The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Weighing of biomolecules, single cells and single nanoparticles in fluid
Open accessAbstract
Nanomechanical resonators enable the measurement of mass with extraordinary sensitivity. Previously, samples as light as 7 zeptograms (1 zg = 10(-21) g) have been weighed in vacuum, and proton-level resolution seems to be within reach. Resolving small mass changes requires the resonator to be light and to ring at a very pure tone-that is, with a high quality factor. In solution, viscosity severely degrades both of these characteristics, thus preventing many applications in nanotechnology and the life sciences where fluid is required. Although the resonant structure can be designed to minimize viscous loss, resolution is still substantially degraded when compared to measurements made in air or vacuum. An entirely different approach eliminates viscous damping by placing the solution inside a hollow resonator that is surrounded by vacuum. Here we demonstrate that suspended microchannel resonators can weigh single nanoparticles, single bacterial cells and sub-monolayers of adsorbed proteins in water with sub-femtogram resolution (1 Hz bandwidth). Central to these results is our observation that viscous loss due to the fluid is negligible compared to the intrinsic damping of our silicon crystal resonator. The combination of the low resonator mass (100 ng) and high quality factor (15,000) enables an improvement in mass resolution of six orders of magnitude over a high-end commercial quartz crystal microbalance. This gives access to intriguing applications, such as mass-based flow cytometry, the direct detection of pathogens, or the non-optical sizing and mass density measurement of colloidal particles.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The SMR is a cantilever-based microfluidic mass sensor that measures the buoyant mass (referred to hereafter simply as mass) of live single cells with a resolution near 50 fg, which is highly precise given that the average buoyant mass of a hematopoietic cell is ~75 pg11.”
From Drug sensitivity of single cancer cells is predicted by changes in mass accumulation rate (2016) · cites this paper as [11]
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,414
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,265
Nanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,038
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T. L., Fu, E. S., Helton, K. L., Nelson, K. E., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,982
Zeptogram-Scale Nanomechanical Mass Sensing
Yang, Y., Callegari, C., Feng, P. X. ‐., Ekinci, K. L., & Roukes, M. L. (2006) · Nano Letters · doi:10.1021/nl052134m · Cited by 1,045
Bioassay of prostate-specific antigen (PSA) using microcantilevers
Wu, G., Datar, R. H., Hansen, K. M., Thundat, T. G., Côté, R. J., & Majumdar, A. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-856 · Cited by 1,015
Amelinckx, S., Dyck, D. V., van Landuyt, P. J., & TENDELOO, G. V. (1996) · doi:10.1002/9783527620524.ch13 · Cited by 726
Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems
Ekinci, K. L., Yang, Y. T., & Roukes, M. L. (2004) · Journal of Applied Physics · doi:10.1063/1.1642738 · Cited by 696
Attogram detection using nanoelectromechanical oscillators
Ilic, B., Craighead, H. G., Krylov, S., Senaratne, W., Ober, C. K., & Neužil, P. (2004) · Journal of Applied Physics · doi:10.1063/1.1650542 · Cited by 586
Flagged first, then by citations
1 of the 35 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Items 401–500 of 1,000
Biosensor platform based on stress-improved piezoelectric membrane
Lü, X., Guo, Q., Xu, Z., Ren, W., & Cheng, Z. ‐. (2012) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2012.03.004 · Cited by 30
Internalization and cytotoxicity analysis of silicon-based microparticles in macrophages and embryos
