The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Microfluidic Mixing and the Formation of Nanoscale Lipid Vesicles
Abstract
We investigate the formation of unilamellar lipid vesicles (liposomes) with diameters of tens of nanometers by controlled microfluidic mixing and nanoparticle determination (COMMAND). Our study includes liposome synthesis experiments and numerical modeling of our microfluidic implementation of the batch solvent injection method. We consider microfluidic liposome formation from the perspective of fluid interfaces and convective-diffusive mixing, as we find that bulk fluid flow parameters including hydrodynamically focused alcohol stream width, final alcohol concentration, and shear stress do not primarily determine the vesicle formation process. Microfluidic device geometry in conjunction with hydrodynamic flow focusing strongly influences vesicle size distributions, providing a coarse method to control liposome size, while total flow rate allows fine-tuning the vesicle size in certain focusing regimes. Although microfluidic liposome synthesis is relatively simple to implement experimentally, numerical simulations of the mixing process reveal a complex system of fluid flow and mass transfer determining the formation of nonequilibrium vesicles. These results expand our understanding of the microfluidic environment that controls liposome self-assembly and yield several technological advances for the on-chip synthesis of nanoscale lipid vesicles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion of univalent ions across the lamellae of swollen phospholipids
Bangham, A. D., Standish, M. M., & Watkins, J. C. (1965) · Journal of Molecular Biology · doi:10.1016/s0022-2836(65)80093-6 · Cited by 4,664
The Scattering of Light and Other Electromagnetic Radiation
(1969) · Elsevier eBooks · doi:10.1016/c2013-0-06195-6 · Cited by 3,816
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Vesicles of variable sizes produced by a rapid extrusion procedure
Mayer, L. D., Hope, M. J., & Cullis, P. R. (1986) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(86)90302-0 · Cited by 1,691
Small-volume extrusion apparatus for preparation of large, unilamellar vesicles
MacDonald, R. C., MacDonald, R. I., Menco, B. P. M., Takeshita, K., Subbarao, N. K., & Hu, L.-R. (1991) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(91)90295-j · Cited by 1,493
Vesicles and Liposomes: A Self‐Assembly Principle Beyond Lipids
Antonietti, M., & Förster, S. (2003) · Advanced Materials · doi:10.1002/adma.200300010 · Cited by 1,403
Single bilayer liposomes prepared without sonication
Batzri, S., & Korn, E. D. (1973) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(73)90408-2 · Cited by 1,358
Molecular segregation observed in a concentrated alcohol–water solution
Dixit, S., Crain, J., Poon, W. C. K., Finney, J. L., & Soper, A. K. (2002) · Nature · doi:10.1038/416829a · Cited by 967
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Microfluidic Platform for Controlled Synthesis of Polymeric Nanoparticles
Karnik, R., Gu, F., Basto, P., Cannizzaro, C., Dean, L., Kyei-Manu, W., Langer, R., & Farokhzad, O. C. (2008) · Nano Letters · doi:10.1021/nl801736q · Cited by 887
Cited by
New developments in liposomal drug delivery
Pattni, B. S., Chupin, V. V., & Torchilin, V. P. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00046 · Cited by 1,600
Advanced materials and processing for drug delivery: The past and the future
Zhang, Y., Chan, H. F., & Leong, K. W. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.10.003 · Cited by 1,000
Liposomes: Advancements and innovation in the manufacturing process
Shah, S., Dhawan, V., Holm, R., Nagarsenker, M. S., & Perrie, Y. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.07.002 · Cited by 745
Microfluidic Synthesis of Highly Potent Limit-size Lipid Nanoparticles for In Vivo Delivery of siRNA
