Cited by 59Neuroscience and Neural EngineeringElectrochemical Analysis and ApplicationsElectrochemical sensors and biosensors

Investigating the interfacial properties of electrochemically roughened platinum electrodes for neural stimulation

Weremfo, Alexander, Carter, Paul, Hibbert, D. Brynn, Zhao, Chuan·2015·Langmuir

Abstract

Platinum electrodes have been electrochemically roughened (roughness factors up to 430) and evaluated for use as neural stimulation electrodes. The roughened electrodes show superior interfacial properties with increasing surface roughness. The roughened electrode (fR = 250) has a charge injection limit of 1.0 mC cm(-2) (400 μs pulse width), which is superior to that of titanium nitride (0.87 mC cm(-2)) but comparable to that of carbon nanotubes (1.0-1.6 mC cm(-2)). The surface roughness can also be optimized for different neural stimulation applications based on the available charge density at a particular pulse width of stimulation. The roughened platinum electrodes demonstrated good mechanical stability under harsh ultrasonication and electrochemical stability under continuous biphasic stimulation, indicating the potential of this biological interface to be safe and stable.

Integrity signals

Registry

Crossref · 10.1021/la504876n

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Weremfo, A., Carter, P., Hibbert, D. B., & Zhao, C.
Affiliations
  • UNSW Sydney (AU)
  • Cochlear (Australia) (AU)
Corresponding author
  • Carter, Paul
  • Hibbert, D. Brynn
  • Zhao, Chuan
Venue
Langmuir
Published
2015-02-19
Volume
31
Issue
8
Pages
2593-2599
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2334119338
Cited by
59
References
33
Citations by year
2026: 4 · 2025: 7 · 2024: 4 · 2023: 3 · 2022: 5 · 2021: 4 · 2020: 5 · 2019: 12 · 2018: 5 · 2017: 5 · 2016: 3 · 2015: 2
FWCI
2.32
Type
journal article
Language
en
Open access
closed
Locations
  • Langmuir (publishedVersion)
  • PubMed (publishedVersion)
Funders
Australian Research Council (DP110102569, LP100200770)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
Keywords
platinum electrode, neural stimulation electrodes, electrode-electrolyte interface, charge injection limit, surface roughness, titanium nitride electrodes, carbon nanotube electrodes, biphasic stimulation, mechanical stability, sonication, electrochemical stability, biointerfaces
MeSH terms
Electrodes, Particle Size, Platinum, Surface Properties, Electrochemical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review