The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Nanoscale Optical Biosensor: Real-Time Immunoassay in Physiological Buffer Enabled by Improved Nanoparticle Adhesion
Abstract
The shift in the extinction maximum, λ max, of the localized surface plasmon resonance (LSPR) spectrum of triangular Ag nanoparticles (∼90 nm wide and 50 nm high) is used to probe the interaction between a surface-confined antigen, biotin (B), and a solution-phase antibody, anti-biotin (AB). Exposure of biotin-functionalized Ag nanotriangles to 7 × 10 -7 M < [AB] < 7 × 10 -6 M caused a ∼38 nm red-shift in the LSPR λ max . The experimental normalized response of the LSPR λ max shift, (Δ R /Δ R max ), versus [AB] was measured over the concentration range 7 × 10 -10 M < [AB] < 7 × 10 -6 M. Comparison of the experimental data with the theoretical normalized response for a 1:1 binding model yielded values for the saturation response, Δ R max = 38.0 nm, the surface-confined thermodynamic binding constant, K a,surf = 4.5 × 10 7 M -1, and the limit of detection (LOD) < 7 × 10 -10 M. The experimental saturation response was interpreted in terms of a closest-packed structural model for the surface B−AB complex in which the long axis of AB, l AB = 15 nm, is oriented horizontally and the short axis, h AB = 4 nm is oriented vertically to the nanoparticle surface. This model yields a quantitative response for the saturation response, Δ R max = 40.6 nm, in good agreement with experiment, Δ R max = 38.0 nm. An atomic force microscopy (AFM) study supports this interpretation. In addition, major improvements in the LSPR nanobiosensor are reported. The LSPR nanobiosensor substrate was changed from glass to mica, and a surfactant, Triton X-100, was used in the nanosphere lithography fabrication procedure. These changes increased the adhesion of the Ag nanotriangles by a factor of 9 as determined by AFM normal force studies. The improved adhesion of Ag nanotriangles now enables the study of the B−AB immunoassay in a physiologically relevant fluid environment as well as in real-time. These results represent important new steps in the development of the LSPR nanosensor for applications in medical diagnostics, biomedical research, and environmental science.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perspectives on the Physical Chemistry of Semiconductor Nanocrystals
Alivisatos, A. P. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp9535506 · Cited by 3,595
Haes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
Self-citation
Cited by
Self-Assembled Monolayers of Thiolates on Metals as a Form of Nanotechnology
Love, J. C., Estroff, L. A., Kriebel, J. K., Nuzzo, R. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr0300789 · Cited by 8,282
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Jain, P. K., Lee, K. S., El-Sayed, I. H., & El-Sayed, M. A. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp057170o · Cited by 4,603
Localized Surface Plasmon Resonance Sensors
Mayer, K. M., & Hafner, J. H. (2011) · Chemical Reviews · doi:10.1021/cr100313v · Cited by 4,350
Exploitation of Localized Surface Plasmon Resonance
Hutter, E., & Fendler, J. H. (2004) · Advanced Materials · doi:10.1002/adma.200400271 · Cited by 2,726
Integrated Nanoparticle–Biomolecule Hybrid Systems: Synthesis, Properties, and Applications
Katz, E., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200400651 · Cited by 2,450
Nanostructured Plasmonic Sensors
Stewart, M. E., Anderton, C. R., Thompson, L. B., Maria, J., Gray, S. K., Rogers, J. A., & Nuzzo, R. G. (2008) · Chemical Reviews · doi:10.1021/cr068126n · Cited by 2,415
Gold nanoparticles in biomedical applications: recent advances and perspectives
Dykman, L., & Khlebtsov, N. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15166e · Cited by 1,961
Single Silver Nanoparticles as Real-Time Optical Sensors with Zeptomole Sensitivity
McFarland, A. D., & Van Duyne, R. P. (2003) · Nano Letters · doi:10.1021/nl034372s · Cited by 1,626
Self-citationShape- and Size-Dependent Refractive Index Sensitivity of Gold Nanoparticles
Chen, H., Kou, X., Yang, Z., Ni, W., & Wang, J. (2008) · Langmuir · doi:10.1021/la800305j · Cited by 1,334
Wavelength-Scanned Surface-Enhanced Raman Excitation Spectroscopy
McFarland, A. D., Young, M. A., Dieringer, J. A., & Van Duyne, R. P. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp050508u · Cited by 959
