Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information: Indoor air quality, ventilation and health symptoms in schools
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
We reviewed the literature on Indoor Air Quality (IAQ), ventilation, and building-related health problems in schools and identified commonly reported building-related health symptoms involving schools until 1999. We collected existing data on ventilation rates, carbon dioxide (CO2) concentrations and symptom-relevant indoor air contaminants, and evaluated information on causal relationships between pollutant exposures and health symptoms. Reported ventilation and CO2 data strongly indicate that ventilation is inadequate in many classrooms, possibly leading to health symptoms. Adequate ventilation should be a major focus of design or remediation efforts. Total volatile organic compounds, formaldehyde (HCHO) and microbiological contaminants are reported. Low HCHO concentrations were unlikely to cause acute irritant symptoms (<0.05 ppm), but possibly increased risks for allergen sensitivities, chronic irritation, and cancer. Reported microbiological contaminants included allergens in deposited dust, fungi, and bacteria. Levels of specific allergens were sufficient to cause symptoms in allergic occupants. Measurements of airborne bacteria and airborne and surface fungal spores were reported in schoolrooms. Asthma and 'sick building syndrome' symptoms are commonly reported. The few studies investigating causal relationships between health symptoms and exposures to specific pollutants suggest that such symptoms in schools are related to exposures to volatile organic compounds (VOCs), molds and microbial VOCs, and allergens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Air quality guidelines for Europe
Lodge, J. P. (1988) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(88)90109-6 · Cited by 1,802
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876 · cited 1×
“Concentrations of CO 2 below 1000 ppm do not always guarantee that the ventilation rate is adequate for removal of air pollutants from other indoor sources (Seppänen et al. , 1999; Apte et al., 2000).”
Spengler, J. D., McCarthy, J. F., & Samet, J. M. (2000) · Cited by 574
Health Effects and Sources of Indoor Air Pollution. Part I
Samet, J. M., Marbury, M. C., & Spengler, J. D. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.6.1486 · Cited by 541
APTE, M. G., FISK, W. J., & DAISEY, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341
Self-citationReview of Quantitative Standards and Guidelines for Fungi in Indoor Air
Rao, C. Y., Burge, H. A., & Chang, J. C. S. (1996) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.1996.10467526 · Cited by 283
Proceedings of the 8th International Conference on Indoor Air Quality and Climate
Santos, A. M. B., & Gunnarsen, L. (1999) · Indoor Air · Cited by 274
Munir, A. K. M., Einarsson, R., Schou, C., & Dreborg, S. K. G. (1993) · Journal of Allergy and Clinical Immunology · doi:10.1016/0091-6749(93)90221-z · Cited by 227
Increased risk of allergy in children due to formaldehyde exposure in homes
Garrett, M., Hooper, M., Hooper, B., Rayment, P., & Abramson, M. (1999) · Allergy · doi:10.1034/j.1398-9995.1999.00763.x · Cited by 215
Norback, D., Torgen, M., & Edling, C. (1990) · Occupational and Environmental Medicine · doi:10.1136/oem.47.11.733 · Cited by 202
Cited by
Formaldehyde in the Indoor Environment
Salthammer, T., Mentese, S., & Marutzky, R. (2010) · Chemical Reviews · doi:10.1021/cr800399g · Cited by 1,808
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Al horr, Y., Arif, M., Katafygiotou, M., Mazroei, A., Kaushik, A., & Elsarrag, E. (2016) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2016.03.006 · Cited by 817
Barrett, P., Davies, F., Zhang, Y., & Barrett, L. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.013 · Cited by 706
Ventilation rates in schools and pupils’ performance
Bakó-Biró, Z., Clements-Croome, D. J., Kochhar, N., Awbi, H. B., & Williams, M. J. (2012) · Building and Environment · doi:10.1016/j.buildenv.2011.08.018 · Cited by 580
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