Belliveau, N. M., Huft, J., Lin, P. J., Chen, S., Leung, A. K., Leaver, T. J., Wild, A. W., Lee, J. B., Taylor, R. J., Tam, Y. K., et al. (2012) · Molecular Therapy - Nucleic Acids · doi:10.1038/mtna.2012.28 · Cited by 685
Novel methods for liposome preparation
Patil, Y. P., & Jadhav, S. (2014) · Chemistry and Physics of Lipids · doi:10.1016/j.chemphyslip.2013.10.011 · Cited by 638
Recent advancements in liposome technology
Filipczak, N., Pan, J., Yalamarty, S. S. K., & Torchilin, V. P. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.06.022 · Cited by 592
Kim, J., Eygeris, Y., Gupta, M., & Sahay, G. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.12.014 · Cited by 514
Liposome production by microfluidics: potential and limiting factors
Carugo, D., Bottaro, E., Owen, J., Stride, E., & Nastruzzi, C. (2016) · Scientific Reports · doi:10.1038/srep25876 · Cited by 440
Microfluidic formulation of nanoparticles for biomedical applications
Shepherd, S. J., Issadore, D., & Mitchell, M. J. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120826 · Cited by 433
Chen, D., Love, K. T., Chen, Y., Eltoukhy, A. A., Kastrup, C., Sahay, G., Jeon, A., Dong, Y., Whitehead, K. A., & Anderson, D. G. (2012) · Journal of the American Chemical Society · doi:10.1021/ja301621z · Cited by 424
Soft fluorescent nanomaterials for biological and biomedical imaging
Peng, H.-S., & Chiu, D. T. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00294f · Cited by 407
Microfluidic methods for forming liposomes
van Swaay, D., & deMello, A. (2013) · Lab on a Chip · doi:10.1039/c2lc41121k · Cited by 379
A comprehensive review on recent preparation techniques of liposomes
Has, C., & Sunthar, P. (2020) · Journal of Liposome Research · doi:10.1080/08982104.2019.1668010 · Cited by 357
Microfluidic technologies and devices for lipid nanoparticle-based RNA delivery
Maeki, M., Uno, S., Niwa, A., Okada, Y., & Tokeshi, M. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.02.017 · Cited by 349
Zhigaltsev, I. V., Belliveau, N., Hafez, I., Leung, A. K. K., Huft, J., Hansen, C., & Cullis, P. R. (2012) · Langmuir · doi:10.1021/la204833h · Cited by 345
Evers, M. J. W., Kulkarni, J. A., van der Meel, R., Cullis, P. R., Vader, P., & Schiffelers, R. M. (2018) · Small Methods · doi:10.1002/smtd.201700375 · Cited by 332
Manufacturing Considerations for the Development of Lipid Nanoparticles Using Microfluidics
Roces, C. B., Lou, G., Jain, N., Abraham, S., Thomas, A., Halbert, G. W., & Perrie, Y. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12111095 · Cited by 321
Maeki, M., Kimura, N., Sato, Y., Harashima, H., & Tokeshi, M. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.03.008 · Cited by 319
Scalable mRNA and siRNA Lipid Nanoparticle Production Using a Parallelized Microfluidic Device
Shepherd, S. J., Warzecha, C. C., Yadavali, S., El-Mayta, R., Alameh, M.-G., Wang, L., Weissman, D., Wilson, J. M., Issadore, D., & Mitchell, M. J. (2021) · Nano Letters · doi:10.1021/acs.nanolett.1c01353 · Cited by 317
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Polymer-guided assembly of inorganic nanoparticles
Yi, C., Yang, Y., Liu, B., He, J., & Nie, Z. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00725c · Cited by 305
Lim, J.-M., Swami, A., Gilson, L. M., Chopra, S., Choi, S., Wu, J., Langer, R., Karnik, R., & Farokhzad, O. C. (2014) · ACS Nano · doi:10.1021/nn501371n · Cited by 297
Microfluidic Nanoparticles for Drug Delivery
Liu, Y., Yang, G., Hui, Y., Ranaweera, S., & Zhao, C. (2022) · Small · doi:10.1002/smll.202106580 · Cited by 277
Metadata
- Authors
- Jahn, A., Stavis, S. M., Hong, J. S., Vreeland, W. N., DeVoe, D. L., & Gaitan, M.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-03-31
- Volume
- 4
- Issue
- 4
- Pages
- 2077-2087
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2120764900
- Cited by
- 432
- References
- 40
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.