Ozone in Indoor Environments: Concentration and Chemistry
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
The concentration of indoor ozone depends on a number of factors, including the outdoor ozone concentration, air exchange rates, indoor emission rates, surface removal rates, and reactions between ozone and other chemicals in the air. Outdoor ozone concentrations often display strong diurnal variations, and this adds a dynamic excitation to the transport and chemical mechanisms at play. Hence, indoor ozone concentrations can vary significantly from hour-to-hour, day-to-day, and season-to-season, as well as from room-to-room and structure-to-structure. Under normal conditions, the half-life of ozone indoors is between 7 and 10 min and is determined primarily by surface removal and air exchange. Although reactions between ozone and most other indoor pollutants are thermodynamically favorable, in the majority of cases they are quite slow. Rate constants for reactions of ozone with the more commonly identified indoor pollutants are summarized in this article. They show that only a small fraction of the reactions occur at a rate fast enough to compete with air exchange, assuming typical indoor ozone concentrations. In the case of organic compounds, the "fast" reactions involve compounds with unsaturated carbon-carbon bonds. Although such compounds typically comprise less than 10% of indoor pollutants, their reactions with ozone have the potential to be quite significant as sources of indoor free radicals and multifunctional (-C=O, -COOH, -OH) stable compounds that are often quite odorous. The stable compounds are present as both gas phase and condensed phase species, with the latter contributing to the overall concentration of indoor submicron particles. Indeed, ozone/alkene reactions provide a link between outdoor ozone, outdoor particles and indoor particles. Indoor ozone and the products derived from reactions initiated by indoor ozone are potentially damaging to both human health and materials; more detailed explication of these impacts is an area of active investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1999) · Choice Reviews Online · doi:10.5860/choice.37-0940 · Cited by 14,314
ASHRAE Handbook—1981 Fundamentals
(1981) · Building Services Engineering Research and Technology · doi:10.1177/014362448100200409 · Cited by 3,403
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
Atkinson, R., Baulch, D. L., Cox, R. A., Hampson, R. F., Kerr, J. A., & Troe, J. (1992) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555918 · Cited by 1,289
Tropospheric ozone: Seasonal behavior, trends, and anthropogenic influence
Logan, J. A. (1985) · Journal of Geophysical Research: Atmospheres · doi:10.1029/jd090id06p10463 · Cited by 1,060
Finlayson-Pitts, B. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003038107 · Cited by 996
Stratospheric-Tropospheric Exchange Based on Radioactivity, Ozone and Potential Vorticity
Danielsen, E. F. (1968) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1968)025<0502:stebor>2.0.co;2 · Cited by 887
What controls tropospheric ozone?
Lelieveld, J., & Dentener, F. J. (2000) · Journal of Geophysical Research: Atmospheres · doi:10.1029/1999jd901011 · Cited by 731
Rethinking the ozone problem in urban and regional air pollution
(1993) · Environment International · doi:10.1016/0160-4120(93)90017-c · Cited by 694
Concentrations of Volatile Organic Compounds in Indoor Air - A Review
Brown, S. K., Sim, M. R., Abramson, M. J., & Gray, C. N. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00007.x · Cited by 559
Cited by
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Metal oxide nanoparticles and their applications in nanotechnology
Chavali, M. S., & Nikolova, M. P. (2019) · SN Applied Sciences · doi:10.1007/s42452-019-0592-3 · Cited by 1,133
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Cleaning products and air fresheners: exposure to primary and secondary air pollutants
Nazaroff, W. W., & Weschler, C. J. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.02.040 · Cited by 846
Self-citationTran, V. V., Park, D., & Lee, Y.-C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17082927 · Cited by 822
Al horr, Y., Arif, M., Katafygiotou, M., Mazroei, A., Kaushik, A., & Elsarrag, E. (2016) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2016.03.006 · Cited by 817
Changes in indoor pollutants since the 1950s
Weschler, C. J. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.044 · Cited by 669
Self-citationAir Pollution and Children’s Health
Schwartz, J. (2004) · Pediatrics · doi:10.1542/peds.113.s3.1037 · Cited by 658
On the history of indoor air quality and health
Sundell, J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00273.x · Cited by 613
Microbial Volatile Organic Compounds
Korpi, A., Järnberg, J., & Pasanen, A.-L. (2009) · Critical Reviews in Toxicology · doi:10.1080/10408440802291497 · Cited by 596
Weschler, C. J. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9256 · Cited by 481
Self-citationThirdhand Tobacco Smoke: Emerging Evidence and Arguments for a Multidisciplinary Research Agenda
Matt, G. E., Quintana, P. J. E., Destaillats, H., Gundel, L. A., Sleiman, M., Singer, B. C., Jacob, P., Benowitz, N., Winickoff, J. P., Rehan, V., et al. (2011) · Environmental Health Perspectives · doi:10.1289/ehp.1103500 · Cited by 453
Wisthaler, A., & Weschler, C. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904498106 · Cited by 444
Self-citationTham, K. W. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.071 · Cited by 399
Indoor air pollution: a global health concern
Zhang, J. (., & Smith, K. R. (2003) · British Medical Bulletin · doi:10.1093/bmb/ldg029 · Cited by 397
Organic compounds in indoor air—their relevance for perceived indoor air quality?
