Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information: Indoor air quality, ventilation and health symptoms in schools
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
We reviewed the literature on Indoor Air Quality (IAQ), ventilation, and building-related health problems in schools and identified commonly reported building-related health symptoms involving schools until 1999. We collected existing data on ventilation rates, carbon dioxide (CO2) concentrations and symptom-relevant indoor air contaminants, and evaluated information on causal relationships between pollutant exposures and health symptoms. Reported ventilation and CO2 data strongly indicate that ventilation is inadequate in many classrooms, possibly leading to health symptoms. Adequate ventilation should be a major focus of design or remediation efforts. Total volatile organic compounds, formaldehyde (HCHO) and microbiological contaminants are reported. Low HCHO concentrations were unlikely to cause acute irritant symptoms (<0.05 ppm), but possibly increased risks for allergen sensitivities, chronic irritation, and cancer. Reported microbiological contaminants included allergens in deposited dust, fungi, and bacteria. Levels of specific allergens were sufficient to cause symptoms in allergic occupants. Measurements of airborne bacteria and airborne and surface fungal spores were reported in schoolrooms. Asthma and 'sick building syndrome' symptoms are commonly reported. The few studies investigating causal relationships between health symptoms and exposures to specific pollutants suggest that such symptoms in schools are related to exposures to volatile organic compounds (VOCs), molds and microbial VOCs, and allergens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Air quality guidelines for Europe
Lodge, J. P. (1988) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(88)90109-6 · Cited by 1,802
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876 · cited 1×
“Concentrations of CO 2 below 1000 ppm do not always guarantee that the ventilation rate is adequate for removal of air pollutants from other indoor sources (Seppänen et al. , 1999; Apte et al., 2000).”
Spengler, J. D., McCarthy, J. F., & Samet, J. M. (2000) · Cited by 574
Health Effects and Sources of Indoor Air Pollution. Part I
Samet, J. M., Marbury, M. C., & Spengler, J. D. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.6.1486 · Cited by 541
APTE, M. G., FISK, W. J., & DAISEY, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341
Self-citationReview of Quantitative Standards and Guidelines for Fungi in Indoor Air
Rao, C. Y., Burge, H. A., & Chang, J. C. S. (1996) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1996.10467526 · Cited by 283
Proceedings of the 8th International Conference on Indoor Air Quality and Climate
Santos, A. M. B., & Gunnarsen, L. (1999) · Indoor Air · Cited by 274
Munir, A. K. M., Einarsson, R., Schou, C., & Dreborg, S. K. G. (1993) · Journal of Allergy and Clinical Immunology · doi:10.1016/0091-6749(93)90221-z · Cited by 227
Increased risk of allergy in children due to formaldehyde exposure in homes
Garrett, M., Hooper, M., Hooper, B., Rayment, P., & Abramson, M. (1999) · Allergy · doi:10.1034/j.1398-9995.1999.00763.x · Cited by 215
Norback, D., Torgen, M., & Edling, C. (1990) · Occupational and Environmental Medicine · doi:10.1136/oem.47.11.733 · Cited by 202
Health Effects and Sources of Indoor Air Pollution. Part II
Samet, J. M., Marbury, M. C., & Spengler, J. D. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/137.1.221 · Cited by 176
Building-Associated Risk of Febrile Acute Respiratory Diseases in Army Trainees
Brundage, J. F. (1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03720140028029 · Cited by 158
Airborne Beta-1,3-Glucan May Be Related to Symptoms in Sick Buildings
Rylander, R., Persson, K., Goto, H., Yuasa, K., & Tanaka, S. (1992) · Indoor Environment · doi:10.1177/1420326x9200100502 · Cited by 125
Subjective Indoor Air Quality in Schools in Relation to Exposure
Smedje, G., Norback, D., & Edling, C. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.00009.x · Cited by 119
Indoor Air '96. Proceedings of the 7th International Conference on Indoor Air Quality and Climate
Brohus, H., Knudsen, H. N., Nielsen, P. V., Clausen, G., & Fanger, P. O. (1996) · Indoor Air · Cited by 111
Spengler, J. D., McCarthy, J. F., & Fisk, W. J. (1999) · Cited by 101
Gravesen, S., Larsen, L., Gyntelberg, F., & Skov, P. (1986) · Allergy · doi:10.1111/j.1398-9995.1986.tb00337.x · Cited by 90
Dybendal, T., Vik, H., & Elsayed, S. (1989) · Allergy · doi:10.1111/j.1398-9995.1989.tb04171.x · Cited by 81
Proceedings of Indoor Air 2008, the 11th International Conference on Indoor Air Quality and Climate
Strøm-Tejsen, P., Olesen, B. W., Wargocki, P. L., Zukowska, D., & Toftum, J. (2008) · Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) · Cited by 77
Respiratory Symptoms and Infections among Children in a Day-Care Center with Mold Problems
Koskinen, O. M., Husman, T. M., Hyvärinen, A., Reponen, T. A., & Nevalainen, A. I. (1995) · Indoor Air · doi:10.1111/j.1600-0668.1995.t01-3-00002.x · Cited by 60
Norbäck, D. (1995) · Indoor Air · doi:10.1111/j.1600-0668.1995.00003.x · Cited by 58
Two Moldy Day-care Centers: a Follow-up Study of Respiratory Symptoms and Infections
Koskinen, O. M., Husman, T. M., Hyvärinen, A., Reponen, T. A., & Nevalainen, A. I. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.00005.x · Cited by 48
Dybendal, T., & Elsayed, S. (1992) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.1992.tb00136.x · Cited by 46
House dust mite allergen (Der p I) and respiratory symptoms in children: a case‐control study
Verhoeff, A. P., Strien, R. T. V., Wijnen, J. H. V., & Brunekreef, B. (1994) · Clinical & Experimental Allergy · doi:10.1111/j.1365-2222.1994.tb02744.x · Cited by 38
Commercial building ventilation rates and particle concentrations
Turk, B. H., Grimsrud, D. T., Brown, J. T., et al. (1989) · eScholarship (California Digital Library) · Cited by 38
Lawrence Berkeley National Lab., E. A. E. D., Daisey, J. M., USDOE Assistant Secretary for Energy Efficiency and Renewable Energy, W., & Angell, W. (1998) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/291031 · Cited by 37
Self-citationPlatts-Mills, T. A. E., Sporik, R., Ingram, J. M., & Honsinger, R. (1995) · International Archives of Allergy and Immunology · doi:10.1159/000237008 · Cited by 33
Dotterud, L. K., Vorland, L. H., & Falk, E. S. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.t01-2-00002.x · Cited by 21
Willers, S., Andersson, S., Andersson, R., Grantén, J., Sverdrup, C., & Rosell, L. (1996) · Indoor and Built Environment · doi:10.1177/1420326x9600500406 · Cited by 21
Indoor allergens: Identification and quantification
Reed, C. E., & Swanson, M. C. (1986) · Environment International · doi:10.1016/0160-4120(86)90021-8 · Cited by 14
Cited by
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Al horr, Y., Arif, M., Katafygiotou, M., Mazroei, A., Kaushik, A., & Elsarrag, E. (2016) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2016.03.006 · Cited by 817
Barrett, P., Davies, F., Zhang, Y., & Barrett, L. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.013 · Cited by 706
Metadata
- Authors
- Daisey, J. M., Angell, W. J., & Apte, M. G.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2003-02-28
- Volume
- 13
- Issue
- 1
- Pages
- 53-64
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2109503832
- Cited by
- 977
- References
- 30
- FWCI
- 14.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.