Cobalt Polysulfide Chalcogel
The DOI matches its Crossref record.
Abstract
We present a promising approach in synthetic chalcogel chemistry that is extendable to a broad variety of inorganic spacers. Polychalcogenide aerogels with ion-exchange properties are demonstrated in cobalt polysulfide. The new materials show a broad range of pore sizes and high surface area of 483 m(2)/g.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gao, M.-R., Xu, Y.-F., Jiang, J., & Yu, S.-H. (2013) · Chemical Society Reviews · doi:10.1039/c2cs35310e · Cited by 1,610
Staszak-Jirkovský, J., Malliakas, C. D., Lopes, P. P., Danilovic, N., Kota, S. S., Chang, K.-C., Genorio, B., Strmcnik, D., Stamenkovic, V. R., Kanatzidis, M. G., et al. (2016) · Nature Materials · doi:10.1038/nmat4481 · Cited by 954
Self-citationEffects of sediment geochemical properties on heavy metal bioavailability
Zhang, C., Yu, Z.-G., Zeng, G.-M., Jiang, M., Yang, Z.-Z., Cui, F., Zhu, M.-Y., Shen, L.-Q., & Hu, L. (2014) · Environment International · doi:10.1016/j.envint.2014.08.010 · Cited by 909
Removal of heavy metal ions from aqueous system by ion-exchange and biosorption methods
Bashir, A., Malik, L. A., Ahad, S., Manzoor, T., Bhat, M. A., Dar, G. N., & Pandith, A. H. (2019) · Environmental Chemistry Letters · doi:10.1007/s10311-018-00828-y · Cited by 737
Ma, L., Wang, Q., Islam, S. M., Liu, Y., Ma, S., & Kanatzidis, M. G. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b00110 · Cited by 705
Self-citationSelective anion exchange with nanogated isoreticular positive metal-organic frameworks
Zhao, X., Bu, X., Wu, T., Zheng, S.-T., Wang, L., & Feng, P. (2013) · Nature Communications · doi:10.1038/ncomms3344 · Cited by 370
Manos, M. J., & Kanatzidis, M. G. (2016) · Chemical Science · doi:10.1039/c6sc01039c · Cited by 334
Self-citationChalcogenide Aerogels as Sorbents for Radioactive Iodine
Subrahmanyam, K. S., Sarma, D., Malliakas, C. D., Polychronopoulou, K., Riley, B. J., Pierce, D. A., Chun, J., & Kanatzidis, M. G. (2015) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b00413 · Cited by 275
Self-citationSubrahmanyam, K. S., Malliakas, C. D., Sarma, D., Armatas, G. S., Wu, J., & Kanatzidis, M. G. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b09110 · Cited by 193
Self-citationSynthesis of aerogels: from molecular routes to 3-dimensional nanoparticle assembly
Rechberger, F., & Niederberger, M. (2017) · Nanoscale Horizons · doi:10.1039/c6nh00077k · Cited by 148
Gao, Q., Wang, X., Shi, Z., Ye, Z., Wang, W., Zhang, N., Hong, Z., & Zhi, M. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.08.067 · Cited by 114
Preparation of porous MoS2 via a sol–gel route using (NH4)2Mo3S13 as precursor
Li, N., Chai, Y., Dong, B., Liu, B., Guo, H., & Liu, C. (2012) · Materials Letters · doi:10.1016/j.matlet.2012.08.031 · Cited by 25
Engineering of Aerogel-Based Electrocatalysts for Oxygen Evolution Reaction
Gao, C., Zhang, X., Zhan, J., & Cai, B. (2022) · Electrochemical Science Advances · doi:10.1002/elsa.202100113 · Cited by 15
Metadata
- Authors
- Shafaei-Fallah, M., He, J., Rothenberger, A., & Kanatzidis, M. G.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-01-07
- Volume
- 133
- Issue
- 5
- Pages
- 1200-1202
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2321770011
- Cited by
- 55
- References
- 0
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.