The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Ag2S Quantum Dot: A Bright and Biocompatible Fluorescent Nanoprobe in the Second Near-Infrared Window
Open accessAbstract
Ag(2)S quantum dots (QDs) emitting in the second near-infrared region (NIR-II, 1.0-1.4 μm) are demonstrated as a promising fluorescent probe with both bright photoluminescence and high biocompatibility for the first time. Highly selective in vitro targeting and imaging of different cell lines are achieved using biocompatible NIR-II Ag(2)S QDs with different targeting ligands. The cytotoxicity study illustrates the Ag(2)S QDs with negligible effects in altering cell proliferation, triggering apoptosis and necrosis, generating reactive oxygen species, and causing DNA damage. Our results have opened up the possibilities of using these biocompatible Ag(2)S QDs for in vivo anatomical imaging and early stage tumor diagnosis with deep tissue penetration, high sensitivity, and elevated spatial and temporal resolution owing to their high emission efficiency in the unique NIR-II imaging window.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
A route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Self-citationWelsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Self-citation
Cited by
Multifunctional in vivo vascular imaging using near-infrared II fluorescence
Hong, G., Lee, J. C., Robinson, J. T., Raaz, U., Xie, L., Huang, N. F., Cooke, J. P., & Dai, H. (2012) · Nature Medicine · doi:10.1038/nm.2995 · Cited by 995
Self-citationIn Vivo Fluorescence Imaging with Ag2S Quantum Dots in the Second Near‐Infrared Region
Hong, G., Robinson, J. T., Zhang, Y., Diao, S., Antaris, A. L., Wang, Q., & Dai, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201206059 · Cited by 744
Self-citationHemmer, E., Benayas, A., Légaré, F., & Vetrone, F. (2016) · Nanoscale Horizons · doi:10.1039/c5nh00073d · Cited by 731
Next-generation in vivo optical imaging with short-wave infrared quantum dots
Bruns, O. T., Bischof, T. S., Harris, D. K., Franke, D., Shi, Y., Riedemann, L., Bartelt, A., Jaworski, F. B., Carr, J. A., Rowlands, C. J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0056 · Cited by 686
Li, B., Lu, L., Zhao, M., Lei, Z., & Zhang, F. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201801226 · Cited by 658
Metadata
- Authors
- Zhang, Y., Hong, G., Zhang, Y., Chen, G., Li, F., Dai, H., & Wang, Q.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-04-27
- Volume
- 6
- Issue
- 5
- Pages
- 3695-3702
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2315759364
- Cited by
- 765
- References
- 3
- FWCI
- 21.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.