Wolkoff, P., & Nielsen, G. D. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00244-8 · Cited by 369
A review of indoor air treatment technologies
Luengas, A., Barona, A., Hort, C., Gallastegui, G., Platel, V., & Elias, A. (2015) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-015-9363-9 · Cited by 360
Wolkoff, P., Wilkins, C. K., Clausen, P. A., & Nielsen, G. D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00393.x · Cited by 348
Uhde, E., & Salthammer, T. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.05.082 · Cited by 347
Indoor air pollutants in office environments: Assessment of comfort, health, and performance
Wolkoff, P. (2013) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2012.08.001 · Cited by 342
Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone
Singer, B. C., Coleman, B. K., Destaillats, H., Hodgson, A. T., Lunden, M. M., Weschler, C. J., & Nazaroff, W. W. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.06.005 · Cited by 330
Self-citationRelationship between outdoor and indoor air quality in eight French schools
Blondeau, P., Iordache, V., Poupard, O., Genin, D., & Allard, F. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00263.x · Cited by 317
A review on prospects of essential oils as biopesticide in insect-pest management
Tripathi, A. K., Upadhyay, S., Bhuiyan, M., & Bhattacharya, P. (2009) · Journal of Pharmacognosy and Phytotherapy · doi:10.5897/jpp.9000003 · Cited by 309
Destaillats, H., Lunden, M. M., Singer, B. C., Coleman, B. K., Hodgson, A. T., Weschler, C. J., & Nazaroff, W. W. (2006) · Environmental Science & Technology · doi:10.1021/es052198z · Cited by 284
Self-citationThirdhand Smoke: New Evidence, Challenges, and Future Directions
Jacob, P., Benowitz, N. L., Destaillats, H., Gundel, L., Hang, B., Martins-Green, M., Matt, G. E., Quintana, P. J. E., Samet, J. M., Schick, S. F., et al. (2017) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.6b00343 · Cited by 273
Association of ozone exposure with cardiorespiratory pathophysiologic mechanisms in healthy adults
Day, D. B., Xiang, J., Mo, J., Li, F., Chung, M., Gong, J., Weschler, C. J., Ohman-Strickland, P. A., Sundell, J., Weng, W., et al. (2017) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2017.2842 · Cited by 264
The dichotomy of relative humidity on indoor air quality
Wolkoff, P., & Kjærgaard, S. K. (2007) · Environment International · doi:10.1016/j.envint.2007.04.004 · Cited by 260
Volatile Organic Compounds: Do they present a risk to our health?
Rumchev, K., Brown, H., & Spickett, J. (2007) · Reviews on Environmental Health · doi:10.1515/reveh.2007.22.1.39 · Cited by 249
Overview of HOMEChem: House Observations of Microbial and Environmental Chemistry
Farmer, D. K., Vance, M. E., Abbatt, J. P. D., Abeleira, A., Alves, M. R., Arata, C., Boedicker, E., Bourne, S., Cardoso-Saldaña, F., Corsi, R., et al. (2019) · Environmental Science: Processes & Impacts · doi:10.1039/c9em00228f · Cited by 220
Ultrafine particle removal and generation by portable air cleaners
Waring, M. S., Siegel, J. A., & Corsi, R. L. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.02.011 · Cited by 217
“…due to the device, C* (ppb), as C ¼ E=V lþ bO3 (2) where the air exchange rate, l, was again assumed as 0.5 h 1 (Murray and Burmaster, 1995), and the ozone deposition loss rate, bO3, was assumed as 4.0 h 1, which is an experimentally determined value for offices and bedrooms (Weschler, 2000).”
BackgroundInfluentialWhat can individuals do to reduce personal health risks from air pollution?
