Ozone in Indoor Environments: Concentration and Chemistry
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
The concentration of indoor ozone depends on a number of factors, including the outdoor ozone concentration, air exchange rates, indoor emission rates, surface removal rates, and reactions between ozone and other chemicals in the air. Outdoor ozone concentrations often display strong diurnal variations, and this adds a dynamic excitation to the transport and chemical mechanisms at play. Hence, indoor ozone concentrations can vary significantly from hour-to-hour, day-to-day, and season-to-season, as well as from room-to-room and structure-to-structure. Under normal conditions, the half-life of ozone indoors is between 7 and 10 min and is determined primarily by surface removal and air exchange. Although reactions between ozone and most other indoor pollutants are thermodynamically favorable, in the majority of cases they are quite slow. Rate constants for reactions of ozone with the more commonly identified indoor pollutants are summarized in this article. They show that only a small fraction of the reactions occur at a rate fast enough to compete with air exchange, assuming typical indoor ozone concentrations. In the case of organic compounds, the "fast" reactions involve compounds with unsaturated carbon-carbon bonds. Although such compounds typically comprise less than 10% of indoor pollutants, their reactions with ozone have the potential to be quite significant as sources of indoor free radicals and multifunctional (-C=O, -COOH, -OH) stable compounds that are often quite odorous. The stable compounds are present as both gas phase and condensed phase species, with the latter contributing to the overall concentration of indoor submicron particles. Indeed, ozone/alkene reactions provide a link between outdoor ozone, outdoor particles and indoor particles. Indoor ozone and the products derived from reactions initiated by indoor ozone are potentially damaging to both human health and materials; more detailed explication of these impacts is an area of active investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1999) · Choice Reviews Online · doi:10.5860/choice.37-0940 · Cited by 14,314
ASHRAE Handbook—1981 Fundamentals
(1981) · Building Services Engineering Research and Technology · doi:10.1177/014362448100200409 · Cited by 3,403
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
Atkinson, R., Baulch, D. L., Cox, R. A., Hampson, R. F., Kerr, J. A., & Troe, J. (1992) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555918 · Cited by 1,289
Tropospheric ozone: Seasonal behavior, trends, and anthropogenic influence
Logan, J. A. (1985) · Journal of Geophysical Research: Atmospheres · doi:10.1029/jd090id06p10463 · Cited by 1,060
Finlayson-Pitts, B. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003038107 · Cited by 996
Stratospheric-Tropospheric Exchange Based on Radioactivity, Ozone and Potential Vorticity
Danielsen, E. F. (1968) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1968)025<0502:stebor>2.0.co;2 · Cited by 887
What controls tropospheric ozone?
Lelieveld, J., & Dentener, F. J. (2000) · Journal of Geophysical Research: Atmospheres · doi:10.1029/1999jd901011 · Cited by 731
Rethinking the ozone problem in urban and regional air pollution
(1993) · Environment International · doi:10.1016/0160-4120(93)90017-c · Cited by 694
Concentrations of Volatile Organic Compounds in Indoor Air - A Review
Brown, S. K., Sim, M. R., Abramson, M. J., & Gray, C. N. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00007.x · Cited by 559
Carboxylic Acids in Secondary Aerosols from Oxidation of Cyclic Monoterpenes by Ozone
Glasius, M., Lahaniati, M., Calogirou, A., Di Bella, D., Jensen, N. R., Hjorth, J., Kotzias, D., & Larsen, B. R. (2000) · Environmental Science & Technology · doi:10.1021/es990445r · Cited by 325
Indoor ozone/terpene reactions as a source of indoor particles
Weschler, C. J., & Shields, H. C. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00083-7 · Cited by 319
Self-citationMathematical modeling of chemically reactive pollutants in indoor air
Nazaroff, W. W., & Cass, G. R. (1986) · Environmental Science & Technology · doi:10.1021/es00151a012 · Cited by 296
Ozone and limonene in indoor air: a source of submicron particle exposure.
Wainman, T., Zhang, J., Weschler, C. J., & Lioy, P. J. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.001081139 · Cited by 274
Self-citationIdentification of Products Containing −COOH, −OH, and −CO in Atmospheric Oxidation of Hydrocarbons
Yu, J., Flagan, R. C., & Seinfeld, J. H. (1998) · Environmental Science & Technology · doi:10.1021/es980129x · Cited by 268
NIST Chemical Kinetics Database
Mallard, W. G., Westley, F., Herron, J. T., Hampson, R. F., & Frizzell, D. H. (1998) · Cited by 260
Potential reactions among indoor pollutants
Weschler, C. J., & Shields, H. C. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(97)00219-7 · Cited by 257
Self-citationFormation of Strong Airway Irritants in Terpene/Ozone Mixtures
WOLKOFF, P., CLAUSEN, P. A., WILKINS, C. K., & NIELSEN, G. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010002082.x · Cited by 253
Murray, D. M., & Burmaster, D. E. (1995) · Risk Analysis · doi:10.1111/j.1539-6924.1995.tb00338.x · Cited by 250
Air oxidation of d‐limonene (the citrus solvent) creates potent allergens
Karlberg, A., Magnusson, K., & Nilsson, U. (1992) · Contact Dermatitis · doi:10.1111/j.1600-0536.1992.tb00129.x · Cited by 243
Indoor chemistry: ozone, volatile organic compounds, and carpets
Weschler, C. J., Hodgson, A. T., & Wooley, J. D. (1992) · Environmental Science & Technology · doi:10.1021/es00036a006 · Cited by 233