“(IEQ) in classrooms and student absence, health, or academic performance is limited and has been reviewed by Heath and Mendell (2002) and Daisey et al. (2003). There have been a few”
InfluentialSelf-citationIndoor aerosols: from personal exposure to risk assessment
Morawska, L., Afshari, A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Hänninen, O., Hofmann, W., Isaxon, C., Jayaratne, E. R., Pasanen, P., et al. (2013) · Indoor Air · doi:10.1111/ina.12044 · Cited by 442
Sadrizadeh, S., Yao, R., Yuan, F., Awbi, H., Bahnfleth, W., Bi, Y., Cao, G., Croitoru, C., de Dear, R., Haghighat, F., et al. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104908 · Cited by 375
Morawska, L., Ayoko, G. A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Clifford, S., Fu, S. C., Hänninen, O., He, C., Isaxon, C., et al. (2017) · Environment International · doi:10.1016/j.envint.2017.07.025 · Cited by 374
Oliveira, M., Slezakova, K., Delerue-Matos, C., Pereira, M. C., & Morais, S. (2019) · Environment International · doi:10.1016/j.envint.2018.12.052 · Cited by 332
Review of multi‐domain approaches to indoor environmental perception and behaviour
Schweiker, M., Ampatzi, E., Andargie, M. S., Andersen, R. K., Azar, E., Barthelmes, V. M., Berger, C., Bourikas, L., Carlucci, S., Chinazzo, G., et al. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106804 · Cited by 330
Association between substandard classroom ventilation rates and students’ academic achievement
Haverinen-Shaughnessy, U., Moschandreas, D. J., & Shaughnessy, R. J. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00686.x · Cited by 311
Providing better thermal and air quality conditions in school classrooms would be cost-effective
Wargocki, P., & Wyon, D. P. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.10.007 · Cited by 309
Mendell, M. J., Eliseeva, E. A., Davies, M. M., Spears, M., Lobscheid, A., Fisk, W. J., & Apte, M. G. (2013) · Indoor Air · doi:10.1111/ina.12042 · Cited by 299
Self-citationFormaldehyde Exposure and Asthma in Children: A Systematic Review
McGwin, G., Lienert, J., & Kennedy, J. I. (2010) · Environmental Health Perspectives · doi:10.1289/ehp.0901143 · Cited by 281
Indoor Air Quality and Sources in Schools and Related Health Effects
Annesi-Maesano, I., Baiz, N., Banerjee, S., Rudnai, P., Rive, S., & the SINPHONIE Group (2013) · Journal of Toxicology and Environmental Health, Part B · doi:10.1080/10937404.2013.853609 · Cited by 281
Indoor air quality in Michigan schools
Godwin, C., & Batterman, S. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00459.x · Cited by 263
The relationships between classroom air quality and children’s performance in school
Wargocki, P., Porras-Salazar, J. A., Contreras-Espinoza, S., & Bahnfleth, W. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106749 · Cited by 263
Hassanvand, M. S., Naddafi, K., Faridi, S., Nabizadeh, R., Sowlat, M. H., Momeniha, F., Gholampour, A., Arhami, M., Kashani, H., Zare, A., et al. (2015) · Science of The Total Environment · doi:10.1016/j.scitotenv.2015.05.001 · Cited by 255
Santamouris, M., Synnefa, A., Asssimakopoulos, M., Livada, I., Pavlou, K., Papaglastra, M., Gaitani, N., Kolokotsa, D., & Assimakopoulos, V. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.04.002 · Cited by 253
Annesi-Maesano, I., Hulin, M., Lavaud, F., Raherison, C., Kopferschmitt, C., de Blay, F., André Charpin, D., & Denis, C. (2012) · Thorax · doi:10.1136/thoraxjnl-2011-200391 · Cited by 252
Braniš, M., Řezáčová, P., & Domasová, M. (2005) · Environmental Research · doi:10.1016/j.envres.2004.12.001 · Cited by 249
Reduction in Asthma Morbidity in Children as a Result of Home Remediation Aimed at Moisture Sources
Kercsmar, C. M., Dearborn, D. G., Schluchter, M., Xue, L., Kirchner, H. L., Sobolewski, J., Greenberg, S. J., Vesper, S. J., & Allan, T. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.8742 · Cited by 245
“Previous studies have established the relationship of home dampness or mold to the presence of respiratory symptoms, such as bronchitis, cough, and other chest illnesses, but other studies have not (Daisey et al. 2003; Zureik et al. 2002).”
