The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Microfluidic Multicompartment Device for Neuroscience Research
Open accessAbstract
This paper describes and characterizes a novel microfabricated neuronal culture device. This device combines microfabrication, microfluidic, and surface micropatterning techniques to create a multicompartment neuronal culturing device that can be used in a number of neuroscience research applications. The device is fabricated in poly(dimethylsiloxane), PDMS, using soft lithography techniques. The PDMS device is placed on a tissue culture dish (polystyrene) or glass substrate, forming two compartments with volumes of less than 2 μL each. These two compartments are separated by a physical barrier in which a number of micron-size grooves are embedded to allow growth of neurites across the compartments while maintaining fluidic isolation. Cells are plated into the somal (cell body) compartment, and after 3-4 days, neurites extend into the neuritic compartment via the grooves. Viability of the neurons in the devices is between 50 and 70% after 7 days in culture; this is slightly lower than but comparable to values for a control grown on tissue culture dishes. Healthy neuron morphology is evident in both the devices and controls. We demonstrate the ability to use hydrostatic pressure to isolate insults to one compartment and, thus, expose localized areas of neurons to insults applied in soluble form. Due to the high resistance of the microgrooves for fluid transport, insults are contained in the neuritic compartment without appreciable leakage into the somal compartment for over 15 h. Finally, we demonstrate the use of polylysine patterning in combination with the microfabricated device to facilitate identification and visualization of neurons. The ability to direct sites of neuronal attachment and orientation of neurite outgrowth by micropatterning techniques, combined with fluidically isolated compartments within the culture area, offers significant advantages over standard open culture methods and other conventional methods for manipulating distinct neuronal microenvironments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Local control of neurite development by nerve growth factor
Campenot, R. B. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.10.4516 · Cited by 746
Vesa, J., Hellsten, E., Verkruyse, L. A., Camp, L. A., Rapola, J., Santavuori, P., Hofmann, S. L., & Peltonen, L. (1995) · Nature · doi:10.1038/376584a0 · Cited by 737
Self-Complementarity Achieved through Quadruple Hydrogen Bonding
Beijer, F. H., Kooijman, H., Spek, A. L., Sijbesma, R. P., & Meijer, E. W. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980202)37:1/2<75::aid-anie75>3.0.co;2-r · Cited by 320
Development of sympathetic neurons in compartmentalized cultures
Campenot, R. B. (1982) · Developmental Biology · doi:10.1016/0012-1606(82)90232-9 · Cited by 192
Ivins, K. J., Bui, E. T. N., & Cotman, C. W. (1998) · Neurobiology of Disease · doi:10.1006/nbdi.1998.0228 · Cited by 164
Self-citation
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
A microfluidic culture platform for CNS axonal injury, regeneration and transport
Taylor, A. M., Blurton-Jones, M., Rhee, S. W., Cribbs, D. H., Cotman, C. W., & Jeon, N. L. (2005) · Nature Methods · doi:10.1038/nmeth777 · Cited by 1,153
Self-citationAbgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Microfluidic culture platform for neuroscience research
Park, J. W., Vahidi, B., Taylor, A. M., Rhee, S. W., & Jeon, N. L. (2006) · Nature Protocols · doi:10.1038/nprot.2006.316 · Cited by 464
Self-citationBiosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
Waldbaur, A., Rapp, H., Länge, K., & Rapp, B. E. (2011) · Analytical Methods · doi:10.1039/c1ay05253e · Cited by 381
Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Faustino, V., Catarino, S. O., Lima, R., & Minas, G. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.031 · Cited by 338
Axonal mRNA in Uninjured and Regenerating Cortical Mammalian Axons
Taylor, A. M., Berchtold, N. C., Perreau, V. M., Tu, C. H., Li Jeon, N., & Cotman, C. W. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.6130-08.2009 · Cited by 328
Self-citationDanzer, K. M., Ruf, W. P., Putcha, P., Joyner, D., Hashimoto, T., Glabe, C., Hyman, B. T., & McLean, P. J. (2011) · The FASEB Journal · doi:10.1096/fj.10-164624 · Cited by 312
Exosomes Derived from Mesenchymal Stromal Cells Promote Axonal Growth of Cortical Neurons
Zhang, Y., Chopp, M., Liu, X. S., Katakowski, M., Wang, X., Tian, X., Wu, D., & Zhang, Z. G. (2017) · Molecular Neurobiology · doi:10.1007/s12035-016-9851-0 · Cited by 300
Microfluidic Local Perfusion Chambers for the Visualization and Manipulation of Synapses
Taylor, A. M., Dieterich, D. C., Ito, H. T., Kim, S. A., & Schuman, E. M. (2010) · Neuron · doi:10.1016/j.neuron.2010.03.022 · Cited by 292
Self-citationSutton, M. A., Taylor, A. M., Ito, H. T., Pham, A., & Schuman, E. M. (2007) · Neuron · doi:10.1016/j.neuron.2007.07.030 · Cited by 274
Self-citationMicrofluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
Bridging the gap: microfluidic devices for short and long distance cell–cell communication
Vu, T. Q., de Castro, R. M. B., & Qin, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01367h · Cited by 63
Tau misfolding efficiently propagates between individual intact hippocampal neurons
Hallinan, G. I., Vargas-Caballero, M., West, J., & Deinhardt, K. (2019) · The Journal of Neuroscience · doi:10.1523/jneurosci.1590-19.2019 · Cited by 59
Axonal Terminals Exposed to Amyloid-β May Not Lead to Pre-Synaptic Axonal Damage
Sun, S.-W., Nishioka, C., Labib, W., & Liang, H.-F. (2015) · Journal of Alzheimer’s Disease · doi:10.3233/jad-142154 · Cited by 8
Metadata
- Authors
- Taylor, A. M., Rhee, S. W., Tu, C. H., Cribbs, D. H., Cotman, C. W., & Jeon, N. L.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-12-04
- Volume
- 19
- Issue
- 5
- Pages
- 1551-1556
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W4249587697
- Cited by
- 295
- References
- 6
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.