Fernández-Rosas, E., Gómez, R., Ibáñez, E., Barrios, L., Duch, M., Estéve, J., Plaza, J. A., & Nogués, C. (2010) · Biomedical Microdevices · doi:10.1007/s10544-009-9393-6 · Cited by 30
MEMS/NEMS Devices and Applications
Young, D. J., Zorman, C. A., & Mehregany, M. (2010) · Springer eBooks · doi:10.1007/978-3-642-02525-9_12 · Cited by 29
Bioconjugation Strategies for Label-Free Optical Microcavity Sensors
Hunt, H. K., & Armani, A. M. (2013) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2013.2272916 · Cited by 29
Multifunctionalized Cantilever Systems for Electronic Nose Applications
Yoo, Y. K., Chae, M.-S., Kang, J. Y., Kim, T. S., Hwang, K. S., & Lee, J. H. (2012) · Analytical Chemistry · doi:10.1021/ac3015615 · Cited by 29
Kosaka, P. M., Tamayo, J., Ruz, J. J., Puertas, S., Polo, E., Grazú, V., de la Fuente, J. M., & Calleja, M. (2012) · The Analyst · doi:10.1039/c2an36192b · Cited by 29
Biophysical changes reduce energetic demand in growth factor–deprived lymphocytes
Hecht, V. C., Sullivan, L. B., Kimmerling, R. J., Kim, D., Hosios, A. M., Stockslager, M. A., Stevens, M. M., Kang, J. H., Wirtz, D., Heiden, M. G. V., et al. (2016) · The Journal of Cell Biology · doi:10.1083/jcb.201506118 · Cited by 29
Self-citationMechano-Optical Analysis of Single Cells with Transparent Microcapillary Resonators
Martín-Pérez, A., Ramos, D., Gil-Santos, E., García‐López, S., Yubero, M. L., Kosaka, P. M., Paulo, Á. S., Tamayo, J., & Calleja, M. (2019) · ACS Sensors · doi:10.1021/acssensors.9b02038 · Cited by 30
Cristaldi, D. A., Sargenti, A., Bonetti, S., Musmeci, F., Delprete, C., Bacchi, F., Pasqua, S., Cavallo, C., Bonsi, L., Alviano, F., et al. (2020) · Micromachines · doi:10.3390/mi11050465 · Cited by 29
A Review on Theory and Modelling of Nanomechanical Sensors for Biological Applications
Ruz, J. J., Malvar, Ó., Gil-Santos, E., Ramos, D., Calleja, M., & Tamayo, J. (2021) · Processes · doi:10.3390/pr9010164 · Cited by 30
Oncogenic HSP90 Facilitates Metabolic Alterations in Aggressive B-cell Lymphomas
Calvo-Vidal, M. N., Zamponi, N., Krumsiek, J., Stockslager, M. A., Revuelta, M. V., Phillip, J. M., Marullo, R., Tikhonova, E., Kotlov, N., Patel, J., et al. (2021) · Cancer Research · doi:10.1158/0008-5472.can-21-2734 · Cited by 29
Self-citationLee, I., Park, K., & Lee, J. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.01.046 · Cited by 29
Highly Sensitive Measurement of Liquid Density in Air Using Suspended Microcapillary Resonators
Malvar, Ó., Ramos, D., Martínez, C., Kosaka, P. M., Tamayo, J., & Calleja, M. (2015) · Sensors · doi:10.3390/s150407650 · Cited by 29
Microcantilever resonator arrays for immunodetection of β-lactoglobulin milk allergen
Ricciardi, C., Santoro, K., Stassi, S., Lamberti, C., Giuffrida, M. G., Arlorio, M., & Decastelli, L. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.07.150 · Cited by 29
Nanomechanical In Situ Monitoring of Proteolysis of Peptide by Cathepsin B
Kwon, T., Park, J., Yang, J., Yoon, D. S., Na, S., Kim, C., Suh, J., Huh, Y., Haam, S., & Eom, K. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006248 · Cited by 29
Analogy among microfluidics, micromechanics, and microelectronics
Li, S., & Cheng, C. (2013) · Lab on a Chip · doi:10.1039/c3lc50732g · Cited by 29
Fabrication of resonant micro cantilevers with integrated transparent fluidic channel
Khan, M. F., Schmid, S., Davis, Z. J., Dohn, S., & Boisen, A. (2011) · Microelectronic Engineering · doi:10.1016/j.mee.2011.02.096 · Cited by 29
Integrated microelectronic device for label-free nucleic acid amplification and detection
Hou, C.-S. J., Godin, M., Payer, K. R., Chakrabarti, R., & Manalis, S. R. (2007) · Lab on a Chip · doi:10.1039/b617082j · Cited by 29
Self-citationLenci, S., Tedeschi, L., Pieri, F., & Domenici, C. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.04.096 · Cited by 28
Beardslee, L. A., Josse, F. J., Heinrich, S. M., Dufour, I., & Brand, O. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.01.035 · Cited by 28
Are glycan biosensors an alternative to glycan microarrays?
