The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Sensitive and Selective Amplified Fluorescence DNA Detection Based on Exonuclease III-Aided Target Recycling
Abstract
A limitation of many traditional approaches to the detection of specific oligonucleotide sequences, such as molecular beacons, is that each target strand hybridizes with (and thus activates) only a single copy of the relevant probe sequence. This 1:1 hybridization ratio limits the gain of most approaches and thus their sensitivity. Here we demonstrate a nuclease-amplified DNA detection scheme in which exonuclease III is used to "recycle" target molecules, thus leading to greatly improved sensitivity relative to, for example, traditional molecular beacons without any significant restriction in the choice of target sequences. The exonuclease-amplified assay can detect target DNA at concentrations as low as 10 pM when performed at 37 degrees C, which represents a significant improvement over the equivalent molecular beacon alone. Moreover, at 4 degrees C we can obtain a detection limit as low as 20 aM, albeit at the cost of a 24 h incubation period. Finally, our assay can be easily interrogated with the naked eye and is thus amenable to deployment in the developing world, where fluorometric detection is more problematic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heid, C. A., Stevens, J., Livak, K. J., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.986 · Cited by 6,174
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Unidirectional digestion with exonuclease III creates targeted breakpoints for DNA sequencing
Henikoff, S. (1984) · Gene · doi:10.1016/0378-1119(84)90153-7 · Cited by 4,145
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Nanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,035
Li, H., & Rothberg, L. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406115101 · Cited by 1,342
Multicolor molecular beacons for allele discrimination
Tyagi, S., Bratu, D. P., & Kramer, F. R. (1998) · Nature Biotechnology · doi:10.1038/nbt0198-49 · Cited by 1,320
Bio-Bar-Code-Based DNA Detection with PCR-like Sensitivity
Nam, J.-M., Stoeva, S. I., & Mirkin, C. A. (2004) · Journal of the American Chemical Society · doi:10.1021/ja049384+ · Cited by 744
A gold nanoparticle-based chronocoulometric DNA sensor for amplified detection of DNA
Zhang, J., Song, S., Wang, L., Pan, D., & Fan, C. (2007) · Nature Protocols · doi:10.1038/nprot.2007.419 · Cited by 473
Xia, Y., Xiong, Y., Lim, B., & Skrabalak, S. E. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200890275 · Cited by 442
Cited by
Isothermal Amplification of Nucleic Acids
Zhao, Y., Chen, F., Li, Q., Wang, L., & Fan, C. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00428 · Cited by 1,775
Wang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Isothermal amplified detection of DNA and RNA
Yan, L., Zhou, J., Zheng, Y., Gamson, A. S., Roembke, B. T., Nakayama, S., & Sintim, H. O. (2014) · Molecular BioSystems · doi:10.1039/c3mb70304e · Cited by 446
DNA-Mediated Homogeneous Binding Assays for Nucleic Acids and Proteins
Zhang, H., Li, F., Dever, B., Li, X.-F., & Le, X. C. (2013) · Chemical Reviews · doi:10.1021/cr300340p · Cited by 415
Duan, R., Zuo, X., Wang, S., Quan, X., Chen, D., Chen, Z., Jiang, L., Fan, C., & Xia, F. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311313b · Cited by 355
Self-citationAmplified Analysis of DNA by the Autonomous Assembly of Polymers Consisting of DNAzyme Wires
Wang, F., Elbaz, J., Orbach, R., Magen, N., & Willner, I. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2076789 · Cited by 339
Recent advances in DNA-based electrochemical biosensors for heavy metal ion detection: A review
Saidur, M. R., Aziz, A. R. A., & Basirun, W. J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.11.039 · Cited by 339
Detection and beyond: challenges and advances in aptamer-based biosensors
Yoo, H., Jo, H., & Oh, S. S. (2020) · Materials Advances · doi:10.1039/d0ma00639d · Cited by 334
A CRISPR-Cas autocatalysis-driven feedback amplification network for supersensitive DNA diagnostics
Shi, K., Xie, S., Tian, R., Wang, S., Lu, Q., Gao, D., Lei, C., Zhu, H., & Nie, Z. (2021) · Science Advances · doi:10.1126/sciadv.abc7802 · Cited by 334
Rationally Engineered Nucleic Acid Architectures for Biosensing Applications
Xiao, M., Lai, W., Man, T., Chang, B., Li, L., Chandrasekaran, A. R., & Pei, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00121 · Cited by 290
Smartphone Fluorescence Spectroscopy
Yu, H., Tan, Y., & Cunningham, B. T. (2014) · Analytical Chemistry · doi:10.1021/ac502080t · Cited by 281
Wang, Q., Wang, W., Lei, J., Xu, N., Gao, F., & Ju, H. (2013) · Analytical Chemistry · doi:10.1021/ac403646n · Cited by 266
Nucleic Acid Tests for Clinical Translation
Li, M., Yin, F., Song, L., Mao, X., Li, F., Fan, C., Zuo, X., & Xia, Q. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00241 · Cited by 264
Self-citationLeng, Y., Sun, K., Chen, X., & Li, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00382a · Cited by 258
Metadata
- Authors
- Zuo, X., Xia, F., Xiao, Y., & Plaxco, K. W.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-01-21
- Volume
- 132
- Issue
- 6
- Pages
- 1816-1818
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1991453437
- Cited by
- 497
- References
- 20
- FWCI
- 16.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.