Laumbach, R. J., Meng, Q., & Kipen, H. M. (2015) · PubMed · doi:10.3978/j.issn.2072-1439.2014.12.21 · Cited by 212
Catalytic ozone decomposition and adsorptive VOCs removal in bimetallic metal-organic frameworks
Dong, C., Yang, J.-J., Xie, L.-H., Cui, G., Fang, W.-H., & Li, J.-R. (2022) · Nature Communications · doi:10.1038/s41467-022-32678-2 · Cited by 206
Roles of the human occupant in indoor chemistry
Weschler, C. J. (2016) · Indoor Air · doi:10.1111/ina.12185 · Cited by 200
“Earlier papers (e.g., Weschler et al., 1989; Weschler, 2000) have stated that, under steady-state conditions, the ratio of the indoor to the outdoor concentration for ozone (I/O) can be estimated by a simple expression:”
BackgroundSelf-citationThe atmospheric chemistry of indoor environments
Abbatt, J. P. D., & Wang, C. (2020) · Environmental Science: Processes & Impacts · doi:10.1039/c9em00386j · Cited by 200
Ye, W., Zhang, X., Gao, J., Cao, G., Zhou, X., & Su, X. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.02.047 · Cited by 198
“In residential context, although there are indoor sources of O3, indoor O3 has been primarily transported from outdoors (Weschler, 2000).”
Coleman, B. K., Destaillats, H., Hodgson, A. T., & Nazaroff, W. W. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.10.001 · Cited by 195
“summarized by Weschler, 2000 ), and ozone deposition to common residential and commercial”
BackgroundGong, S., Xie, Z., Li, W., Wu, X., Han, N., & Chen, Y. (2019) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2018.09.041 · Cited by 191
Growth of organic films on indoor surfaces
Weschler, C. J., & Nazaroff, W. W. (2017) · Indoor Air · doi:10.1111/ina.12396 · Cited by 188
Self-citationBell, M. L., & Dominici, F. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm396 · Cited by 183
“Given the highly reactive nature of ozone, indoor concentrations can be much lower than ambient levels, and ventilation characteristics can appreciably affect indoor/outdoor ratios of ozone levels (13, 14).”
BackgroundBako-Biro, Z., Wargocki, P., Weschler, C. J., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00218.x · Cited by 180
Self-citationde Gennaro, G., Dambruoso, P. R., Loiotile, A. D., Di Gilio, A., Giungato, P., Tutino, M., Marzocca, A., Mazzone, A., Palmisani, J., & Porcelli, F. (2014) · Environmental Chemistry Letters · doi:10.1007/s10311-014-0470-6 · Cited by 178
Waring, M. S., & Wells, J. R. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.06.062 · Cited by 168
“The initiator and main driver of indoor chemistry is O 3 , which is largely the result of outdoor-to-indoor transport, and indoor O 3 concentrations are often 20–70% of ambient values (Weschler, 2000).”
InfluentialHydroxyl radicals in indoor environments
Sarwar, G., Corsi, R., Kimura, Y., Allen, D., & Weschler, C. J. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00278-9 · Cited by 167
Self-citationResidential air‐change rates: A critical review
Nazaroff, W. W. (2021) · Indoor Air · doi:10.1111/ina.12785 · Cited by 161
LIU, W., ZHANG, J., ZHANG, L., TURPIN, B., WEISEL, C., MORANDI, M., STOCK, T., COLOME, S., & KORN, L. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.12.005 · Cited by 160
An Iron‐Containing Metal–Organic Framework as a Highly Efficient Catalyst for Ozone Decomposition
Wang, H., Rassu, P., Wang, X., Li, H., Wang, X., Wang, X., Feng, X., Yin, A., Li, P., Jin, X., et al. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201810268 · Cited by 160
Sources of indoor air pollution in New York City residences of asthmatic children
Habre, R., Coull, B., Moshier, E., Godbold, J., Grunin, A., Nath, A., Castro, W., Schachter, N., Rohr, A., Kattan, M., et al. (2014) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2013.74 · Cited by 158
The transformation of outdoor ammonium nitrate aerosols in the indoor environment
Lunden, M. M., Revzan, K. L., Fischer, M. L., Thatcher, T. L., Littlejohn, D., Hering, S. V., & Brown, N. J. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.035 · Cited by 152
“Many investigators have examined the indoor concentrations of particulate mass and gaseous species, including their transport into and out of buildings, emissions and formation indoors, and interactions between pollutants and the building surfaces and air handling equipment (Wallace, 1996; Weschler, 2000 ).”
BackgroundCummings, B. E., & Waring, M. S. (2020) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-019-0175-9 · Cited by 98
Mullen, N. A., Bhangar, S., Hering, S. V., Kreisberg, N. M., & Nazaroff, W. W. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00690.x · Cited by 90
Kumar, A., Singh, B. P., Punia, M., Singh, D., Kumar, K., & Jain, V. K. (2014) · Indoor Air · doi:10.1111/ina.12096 · Cited by 61
Acute effect of ambient ozone on heart rate variability in healthy elderly subjects
Jia, X., Song, X., Shima, M., Tamura, K., Deng, F., & Guo, X. (2011) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2011.18 · Cited by 59
Fazli, T., & Stephens, B. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.047 · Cited by 35
Metadata
- Authors
- WESCHLER, C. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2000-12
- Volume
- 10
- Issue
- 4
- Pages
- 269-288
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2078807751
- Cited by
- 758
- References
- 47
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.