Hushegyi, A., & Tkáč, J. (2014) · Analytical Methods · doi:10.1039/c4ay00692e · Cited by 28
Vibrational modes in MEMS resonators
Platz, D., & Schmid, U. (2019) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab4bad · Cited by 28
Magnetic Sensor Based on Giant Magneto-Impedance in Commercial Inductors
Wang, Z., Wen, T., Su, W., Hu, C., Chen, Y., Hu, Z., Wu, J., Zhou, Z., & Liu, M. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3007097 · Cited by 28
Patil, S. B., Vögtli, M., Webb, B. L. J., Mazza, G., Pinzani, M., Soh, Y., McKendry, R. A., & Ndieyira, J. W. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.174 · Cited by 28
Nanocardboard as a nanoscale analog of hollow sandwich plates
Chen, L., Nicaise, S. M., Lilley, D. E., Cortes, J., Jiao, P., Singh, J., Azadi, M., Lopez, G. G., Metzler, M. G., Purohit, P. K., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-06818-6 · Cited by 28
Portable Multiplex Optical Assays
Coskun, A. F., Topkaya, S. N., Yetisen, A. K., & Çetin, A. E. (2018) · Advanced Optical Materials · doi:10.1002/adom.201801109 · Cited by 29
Monolithic glass suspended microchannel resonators for enhanced mass sensing of liquids
Calmo, R., Lovera, A., Stassi, S., Chiadò, A., Scaiola, D., Bosco, F., & Ricciardi, C. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.12.019 · Cited by 28
Fluidic applications for atomic force microscopy (AFM) with microcantilever sensors
Kim, S., Kihm, K. D., & Thundat, T. G. (2010) · Experiments in Fluids · doi:10.1007/s00348-010-0830-3 · Cited by 28
Monitoring sessile droplet evaporation on a micromechanical device
Prasad, A., Lin, A., Rao, V. R., & Seshia, A. A. (2014) · The Analyst · doi:10.1039/c4an01389a · Cited by 27
Modena, M. M., Wang, Y., Riedel, D., & Burg, T. P. (2013) · Lab on a Chip · doi:10.1039/c3lc51058a · Cited by 27
Self-citationMcNaughton, B. H., Kinnunen, P., Smith, R. G., Pei, S. N., Torres-Isea, R. O., Kopelman, R., & Clarke, R. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.02.106 · Cited by 27
Wu, F., Wu, Y., Niu, Z., & Vollmer, F. (2016) · Sensors · doi:10.3390/s16081197 · Cited by 27
Zhao, J. X., Sun, C., Kacem, N., Wang, H., Gao, R., Liu, P., & Huang, Y. X. (2018) · Journal of Applied Physics · doi:10.1063/1.5050179 · Cited by 27
Murib, M. S., Martens, D., & Bienstman, P. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.12.127002 · Cited by 27
A data-driven approach to modeling cancer cell mechanics during microcirculatory transport
Balogh, P., Gounley, J. P., Roychowdhury, S., & Randles, A. P. (2021) · Scientific Reports · doi:10.1038/s41598-021-94445-5 · Cited by 29
Comprehensive Characterization of Molecular Interactions Based on Nanomechanics
Ghatkesar, M. K., Lang, H. P., Gerber, C., Hegner, M., & Braun, T. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003610 · Cited by 27
Energy dissipation in microfluidic beam resonators: Dependence on mode number
Sader, J. E., Lee, J., & Manalis, S. R. (2010) · Journal of Applied Physics · doi:10.1063/1.3514100 · Cited by 27
Self-citationMarvi, F., & Jafari, K. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3052001 · Cited by 27
Schemes for Tracking Resonance Frequency for Micro- and Nanomechanical Resonators
Bešić, H., Demir, A., Steurer, J., Luhmann, N., & Schmid, S. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.024023 · Cited by 26
Kartanas, T., Ostanin, V. P., Challa, P. K., Daly, R., Charmet, J., & Knowles, T. P. J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01174 · Cited by 26
Discrimination of tumor cell type based on cytometric detection of dielectric properties
Tang, D., Jiang, L., Xiang, N., & Ni, Z. (2022) · Talanta · doi:10.1016/j.talanta.2022.123524 · Cited by 26
Jin, Q., & Ren, Y. (2022) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2022.115834 · Cited by 26
Haiden, C., Wopelka, T., Jech, M., Keplinger, F., & Vellekoop, M. J. (2014) · Langmuir · doi:10.1021/la5016675 · Cited by 26
