The DOI matches its Crossref record.
Digital Concentration Readout of Single Enzyme Molecules Using Femtoliter Arrays and Poisson Statistics
Abstract
Methods for accurately quantifying the concentration of a particular analyte in solution are all based on ensemble responses in which many analyte molecules give rise to the measured signal. In this paper, single molecules of beta-galactosidase were monitored using a 1 mm diameter fiber optic bundle with 2.4 x 10(5) individually sealed, femtoliter microwell reactors. By observation of the buildup of fluorescent products from single enzyme molecule catalysis over the array of reaction vessels and by application of a Poisson statistical analysis, a digital concentration readout was obtained. This approach should prove useful for single molecule enzymology and ultrasensitive bioassays. More generally, the ability to determine concentration by counting individual molecules offers a new approach to analysis of dilute solutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Self-citationOptical sensor arrays for chemical sensing: the optoelectronic nose
Askim, J. R., Mahmoudi, M., & Suslick, K. S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60179j · Cited by 886
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2008) · Analytical Chemistry · doi:10.1021/ac800473b · Cited by 571
Neurofilaments as biomarkers in neurological disorders — towards clinical application
Khalil, M., Teunissen, C. E., Lehmann, S., Otto, M., Piehl, F., Ziemssen, T., Bittner, S., Sormani, M. P., Gattringer, T., Abu-Rumeileh, S., et al. (2024) · Nature Reviews Neurology · doi:10.1038/s41582-024-00955-x · Cited by 446
Electrolyte-gated transistors for enhanced performance bioelectronics
Torricelli, F., Adrahtas, D. Z., Bao, Z., Berggren, M., Biscarini, F., Bonfiglio, A., Bortolotti, C. A., Frisbie, C. D., Macchia, E., Malliaras, G. G., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00065-8 · Cited by 422
Kelley, S. O., Mirkin, C. A., Walt, D. R., Ismagilov, R. F., Toner, M., & Sargent, E. H. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.261 · Cited by 398
Self-citationSingle‐Molecule Sensors: Challenges and Opportunities for Quantitative Analysis
Gooding, J. J., & Gaus, K. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201600495 · Cited by 340
Boedicker, J. Q., Vincent, M. E., & Ismagilov, R. F. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200901550 · Cited by 327
Digital colloid-enhanced Raman spectroscopy by single-molecule counting
Bi, X., Czajkowsky, D. M., Shao, Z., & Ye, J. (2024) · Nature · doi:10.1038/s41586-024-07218-1 · Cited by 305
Highly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Self-citationCohen, L., Cui, N., Cai, Y., Garden, P. M., Li, X., Weitz, D. A., & Walt, D. R. (2020) · ACS Nano · doi:10.1021/acsnano.0c02378 · Cited by 263
Self-citationReplication of genetic information with self-encoded replicase in liposomes
Kita, H., Matsuura, T., Sunami, T., Hosoda, K., Ichihashi, N., Tsukada, K., Urabe, I., & Yomo, T. (2008) · ChemBioChem · doi:10.1002/cbic.200800360 · Cited by 166
Metadata
- Authors
- Rissin, D. M., & Walt, D. R.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-02-21
- Volume
- 6
- Issue
- 3
- Pages
- 520-523
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W1976045759
- Cited by
- 195
- References
- 0
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.