The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
LSPR Chip for Parallel, Rapid, and Sensitive Detection of Cancer Markers in Serum
Open accessAbstract
Label-free biosensing based on metallic nanoparticles supporting localized surface plasmon resonances (LSPR) has recently received growing interest (Anker, J. N., et al. Nat. Mater. 2008, 7, 442-453). Besides its competitive sensitivity (Yonzon, C. R., et al. J. Am. Chem. Soc. 2004, 126, 12669-12676; Svendendahl, M., et al. Nano Lett. 2009, 9, 4428-4433) when compared to the surface plasmon resonance (SPR) approach based on extended metal films, LSPR biosensing features a high-end miniaturization potential and a significant reduction of the interrogation device bulkiness, positioning itself as a promising candidate for point-of-care diagnostic and field applications. Here, we present the first, paralleled LSPR lab-on-a-chip realization that goes well beyond the state-of-the-art, by uniting the latest advances in plasmonics, nanofabrication, microfluidics, and surface chemistry. Our system offers parallel, real-time inspection of 32 sensing sites distributed across 8 independent microfluidic channels with very high reproducibility/repeatability. This enables us to test various sensing strategies for the detection of biomolecules. In particular we demonstrate the fast detection of relevant cancer biomarkers (human alpha-feto-protein and prostate specific antigen) down to concentrations of 500 pg/mL in a complex matrix consisting of 50% human serum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Haynes, C. L., & Van Duyne, R. P. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp010657m · Cited by 2,500
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Self-citationCatalona, W. J., Richie, J. P., Ahmann, F. R., Hudson, M. A., Scardino, P. T., Flanigan, R. C., Dekernion, J. B., Ratliff, T. L., Kavoussi, L. R., Dalkin, B. L., et al. (1994) · Journal of Urology · doi:10.1016/s0022-5347(17)35233-3 · Cited by 1,592
Surface Plasmon Resonance Based Sensors
(2006) · Springer Series on Chemical Sensors and Biosensors · doi:10.1007/b100321 · Cited by 1,424
Plasmonic ELISA for the ultrasensitive detection of disease biomarkers with the naked eye
de la Rica, R., & Stevens, M. M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.186 · Cited by 873
Zijlstra, P., Paulo, P. M. R., & Orrit, M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.51 · Cited by 788
Fano Resonances in Plasmonic Nanoclusters: Geometrical and Chemical Tunability
Lassiter, J. B., Sobhani, H., Fan, J. A., Kundu, J., Capasso, F., Nordlander, P., & Halas, N. J. (2010) · Nano Letters · doi:10.1021/nl102108u · Cited by 632
Hole–Mask Colloidal Lithography
Fredriksson, H., Alaverdyan, Y., Dmitriev, A., Langhammer, C., Sutherland, D. S., Zäch, M., & Kasemo, B. (2007) · Advanced Materials · doi:10.1002/adma.200700680 · Cited by 564
Yonzon, C. R., Jeoung, E., Zou, S., Schatz, G. C., Mrksich, M., & Van Duyne, R. P. (2004) · Journal of the American Chemical Society · doi:10.1021/ja047118q · Cited by 494
Plasmonic nanosensors with inverse sensitivity by means of enzyme-guided crystal growth
Rodríguez-Lorenzo, L., de la Rica, R., Álvarez-Puebla, R. A., Liz-Marzán, L. M., & Stevens, M. M. (2012) · Nature Materials · doi:10.1038/nmat3337 · Cited by 443
Surface plasmons on smooth surfaces
Raether, H. (1988) · Springer Tracts in Modern Physics · doi:10.1007/bfb0048319 · Cited by 410
Plasmon Near-Field Coupling in Metal Dimers as a Step toward Single-Molecule Sensing
Aćimović, S. S., Kreuzer, M. P., González, M. U., & Quidant, R. (2009) · ACS Nano · doi:10.1021/nn900102j · Cited by 361
Self-citationRefractometric Sensing Using Propagating versus Localized Surface Plasmons: A Direct Comparison
Svedendahl, M., Chen, S., Dmitriev, A., & Käll, M. (2009) · Nano Letters · doi:10.1021/nl902721z · Cited by 351