BackgroundIndoor air quality in schools and its relationship with children's respiratory symptoms
Madureira, J., Paciência, I., Rufo, J., Ramos, E., Barros, H., Teixeira, J. P., & de Oliveira Fernandes, E. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2015.07.028 · Cited by 234
“5 and PM10 should result in the increased prevalence of acute and chronic health effects, including asthma, among children (Daisey et al., 2003; Mendell and Heath, 2005).”
BackgroundJiang, C., Li, D., Zhang, P., Li, J., Wang, J., & Yu, J. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.03.004 · Cited by 232
Sofuoglu, S. C., Aslan, G., Inal, F., & Sofuoglu, A. (2011) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2010.08.008 · Cited by 222
“There are also other factors that influence indoor air qualty: schools are commonly associated with high population density, oor ventilation, lack of maintenance, and unsatisfactory cleaning Daisey et al., 2003; Smedje et al., 1997).”
BackgroundInfluentialKim, J. L., Elfman, L., Mi, Y., Wieslander, G., Smedje, G., & Norbäck, D. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00466.x · Cited by 213
Torresin, S., Pernigotto, G., Cappelletti, F., & Gasparella, A. (2018) · Indoor Air · doi:10.1111/ina.12457 · Cited by 210
The genotoxicity of ambient outdoor air, a review: Salmonella mutagenicity
Claxton, L. D., Matthews, P. P., & Warren, S. H. (2004) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2004.08.002 · Cited by 206
Personal exposure of children to air pollution
Ashmore, M. R., & Dimitroulopoulou, C. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.024 · Cited by 206
Influenza Virus Infectivity Is Retained in Aerosols and Droplets Independent of Relative Humidity
Kormuth, K. A., Lin, K., Prussin, A. J., Vejerano, E. P., Tiwari, A. J., Cox, S. S., Myerburg, M. M., Lakdawala, S. S., & Marr, L. C. (2018) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiy221 · Cited by 205
Aspergillus species in indoor environments and their possible occupational and public health hazards
Mousavi, B., Invasive Fungi Research Center, M. U. O. M. S., Hedayati, M. T., Invasive Fungi Research Center (IFRC), D. O. M. M. A. P. S. O. M., Hedayati, N., Ramsar International Branch, M. U. O. M. S., Ilkit, M., Division of Mycology, D. O. M., Syedmousavi, S., & Department of Medical Microbiology and Infectious Diseases, E. M. (2016) · Current Medical Mycology · doi:10.18869/acadpub.cmm.2.1.36 · Cited by 203
“Prolonged exposure to fungi might result in rhino chronic symptoms that are not principally allergic but cause irritation [66, 67].”
BackgroundClements-Croome, D. J., Awbi, H. B., Bakó-Biró, Z., Kochhar, N., & Williams, M. (2008) · Building and Environment · doi:10.1016/j.buildenv.2006.03.018 · Cited by 203
Characterization of indoor air quality in primary schools in Antwerp, Belgium
Stranger, M., Potgieter-Vermaak, S. S., & Van Grieken, R. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00545.x · Cited by 198
Barro, R., Regueiro, J., Llompart, M., & Garcia-Jares, C. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.10.117 · Cited by 198
Wargocki, P., & Wyon, D. P. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10390950 · Cited by 194
“Mendell and Heath (2005) cite seven studies, all performed in the last ten years, that indicate that “ventilation rates are substantially below recommended levels in many US and European schools,” the situation being similar in other parts of the world (Daisey et al. 2003; Boxem et al. 2006).”