Self-citationAtmospheric Change: An Earth System Perspective
Graedel, T. E., & Crutzen, P. J. (1992) · Medical Entomology and Zoology · Cited by 214
Zhang, J., Lioy, P. J., & He, Q. (1994) · Environmental Science & Technology · doi:10.1021/es00050a020 · Cited by 210
Production of the Hydroxyl Radical in Indoor Air
Weschler, C. J., & Shields, H. C. (1996) · Environmental Science & Technology · doi:10.1021/es960032f · Cited by 208
Self-citationThe composition of museum atmospheres
Brimblecombe, P. (1990) · Atmospheric Environment Part B Urban Atmosphere · doi:10.1016/0957-1272(90)90003-d · Cited by 176
Grosjean, D., Williams, E. L., Grosjean, E., Andino, J. M., & Seinfeld, J. H. (1993) · Environmental Science & Technology · doi:10.1021/es00049a014 · Cited by 167
Weschler, C. J., Shields, H. C., & Naik, D. V. (1994) · Environmental Science & Technology · doi:10.1021/es00061a021 · Cited by 158
Self-citationDaisey, J. M., Hodgson, A. T., Fisk, W. J., Mendell, M. J., & Brinke, J. T. (1994) · Atmospheric Environment · doi:10.1016/1352-2310(94)00200-5 · Cited by 153
WESCHLER, C. J., & SHIELDS, H. C. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010002092.x · Cited by 150
Self-citationAtmospheric oxidation of selected terpenes and related carbonyls: gas-phase carbonyl products
Grosjean, D., Williams, E. L., & Seinfeld, J. H. (1992) · Environmental Science & Technology · doi:10.1021/es00032a005 · Cited by 143
Measurements of the Hydroxyl Radical in a Manipulated but Realistic Indoor Environment
Weschler, C. J., & Shields, H. C. (1997) · Environmental Science & Technology · doi:10.1021/es970669e · Cited by 126
Self-citationProducts of the Gas-Phase Reactions of O3 with Alkenes
Atkinson, R., Tuazon, E. C., & Aschmann, S. M. (1995) · Environmental Science & Technology · doi:10.1021/es00007a025 · Cited by 110
Shields, H. C., Fleischer, D. M., & Weschler, C. J. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.t01-3-00002.x · Cited by 110
Self-citationUse of Ozone Generating Devices to Improve Indoor Air Quality
Boeniger, M. F. (1995) · American Industrial Hygiene Association Journal · doi:10.1080/15428119591016827 · Cited by 104
Formation of strong airway irritants in a model mixture of (+)-α-pinene/ozone
Wolkoff, P. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(98)00292-1 · Cited by 102
Weschler, C. J., Brauer, M., & Koutrakis, P. (1992) · Environmental Science & Technology · doi:10.1021/es00025a022 · Cited by 100
Self-citationOzone Reactive Chemistry on Interior Latex Paint
Reiss, R., Ryan, P. B., Koutrakis, P., & Tibbetts, S. J. (1995) · Environmental Science & Technology · doi:10.1021/es00008a007 · Cited by 100
Ozone Decay Rates in Residences
Lee, K., Vallarino, J., Dumyahn, T. S., Özkaynak, H., & Spengler, J. D. (1999) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1999.10463913 · Cited by 95
Reiss, R., Ryan, P. B., Tibbetts, S. J., & Koutrakis, P. (1995) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1995.10467411 · Cited by 95
Ozone personal exposures and health effects for selected groups residing in the Fraser Valley
Brauer, M. D., & Brook, J. R. (1997) · Atmospheric Environment · doi:10.1016/s1352-2310(96)00129-x · Cited by 89
Use of an Indoor Air Quality Model (IAQM) to Estimate Indoor Ozone Levels
Hayes, S. R. (1991) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1991.10466833 · Cited by 84
Ozone in Residential Air: Concentrations, I/O Ratios, Indoor Chemistry, and Exposures
Zhang, J., & Lioy, P. J. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00004.x · Cited by 81
Measurement of Indoor Air Emissions from Dry-Process Photocopy Machines
Leovic, K. W., Sheldon, L. S., Whitaker, D. A., Hetes, R. G., Calcagni, J., & Baskir, J. N. (1996) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1996.10467517 · Cited by 77
Assessment of Ozone Exposures in the Greater Metropolitan Toronto Area
Liu, L. J., Koutrakis, P., Leech, J. A., & Broder, I. (1995) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1995.10467362 · Cited by 70
Modeling Ozone Levels in and around Southern California Homes
Avol, E. L., Navidi, W. C., & Colome, S. D. (1998) · Environmental Science & Technology · doi:10.1021/es970351m · Cited by 61
Evaluation of Indoor Ozone Concentration and Predictors of Indoor-Outdoor Ratio in Mexico City
Romieu, I., Lugo, M. C., Colome, S., García, A. M., Hernández‐Ávila, M., Geyh, A., Ruiz‐Velasco, S., & Rendón, E. P. (1998) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1998.10463684 · Cited by 37
Lawrence Berkeley National Lab. (LBNL), B., Morrison, G., & USDOE Office of Energy Efficiency and Renewable Energy (EERE) (1999) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/753890 · Cited by 12
Cited by
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Metal oxide nanoparticles and their applications in nanotechnology
Chavali, M. S., & Nikolova, M. P. (2019) · SN Applied Sciences · doi:10.1007/s42452-019-0592-3 · Cited by 1,133
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Cleaning products and air fresheners: exposure to primary and secondary air pollutants
Nazaroff, W. W., & Weschler, C. J. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.02.040 · Cited by 846
Self-citationTran, V. V., Park, D., & Lee, Y.-C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17082927 · Cited by 822
Metadata
- Authors
- WESCHLER, C. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2000-12
- Volume
- 10
- Issue
- 4
- Pages
- 269-288
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2078807751
- Cited by
- 758
- References
- 47
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.