Single Unlabeled Protein Detection on Individual Plasmonic Nanoparticles
Ament, I., Prasad, J., Henkel, A., Schmachtel, S., & Sönnichsen, C. (2012) · Nano Letters · doi:10.1021/nl204496g · Cited by 335
Improving the Instrumental Resolution of Sensors Based on Localized Surface Plasmon Resonance
Dahlin, A. B., Tegenfeldt, J. O., & Höök, F. (2006) · Analytical Chemistry · doi:10.1021/ac0601967 · Cited by 329
Lee, S.-W., Lee, K.-S., Ahn, J., Lee, J.-J., Kim, M.-G., & Shin, Y.-B. (2011) · ACS Nano · doi:10.1021/nn102041m · Cited by 300
Noble Metal Nanoparticle Pairs: Effect of Medium for Enhanced Nanosensing
Jain, P. K., & El-Sayed, M. A. (2008) · Nano Letters · doi:10.1021/nl8021835 · Cited by 291
Nanoholes As Nanochannels: Flow-through Plasmonic Sensing
Eftekhari, F., Escobedo, C., Ferreira, J., Duan, X., Girotto, E. M., Brolo, A. G., Gordon, R., & Sinton, D. (2009) · Analytical Chemistry · doi:10.1021/ac900221y · Cited by 290
Gold Nanoshells Improve Single Nanoparticle Molecular Sensors
Raschke, G., Brogl, S., Susha, A. S., Rogach, A. L., Klar, T. A., Feldmann, J., Fieres, B., Petkov, N., Bein, T., Nichtl, A., et al. (2004) · Nano Letters · doi:10.1021/nl049038q · Cited by 261
Tam, F., Moran, C., & Halas, N. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp048499x · Cited by 243
Current Status of Biomarkers for Prostate Cancer
Velonas, V., Woo, H., Remedios, C., & Assinder, S. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140611034 · Cited by 216
Plasmon-Enhanced Colorimetric ELISA with Single Molecule Sensitivity
Chen, S., Svedendahl, M., Van Duyne, R. P., & Käll, M. (2011) · Nano Letters · doi:10.1021/nl2006092 · Cited by 186
Chen, S., Svedendahl, M., Käll, M., Gunnarsson, L., & Dmitriev, A. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/43/434015 · Cited by 160
Locally Functionalized Short-Range Ordered Nanoplasmonic Pores for Bioanalytical Sensing
Jonsson, M. P., Dahlin, A., Feuz, L., Petronis, Š., & Höök, F. (2010) · Analytical Chemistry · doi:10.1021/ac902925e · Cited by 108
High Throughput Single Nanoparticle Spectroscopy
Sebba, D. S., Watson, D. A., & Nolan, J. P. (2009) · ACS Nano · doi:10.1021/nn9003346 · Cited by 59
A 1024-sample serum analyzer chip for cancer diagnostics
Garcia-Cordero, J. L., & Maerkl, S. J. (2013) · Lab on a Chip · doi:10.1039/c3lc51153g · Cited by 47
Self-citation
Cited by
Plasmonic Biosensing: Focus Review
Mejía-Salazar, J. R., & Oliveira, O. N. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00359 · Cited by 544
Various methods of gold nanoparticles (GNPs) conjugation to antibodies
Jazayeri, M. H., Amani, H., Pourfatollah, A. A., Pazoki-Toroudi, H., & Sedighimoghaddam, B. (2016) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2016.04.002 · Cited by 528
Integrating Artificial Intelligence and Nanotechnology for Precision Cancer Medicine
Adir, O., Poley, M., Chen, G., Froim, S., Krinsky, N., Shklover, J., Shainsky‐Roitman, J., Lammers, T., & Schroeder, A. (2020) · Advanced Materials · doi:10.1002/adma.201901989 · Cited by 496
Nanoplasmonic sensors for biointerfacial science
Jackman, J. A., Rahim Ferhan, A., & Cho, N.-J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00494f · Cited by 258
Label-Free Plasmonic Biosensors for Point-of-Care Diagnostics: A Review
Soler, M., Huertas, C. S., & Lechuga, L. M. (2019) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2019.1554435 · Cited by 236
Metadata
- Authors
- Aćimović, S. S., Ortega, M. A., Sanz, V., Berthelot, J., Garcia-Cordero, J. L., Renger, J., Maerkl, S. J., Kreuzer, M. P., & Quidant, R.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-04-17
- Volume
- 14
- Issue
- 5
- Pages
- 2636-2641
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W1989685292
- Cited by
- 310
- References
- 28
- FWCI
- 18.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.