Zhao, J. X., Gao, R., Liu, S., & Huang, Y. X. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2258298 · Cited by 26
Pulled microcapillary tube resonators with electrical readout for mass sensing applications
Lee, D., Kim, J., Cho, N., Kang, T., Kauh, S., & Lee, J. (2016) · Scientific Reports · doi:10.1038/srep33799 · Cited by 26
Sliding Dynamic Behavior of a Nanobubble on a Surface
Wu, C.-J., Chu, K.-C., Sheng, Y., & Tsao, H. (2017) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.7b04924 · Cited by 26
Bhattacharya, S., & Li, S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2915292 · Cited by 26
Point-of-care (POC) devices by means of advanced MEMS
Karsten, S. L., Tarhan, M. C., Kudo, L. C., Collard, D., & Fujita, H. (2015) · Talanta · doi:10.1016/j.talanta.2015.04.032 · Cited by 26
Real-time detection of the chemokine CXCL12 in urine samples by surface plasmon resonance
Vega, B., Calle, A., Sánchez, A., Lechuga, L. M., Ortiz, A. M., Armelles, G., Rodrı́guez-Frade, J. M., & Mellado, M. (2013) · Talanta · doi:10.1016/j.talanta.2013.02.018 · Cited by 26
Krivitsky, V., Zverzhinetsky, M., & Patolsky, F. (2020) · ACS Nano · doi:10.1021/acsnano.9b10090 · Cited by 26
The promise of single-cell mechanophenotyping for clinical applications
Kozminsky, M., & Sohn, L. L. (2020) · Biomicrofluidics · doi:10.1063/5.0010800 · Cited by 25
Development of Environmental Nanosensors for Detection Monitoring and Assessment
Chakraborty, U., Kaur, G., & Chaudhary, G. R. (2021) · Springer eBooks · doi:10.1007/978-981-15-9239-3_5 · Cited by 25
Extending applications of AFM to fluidic AFM in single living cell studies
Qiu, Y., Chien, C., Maroulis, B., Bei, J., Gaitas, A., & Gong, B. (2022) · Journal of Cellular Physiology · doi:10.1002/jcp.30809 · Cited by 25
Thermoelastic dissipation of hollow micromechanical resonators
Tunvir, K., Ru, C. Q., & Mioduchowski, A. (2010) · Physica E Low-dimensional Systems and Nanostructures · doi:10.1016/j.physe.2010.05.015 · Cited by 25
High quality factor silicon cantilever driven by PZT actuator for resonant based mass detection
Lu, J. Q., Ikehara, T., Zhang, Y., Mihara, T., Itoh, T., & Maeda, R. (2008) · Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS · doi:10.1109/dtip.2008.4752953 · Cited by 25
Xiong, C., Zhou, X., He, Q., Huang, X., Wang, J., Peng, W., Chang, H., & Nie, Z. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03789 · Cited by 25
Yang, F., Riedel, R., del Pino, P., Pelaz, B., Said, A. H., Soliman, M. G., Pinnapireddy, S. R., Feliu, N., Parak, W. J., Bakowsky, U., et al. (2017) · Journal of Nanobiotechnology · doi:10.1186/s12951-017-0256-7 · Cited by 25
A coupled cantilever-microelectrode biosensor for enhanced pathogen detection
Tomkins, M. R., Chow, J., Lai, Y., & Docoslis, A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.09.020 · Cited by 24
Magnetostrictive particle based biosensors for in situ and real‐time detection of pathogens in water
Zhang, K., Fu, L., Zhang, L., Cheng, Z. ‐., & Huang, T. (2014) · Biotechnology and Bioengineering · doi:10.1002/bit.25279 · Cited by 24
Microsystems for Single‐Cell Analysis
Weiz, S. M., Medina‐Sánchez, M., & Schmidt, O. G. (2017) · Advanced Biosystems · doi:10.1002/adbi.201700193 · Cited by 24
MEMS/NEMS Devices and Applications
Feng, P. X. ‐., Young, D. J., & Zorman, C. A. (2017) · Springer handbooks · doi:10.1007/978-3-662-54357-3_13 · Cited by 24
Liu, Y., Schweizer, L. M., Wang, W., Reuben, R. L., Schweizer, M., & Shu, W. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.12.111 · Cited by 24
Tamayo, J., Calleja, M., Ramos, D., & Mertens, J. (2007) · Physical Review B · doi:10.1103/physrevb.76.180201 · Cited by 24
Optical racetrack resonator transduction of nanomechanical cantilevers
Sauer, V. T. K., Diao, Z., Freeman, M. R., & Hiebert, W. K. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/5/055202 · Cited by 27
Zhu, Z., Xiong, C., Xu, G., Liu, H., Zhou, X., Chen, S., Peng, W., & Nie, Z. (2011) · The Analyst · doi:10.1039/c0an00911c · Cited by 24
