Superior Electrochemical Performance of Carbon Nanotubes Directly Grown on Sharp Microelectrodes
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
We report for the first time how coatings made by directly growing carbon nanotubes (CNTs) on the tip of neural microelectrodes outperform others made by electrodeposited CNT composites. Not only do they reduce microelectrode impedance but they also are able to inject high currents without degradation and are stable in time. These results suggest that they are excellent candidates for chronic applications especially when both neural recording and stimulation have to be performed by the same microelectrode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · cited 2×
“To fully assess this possibility, we have estimated the charge injection limit for a set of typical electrodes, using cathodic-first charge-balanced biphasic symmetric current pulses, commonly used in electrophysiology experiments.(3,31,32) The charge injection limit is defined as the maximum quantity of charge an ele…”
BackgroundMethodElectrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · cited 1×
“To fully assess this possibility, we have estimated the charge injection limit for a set of typical electrodes, using cathodic-first charge-balanced biphasic symmetric current pulses, commonly used in electrophysiology experiments.(3,31,32) The charge injection limit is defined as the maximum quantity of charge an ele…”
MethodCarbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721 · cited 1×
“The other chosen benchmark, Au-CNT, has the interesting feature of being derived from standard metal plating techniques usually available in neurophysiology laboratories.(11,23) Starting from a 10 mM potassium dicyanaurate(I) (Sigma-Aldrich) aqueous solution containing 1.”
BackgroundCarbon Nanotube Substrates Boost Neuronal Electrical Signaling
Lovat, V., Pantarotto, D., Lagostena, L., Cacciari, B., Grandolfo, M., Righi, M., Spalluto, G., Prato, M., & Ballerini, L. (2005) · Nano Letters · doi:10.1021/nl050637m · Cited by 648
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
Cogan, S. F., Guzelian, A. A., Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.02.019 · Cited by 210
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Electrodeposited polypyrrole/carbon nanotubes composite films electrodes for neural interfaces
Lu, Y., Li, T., Zhao, X., Li, M., Cao, Y., Yang, H., & Duan, Y. Y. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.022 · Cited by 191 · cited 1×
“As it could be expected from the lower impedance, the highest Qinj (7 mC 3 cm ) was achieved using PPy-CNT coating, a value very close to the ones previously reported for similar electrodes.(25) In the case of Figure 3.”
Biocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160 · cited 1×
“transport and minimize inflammatory reaction and gliosis.(4) The vast majority of elec-”
BackgroundCui, X., & Martin, D. C. (2003) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(02)00427-2 · Cited by 160
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
Ultra-flexible fibrous supercapacitors with carbon nanotube/polypyrrole brush-like electrodes
Cherusseri, J., & Kar, K. K. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta02690g · Cited by 175
Vomero, M., Castagnola, E., Ciarpella, F., Maggiolini, E., Goshi, N., Zucchini, E., Carli, S., Fadiga, L., Kassegne, S., & Ricci, D. (2017) · Scientific Reports · doi:10.1038/srep40332 · Cited by 158
“…injection limit - defined as the maximum quantity of charge an electrode can inject before reaching the water electrolysis potential - previously calculated for metal microelectrodes 35 , and comparable to the one used to evoke sensations in human using millimeter-scale surface ECoG electrodes 47 .”
Self-citationNeural interfaces engineered via micro- and nanostructured coatings
Chen, N., Tian, L., Patil, A. C., Peng, S., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2017) · Nano Today · doi:10.1016/j.nantod.2017.04.007 · Cited by 74
Yin, P., Liu, Y., Xiao, L., & Zhang, C. (2021) · Polymers · doi:10.3390/polym13162834 · Cited by 42
Metadata
- Authors
- Ansaldo, A., Castagnola, E., Maggiolini, E., Fadiga, L., & Ricci, D.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-02-22
- Volume
- 5
- Issue
- 3
- Pages
- 2206-2214
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2037049057
- Cited by
- 74
- References
- 10
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.