BackgroundInfluentialWhat do we know about indoor air quality in school classrooms? A critical review of the literature
Chatzidiakou, L., Mumovic, D., & Summerfield, A. J. (2012) · Intelligent Buildings International · doi:10.1080/17508975.2012.725530 · Cited by 182
Total Concentrations of Virus and Bacteria in Indoor and Outdoor Air
Prussin, A. J., Garcia, E. B., & Marr, L. C. (2015) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.5b00050 · Cited by 181
Chithra, V. S., & Shiva Nagendra, S. M. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.01.016 · Cited by 180
de Gennaro, G., Dambruoso, P. R., Loiotile, A. D., Di Gilio, A., Giungato, P., Tutino, M., Marzocca, A., Mazzone, A., Palmisani, J., & Porcelli, F. (2014) · Environmental Chemistry Letters · doi:10.1007/s10311-014-0470-6 · Cited by 178
Indoor air quality and academic performance
Stafford, T. M. (2015) · Journal of Environmental Economics and Management · doi:10.1016/j.jeem.2014.11.002 · Cited by 178
Zhao, Z., Zhang, Z., Wang, Z., Ferm, M., Liang, Y., & Norbäck, D. (2008) · Environmental Health Perspectives · doi:10.1289/ehp.10576 · Cited by 177
“Western studies have shown that the school environment may exacerbate asthma symptoms, allergic reactions, and other respiratory symptoms (Daisey et al. 2003; Mendell and Heath 2005).”
BackgroundThe Potted-Plant Microcosm Substantially Reduces Indoor Air VOC Pollution: I. Office Field-Study
Wood, R. A., Burchett, M. D., Alquezar, R., Orwell, R. L., Tarran, J., & Torpy, F. (2006) · Water, Air, and Soil Pollution · doi:10.1007/s11270-006-9124-z · Cited by 172
“However, the health hazards of long-term exposures to such air pollution loads are of international concern as a human health issue (WHO, 2000; Mølhave and Krzyzanowski, 2003; Daisey et al., 2003; Wyon, 2004).”
BackgroundAsthma-Related School Absenteeism, Morbidity, and Modifiable Factors
Hsu, J., Qin, X., Beavers, S. F., & Mirabelli, M. C. (2016) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2015.12.012 · Cited by 165
Hassanvand, M. S., Naddafi, K., Faridi, S., Arhami, M., Nabizadeh, R., Sowlat, M. H., Pourpak, Z., Rastkari, N., Momeniha, F., Kashani, H., et al. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2013.10.048 · Cited by 160
“High levels of airborne PM in the schools environment have been reported in numerous studies (Daisey et al., 2003; Lee and Chang, 2000).”
BackgroundHeracleous, C., & Michael, A. (2019) · Journal of Building Engineering · doi:10.1016/j.jobe.2019.100917 · Cited by 159
Indoor allergens in school and day care environments
Salo, P. M., Sever, M. L., & Zeldin, D. C. (2009) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2009.05.012 · Cited by 135
Pegas, P. N., Nunes, T., Alves, C. A., Silva, J. R., Vieira, S. L. A., Caseiro, A., & Pio, C. A. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.03.059 · Cited by 102
Peng, Z., Deng, W., & Tenorio, R. (2017) · Sustainability · doi:10.3390/su9071180 · Cited by 109
Characterization of coarse particulate matter in school gyms
Braniš, M., & Šafránek, J. (2011) · Environmental Research · doi:10.1016/j.envres.2011.03.010 · Cited by 86
A Review of CO 2 Measurement Procedures in Ventilation Research
Mahyuddin, N., & Awbi, H. (2012) · International Journal of Ventilation · doi:10.1080/14733315.2012.11683961 · Cited by 73
Metadata
- Authors
- Daisey, J. M., Angell, W. J., & Apte, M. G.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2003-02-28
- Volume
- 13
- Issue
- 1
- Pages
- 53-64
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2109503832
- Cited by
- 977
- References
- 30
- FWCI
- 14.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.