Nanostraws for Direct Fluidic Intracellular Access
Abstract
Nanomaterials are promising candidates to improve the delivery efficiency and control of active agents such as DNA or drugs directly into cells. Here we demonstrate cell-culture platforms of nanotemplated "nanostraws" that pierce the cell membrane, providing a permanent fluidic pipeline into the cell for direct cytosolic access. Conventional polymeric track-etch cell culture membranes are alumina coated and etched to produce fields of nanostraws with controllable diameter, thickness, and height. Small molecules and ions were successfully transported into the cytosol with 40 and 70% efficiency, respectively, while GFP plasmids were successfully delivered and expressed. These platforms open the way for active, reproducible delivery of a wide variety of species into cells without endocytosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular characterization of mitochondrial apoptosis-inducing factor
Susin, S. A., Lorenzo, H. K., Zamzami, N., Marzo, I., Snow, B. E., Brothers, G. M., Mangion, J., Jacotot, E., Costantini, P., Loeffler, M., et al. (1999) · Nature · doi:10.1038/17135 · Cited by 4,060
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Biodegradable nanoparticles for cytosolic delivery of therapeutics
VASIR, J., & LABHASETWAR, V (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.06.003 · Cited by 526
Zeck, G., & Fromherz, P. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.181348698 · Cited by 290
Multifunctional carbon-nanotube cellular endoscopes.
Singhal, R., Orynbayeva, Z., Kalyana Sundaram, R. V., Niu, J. J., Bhattacharyya, S., Vitol, E. A., Schrlau, M. G., Papazoglou, E. S., Friedman, G., & Gogotsi, Y. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.241 · Cited by 241
Cited by
In vitro and ex vivo strategies for intracellular delivery
Stewart, M. P., Sharei, A., Ding, X., Sahay, G., Langer, R., & Jensen, K. F. (2016) · Nature · doi:10.1038/nature19764 · Cited by 885
Intracellular Delivery by Membrane Disruption: Mechanisms, Strategies, and Concepts
Stewart, M. P., Langer, R., & Jensen, K. F. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00678 · Cited by 747
Three-dimensional nano-biointerface as a new platform for guiding cell fate
Liu, X., & Wang, S. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60419e · Cited by 275
CMOS nanoelectrode array for all-electrical intracellular electrophysiological imaging
Abbott, J., Ye, T., Qin, L., Jorgolli, M., Gertner, R. S., Ham, D., & Park, H. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.3 · Cited by 266
Nanotechnology: emerging tools for biology and medicine
Wong, I. Y., Bhatia, S. N., & Toner, M. (2013) · Genes & Development · doi:10.1101/gad.226837.113 · Cited by 132
Metadata
- Authors
- VanDersarl, J. J., Xu, A. M., & Melosh, N. A.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-12-20
- Volume
- 12
- Issue
- 8
- Pages
- 3881-3886
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2005933611
- Cited by
- 223
- References
- 5
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanostraws for Direct Fluidic Intracellular Access. https://app.cochat.ai/papers/10.1021/nl204051v
- The paper
- VanDersarl, J. J., Xu, A. M., & Melosh, N. A. (2012). Nanostraws for Direct Fluidic Intracellular Access. Nano Letters. https://doi.org/10.1021/nl204051v
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.