Abdolvahab, M. H., Fazeli, A., Halim, L. A., Sediq, A. S., Fazeli, M. R., & Schellekens, H. (2016) · Journal of Interferon & Cytokine Research · doi:10.1089/jir.2015.0108 · Cited by 24
Opto-acoustic sensing of fluids and bioparticles with optomechanofluidic resonators
Zhu, K., Han, K., Carmon, T., Fan, X., & Bahl, G. (2014) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2014-02237-4 · Cited by 24
Detecting the stiffness and mass of biochemical adsorbates by a resonator sensor
Zhang, Y. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.05.059 · Cited by 24
Koide, H., Yamaguchi, K., Sato, K., Aoshima, M., Kanata, S., Yonezawa, S., & Asai, T. (2023) · ACS Omega · doi:10.1021/acsomega.3c07226 · Cited by 23
Multimodal label-free detection and discrimination for small molecules using a nanoporous resonator
Park, J., Bang, D., Jang, K., Kim, E., Haam, S., & Na, S. (2014) · Nature Communications · doi:10.1038/ncomms4456 · Cited by 23
Factors Governing the Accuracy of Subvisible Particle Counting Methods
Quiroz, A. R., Finkler, C., Huwyler, J., Mahler, H., Schmidt, R., & Koulov, A. V. (2016) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2016.03.044 · Cited by 23
Kangül, M., Aydın, E., Gökçe, F., Zorlu, Ö., & Külah, H. (2017) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2017.2729624 · Cited by 23
Gagino, M., Katsikis, G., Olçum, S., Virot, L., Cochet, M., Thuaire, A., Manalis, S. R., & Agache, V. (2020) · ACS Sensors · doi:10.1021/acssensors.0c00394 · Cited by 23
Self-citationMeasurement of Navier Slip on Individual Nanoparticles in Liquid
Collis, J. F., Olçum, S., Chakraborty, D., Manalis, S. R., & Sader, J. E. (2021) · Nano Letters · doi:10.1021/acs.nanolett.1c00603 · Cited by 23
Self-citationHigh-resolution mass measurements of single budding yeast reveal linear growth segments
Cuny, A. P., Sapra, K. T., Martínez-Martín, D., Fläschner, G., Adams, J. D., Martin, S., Gerber, C., Rudolf, F., & Müller, D. J. (2022) · Nature Communications · doi:10.1038/s41467-022-30781-y · Cited by 23
High-resolution cantilever biosensor resonating at air–liquid in a microchannel
Park, J., Nishida, S., Lambert, P., Kawakatsu, H., & Fujita, H. (2011) · Lab on a Chip · doi:10.1039/c1lc20608g · Cited by 23
Size-independent Young's modulus of inverted conical GaAs nanowire resonators
Paulitschke, P., Seltner, N., Lebedev, A., Lorenz, H., & Weig, E. M. (2013) · Applied Physics Letters · doi:10.1063/1.4851897 · Cited by 23
The potential of naturally occurring lasing for biological and chemical sensors
Choi, S. H., & Kim, Y. L. (2014) · Biomedical Engineering Letters · doi:10.1007/s13534-014-0155-x · Cited by 23
Determination of Bacterial Antibiotic Resistance Based on Osmotic Shock Response
Knudsen, S. M., Muhlen, M. G. V., Schauer, D. B., & Manalis, S. R. (2009) · Analytical Chemistry · doi:10.1021/ac900968r · Cited by 23
Self-citationCorbin, E. A., Dorvel, B. R., Millet, L. J., King, W. P., & Bashir, R. (2014) · Lab on a Chip · doi:10.1039/c3lc51217g · Cited by 23
Nanotools and molecular techniques to rapidly identify and fight bacterial infections
Dinarelli, S., Girasole, M., Kasas, S., & Longo, G. (2016) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2016.01.005 · Cited by 23
Fully Differential Piezoelectric Button-Like Mode Disk Resonator for Liquid Phase Sensing
Ali, A., & Lee, J. E.-Y. (2018) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2018.2872923 · Cited by 23
Greenberg, Y. S., Pashkin, Y. A., & Il’ichev, E. V. (2012) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.0182.201204c.0407 · Cited by 23
Ayela, C., Dubourg, G., Pellet, C., & Haupt, K. (2014) · Advanced Materials · doi:10.1002/adma.201401088 · Cited by 22
Cell density modulates intracellular mass transport in neural networks
Cintora, P., Arikkath, J., Kandel, M. E., Popescu, G., & Best-Popescu, C. A. (2017) · Cytometry Part A · doi:10.1002/cyto.a.23111 · Cited by 22
Solid-State Nanopore Time-of-Flight Mass Spectrometer
