Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The present experimental study was designed to address two issues. The first was to investigate whether oxide properties of titanium implants influenced bone tissue responses after an in vivo implantation time of six weeks. If such a result was found, the second aim was to investigate which oxide properties are involved in such bone tissue responses. Screw‐shaped implants with a wide range of oxide properties were prepared by electrochemical oxidation methods, where the oxide thickness varied in the range of 200 nm to 1000 nm. The surface morphology was prepared in two substantially different ways, i.e. barrier and porous oxide film structures. The micropore structure revealed pore sizes of 8 μm in diameter, with a range in opening area from 1.27 μm 2 to 2.1 μm 2. Porosity ranged from 12.7% to 24.4%. The crystal structures of the titanium oxide were amorphous, anatase and a mixture of anatase and rutile type. The chemical compositions consisted mainly of TiO 2. Surface roughness ranged from 0.96 μm to 1.03 μm (Sa). Each group of test samples showed its own, defined status with respect to these various parameters. The oxide properties of turned commercially pure titanium implants were used in the control group, which was characterized by an oxide thickness of 17.4 ± 6.2 nm, amorphous type in crystallinity, TiO 2 in chemical composition, and a surface roughness of 0.83 μm (Sa). Bone tissue responses were evaluated by resonance frequency measurements and removal torque tests that were undertaken six weeks after implant insertion in rabbit tibia. Implants that had an oxide thickness of approximately 600, 800 and 1000 nm demonstrated significantly stronger bone responses in the evaluation of removal torque values than did implants that had an oxide thickness of approximately 17 and 200 nm (P < 0.05). However, there were no difference between implants with oxide thicknesses of 17 and 200 nm (P = 0.99). It was concluded that oxide properties of titanium implants, which include oxide thickness, micropore configurations and crystal structures, greatly influence the bone tissue response in the evaluation of removal torque values. However, it is not fully understood whether these oxide properties influence the bone tissue response separately or synergistically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Baltosser, W. H., & Zar, J. H. (1996) · Ecology · doi:10.2307/2265725 · Cited by 35,166
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678108991776 · Cited by 2,690
Self-citationThe electrochemical oxide growth behaviour on titanium in acid and alkaline electrolytes
Sul, Y., Johansson, C. B., Jeong, Y., & Albrektsson, T. O. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00050-9 · Cited by 624
Self-citationEffect of surface topology on the osseointegration of implant materials in trabecular bone
Wong, M., Eulenberger, J., Schenk, R., & Hunziker, E. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291213 · Cited by 449
The interface zone of inorganic implantsIn vivo: Titanium implants in bone
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., Kasemo, B., Larsson, K., Lundström, I., McQueen, D. H., & Skalak, R. (1983) · Annals of Biomedical Engineering · doi:10.1007/bf02363944 · Cited by 436
Self-citationWennerberg, A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)80750-2 · Cited by 355
Self-citationRemoval torques for polished and rough titanium implants.
Carlsson, L. V., Röstlund, T., Albrektsson, B., & Albrektsson, T. O. (1988) · PubMed · Cited by 298
Self-citationQualitative and quantitative observations of bone tissue reactions to anodised implants
Sul, Y.-T., Johansson, C. B., Röser, K., & Albrektsson, T. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00307-6 · Cited by 196
Self-citationLarsson, C., Emanuelsson, L., Thomsen, P., Ericson, L. E., Aronsson, B. ‐., Kasemo, B., & Lausmaa, J. (1997) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1018548225899 · Cited by 66
On the bone tissue response to titanium implants
Sennerby, L. (1991) · Gothenburg University Publications Electronic Archive (Gothenburg University) · Cited by 46
Cited by
Porosity of 3D biomaterial scaffolds and osteogenesis
Karageorgiou, V., & Kaplan, D. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.002 · Cited by 6,622
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Effects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
Self-citationBiomaterial strategies for engineering implants for enhanced osseointegration and bone repair
Agarwal, R., & García, A. J. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.013 · Cited by 789
Bosshardt, D. D., Chappuis, V., & Buser, D. (2017) · Periodontology 2000 · doi:10.1111/prd.12179 · Cited by 574
Effects of implant surface coatings and composition on bone integration: a systematic review
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01777.x · Cited by 535
Effects of topography and composition of titanium surface oxides on osteoblast responses
Zhu, X., Chen, J., Scheideler, L., Reichl, R., & Geis-Gerstorfer, J. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.11.011 · Cited by 534
Javed, F., Ahmed, H. B., Crespi, R., & Romanos, G. E. (2013) · Interventional Medicine and Applied Science · doi:10.1556/imas.5.2013.4.3 · Cited by 457
Sul, Y. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00261-8 · Cited by 388
Self-citationBasic research methods and current trends of dental implant surfaces
Coelho, P. G., Granjeiro, J. M., Romanos, G. E., Suzuki, M., Silva, N. R. F., Cardaropoli, G., Thompson, V. P., & Lemons, J. E. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31264 · Cited by 359
Oshida, Y., Tuna, E. B., Aktören, O., & Gençay, K. (2010) · International Journal of Molecular Sciences · doi:10.3390/ijms11041580 · Cited by 216
Improving osseointegration of dental implants
Elias, C. N., & Meirelles, L. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.09.74 · Cited by 188
Toward the biomimetic implant surface: Biopolymers on titanium-based implants for bone regeneration
Tejero, R., Anitua, E., & Orive, G. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.01.001 · Cited by 187
Metadata
- Authors
- Sul, Y., Johansson, C. B., Jeong, Y., Wennerberg, A., & Albrektsson, T.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2002-05-12
- Volume
- 13
- Issue
- 3
- Pages
- 252-259
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2068040174
- Cited by
- 214
- References
- 10
- FWCI
- 11.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.