Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 322

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Multifunctional Stable and pH-Responsive Polymer Vesicles Formed by Heterofunctional Triblock Copolymer for Targeted Anticancer Drug Delivery and Ultrasensitive MR Imaging

Yang, Xiaoqiang, Grailer, Jamison J., Rowland, Ian J., Javadi, Alireza, Hurley, Samuel A., Matson, Vyara Z., Steeber, Douglas A., Gong, Shaoqin·2010·ACS Nano

Abstract

A multifunctional stable and pH-responsive polymer vesicle nanocarrier system was developed for combined tumor-targeted delivery of an anticancer drug and superparamagnetic iron oxide (SPIO) nanoparticles (NPs). These multifunctional polymer vesicles were formed by heterofunctional amphiphilic triblock copolymers, that is, R (folate (FA) or methoxy)-poly(ethylene glycol)(M(w):5000)-poly(glutamate hydrozone doxorubicin)-poly(ethylene glycol) (M(w):2000)-acrylate (i.e., R (FA or methoxy)-PEG(114)-P(Glu-Hyd-DOX)-PEG(46)-acrylate). The amphiphilic triblock copolymers can self-assemble into stable vesicles in aqueous solution. It was found that the long PEG segments were mostly segregated into the outer hydrophilic PEG layers of the vesicles, thereby providing active tumor targeting via FA, while the short PEG segments were mostly segregated into the inner hydrophilic PEG layer of the vesicles, thereby making it possible to cross-link the inner PEG layer via the acrylate groups for enhanced in vivo stability. The therapeutic drug, DOX, was conjugated onto the polyglutamate segment, which formed the hydrophobic membrane of the vesicles using a pH-sensitive hydrazone bond to achieve pH-responsive drug release, while the hydrophilic SPIO NPs were encapsulated into the aqueous core of the stable vesicles, allowing for ultrasensitive magnetic resonance imaging (MRI) detection. The SPIO/DOX-loaded vesicles demonstrated a much higher r(2) relaxivity value than Feridex, a commercially available SPIO-based T(2) contrast agent, which was attributed to the high SPIO NPs loading level and the SPIO clustering effect in the aqueous core of the vesicles. Results from flow cytometry and confocal laser scanning microscopy (CLSM) analysis showed that FA-conjugated vesicles exhibited higher cellular uptake than FA-free vesicles which also led to higher cytotoxicity. Thus, these tumor-targeting multifunctional SPIO/DOX-loaded vesicles will provide excellent in vivo stability, pH-controlled drug release, as well as enhanced MRI contrast, thereby making targeted cancer therapy and diagnosis possible.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nn101670k

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 322

Metadata

Authors
Yang, X., Grailer, J. J., Rowland, I. J., Javadi, A., Hurley, S. A., Matson, V. Z., Steeber, D. A., & Gong, S.
Venue
ACS Nano
Published
2010-10-19
Volume
4
Issue
11
Pages
6805-6817
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2316671269
Cited by
322
References
3
FWCI
10.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multifunctional Stable and pH-Responsive Polymer Vesicles Formed by Heterofunctional Triblock Copolymer for Targeted Anticancer Drug Delivery and Ultrasensitive MR Imaging. https://app.cochat.ai/papers/10.1021/nn101670k
The paper
Yang, X., Grailer, J. J., Rowland, I. J., Javadi, A., Hurley, S. A., Matson, V. Z., Steeber, D. A., & Gong, S. (2010). Multifunctional Stable and pH-Responsive Polymer Vesicles Formed by Heterofunctional Triblock Copolymer for Targeted Anticancer Drug Delivery and Ultrasensitive MR Imaging. ACS Nano. https://doi.org/10.1021/nn101670k

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.