Tsutsui, M., Yokota, K., Arima, A., He, Y., & Kawai, T. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01470 · Cited by 22
Li, W., Li, M., Wang, X., Xu, P., Yu, H., & Li, X. (2020) · Nano Today · doi:10.1016/j.nantod.2020.100932 · Cited by 22
Label-Free Protein Analysis Using Liquid Chromatography with Gravimetric Detection
Kartanas, T., Levin, A., Toprakcioglu, Z., Scheidt, T., Hakala, T. A., Charmet, J., & Knowles, T. P. J. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04149 · Cited by 22
Review on mechanics of fluid-conveying nanotubes
Jin, Q., & Ren, Y. (2023) · International Journal of Engineering Science · doi:10.1016/j.ijengsci.2023.104007 · Cited by 22
Detection of molecular binding via charge-induced mechanical response of optical fibers
Guan, Y., Shan, X., Wang, S., Zhang, P., & Tao, N. J. (2014) · Chemical Science · doi:10.1039/c4sc01188k · Cited by 22
Field-effect control of electrokinetic ion transport in a nanofluidic channel
Singh, K. P., Kumari, K., & Kumar, M. (2011) · Journal of Applied Physics · doi:10.1063/1.3651634 · Cited by 20
Zhang, N.-H., Meng, W.-L., & Tan, Z.-Q. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.023 · Cited by 22
Nejadnik, M. R., & Jiskoot, W. (2014) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24206 · Cited by 24
Bai, S., Landsman, P., Spencer, A., DeCollibus, D. P., Vega, F., Temel, D. B., Houde, D. J., Henderson, O., & Brader, M. L. (2015) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2015.10.012 · Cited by 22
Khalili, A. A., Ahmad, M. R., Takeuchi, M., Nakajima, M., Hasegawa, Y., & Zulkifli, R. M. (2016) · Applied Sciences · doi:10.3390/app6020040 · Cited by 22
Vy, N. D., Dat, L. T., & Iida, T. (2016) · Applied Physics Letters · doi:10.1063/1.4960380 · Cited by 22
Measuring the mass, volume, and density of microgram-sized objects in fluid
Oskui, S. M., Bhakta, H. C., Diamante, G., Liu, H. H., Schlenk, D., & Grover, W. H. (2017) · PLoS ONE · doi:10.1371/journal.pone.0174068 · Cited by 22
Ramakrishnan, S. K., Martin, M., Cloître, T., Agarwal, V., Cuisinier, F., & Gergely, C. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.05.154 · Cited by 22
Temperature-dependent thermomechanical noise spectra of doped silicon microcantilevers
Lee, J., Goericke, F. T., & King, W. P. (2007) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2007.10.028 · Cited by 22
Energy Dissipation in Fluid Coupled Nanoresonators: The Effect of Phonon-Fluid Coupling
De, S., & Aluru, N. R. (2017) · ACS Nano · doi:10.1021/acsnano.7b06469 · Cited by 21
Metadata
- Authors
- Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R.
- Affiliations
- Massachusetts Institute of Technology (US)
- Innovative Micro Technology (United States) (US)
- Corresponding author
- Manalis, Scott R.
- Venue
- Nature
- Published
- 2007-04
- Volume
- 446
- Issue
- 7139
- Pages
- 1066-1069
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2149562261
- Cited by
- 1,213
- References
- 35
- Citations by year
- 2026: 25 · 2025: 34 · 2024: 39 · 2023: 46 · 2022: 39 · 2021: 58 · 2020: 68 · 2019: 70 · 2018: 75 · 2017: 65 · 2016: 78 · 2015: 78 · 2014: 85 · 2013: 81 · 2012: 84
- FWCI
- 42.64
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion, other-oa)
- TUbilio (Technical University of Darmstadt) (submittedVersion)
- Funders
- National Institutes of Health (5p50gm068762-10)
- National Institute of General Medical Sciences (P50-GM068762)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Acoustic Wave Resonator Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- nanomechanical resonators, suspended microchannel resonators, viscous damping, microfluidic channels, protein adsorption, quality factor, silicon resonators, medical diagnostics, environmental monitoring
- MeSH terms
- Bacteria, Biological Products, Cells, Colloids, Molecular Weight, Proteins, Quartz, Solutions, Vacuum, Microfluidics, Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review