Self-citationHaes, A. J., Chang, L., Klein, W. L., & Van Duyne, R. P. (2005) · Journal of the American Chemical Society · doi:10.1021/ja044087q · Cited by 864
Self-citationToxicity of Metal Oxide Nanoparticles in Mammalian Cells
JENG, H. A., & SWANSON, J. (2006) · Journal of Environmental Science and Health, Part A · doi:10.1080/10934520600966177 · Cited by 785
Electroanalytical and Bioelectroanalytical Systems Based on Metal and Semiconductor Nanoparticles
Katz, E., Willner, I., & Wang, J. (2004) · Electroanalysis · doi:10.1002/elan.200302930 · Cited by 738
Rational and Combinatorial Design of Peptide Capping Ligands for Gold Nanoparticles
Lévy, R., Thanh, N. T. K., Doty, R. C., Hussain, I., Nichols, R. J., Schiffrin, D. J., Brust, M., & Fernig, D. G. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0487269 · Cited by 724
Biomolecular Recognition Based on Single Gold Nanoparticle Light Scattering
Raschke, G., Kowarik, S., Franzl, T., Sönnichsen, C., Klar, T. A., Feldmann, J., Nichtl, A., & Kürzinger, K. (2003) · Nano Letters · doi:10.1021/nl034223+ · Cited by 716
A Localized Surface Plasmon Resonance Biosensor: First Steps toward an Assay for Alzheimer's Disease
Haes, A. J., Hall, W. P., Chang, L., Klein, W. L., & Van Duyne, R. P. (2004) · Nano Letters · doi:10.1021/nl049670j · Cited by 710
Self-citationA unified view of propagating and localized surface plasmon resonance biosensors
Haes, A. J., & Van Duyne, R. P. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2708-9 · Cited by 666
Self-citationNath, N., & Chilkoti, A. (2004) · Analytical Chemistry · doi:10.1021/ac049741z · Cited by 514
Localized Surface Plasmon Resonance Biosensors
Zhao, J., Zhang, X., Yonzon, C. R., Haes, A. J., & Van Duyne, R. P. (2006) · Nanomedicine · doi:10.2217/17435889.1.2.219 · Cited by 508
Self-citationYonzon, C. R., Jeoung, E., Zou, S., Schatz, G. C., Mrksich, M., & Van Duyne, R. P. (2004) · Journal of the American Chemical Society · doi:10.1021/ja047118q · Cited by 494
Self-citationA Label-Free Immunoassay Based Upon Localized Surface Plasmon Resonance of Gold Nanorods
Mayer, K. M., Lee, S., Liao, H., Rostro, B. C., Fuentes, A., Scully, P. T., Nehl, C. L., & Hafner, J. H. (2008) · ACS Nano · doi:10.1021/nn7003734 · Cited by 463
Surface plasmon resonance based biosensor technique: A review
Guo, X. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200015 · Cited by 436
Colloidal silver nanoplates. State of the art and future challenges
Pastoriza-Santos, I., & Liz-Marzán, L. M. (2008) · Journal of Materials Chemistry · doi:10.1039/b716538b · Cited by 405
Allahverdiyev, A. M., Abamor, E. S., Bagirova, M., & Rafailovich, M. (2011) · Future Microbiology · doi:10.2217/fmb.11.78 · Cited by 396
Nanosensors in environmental analysis
RIU, J., MAROTO, A., & RIUS, F. (2006) · Talanta · doi:10.1016/j.talanta.2005.09.045 · Cited by 363
Kora, A. J., Sashidhar, R. B., & Arunachalam, J. (2010) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2010.05.034 · Cited by 328
Sensing using localised surface plasmon resonance sensors
Szunerits, S., & Boukherroub, R. (2012) · Chemical Communications · doi:10.1039/c2cc33266c · Cited by 318
Nanoparticle labels in immunosensing using optical detection methods
Seydack, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.003 · Cited by 314
Enzyme Colorimetric Assay Using Unmodified Silver Nanoparticles
Wei, H., Chen, C., Han, B., & Wang, E. (2008) · Analytical Chemistry · doi:10.1021/ac801144t · Cited by 314
Whitney, A. V., Elam, J. W., Zou, S., Zinovev, A. V., Stair, P. C., Schatz, G. C., & Van Duyne, R. P. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp0540656 · Cited by 310
Self-citationBiological applications of localised surface plasmonic phenomenae
Stuart, D. A., Haes, A. J., Yonzon, C. R., Hicks, E. M., & Van Duyne, R. P. (2005) · IEE Proceedings - Nanobiotechnology · doi:10.1049/ip-nbt:20045012 · Cited by 283
Self-citationKatz, E., & Willner, I. (2004) · Angewandte Chemie · doi:10.1002/ange.200400651 · Cited by 260
Metadata
- Authors
- Riboh, J. C., Haes, A. J., McFarland, A. D., Ranjit Yonzon, C., & Van Duyne, R. P.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-01-29
- Volume
- 107
- Issue
- 8
- Pages
- 1772-1780
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2078325166
- Cited by
- 475
- References
- 2
- FWCI
- 18.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.