The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Weighing of biomolecules, single cells and single nanoparticles in fluid
Open accessAbstract
Nanomechanical resonators enable the measurement of mass with extraordinary sensitivity. Previously, samples as light as 7 zeptograms (1 zg = 10(-21) g) have been weighed in vacuum, and proton-level resolution seems to be within reach. Resolving small mass changes requires the resonator to be light and to ring at a very pure tone-that is, with a high quality factor. In solution, viscosity severely degrades both of these characteristics, thus preventing many applications in nanotechnology and the life sciences where fluid is required. Although the resonant structure can be designed to minimize viscous loss, resolution is still substantially degraded when compared to measurements made in air or vacuum. An entirely different approach eliminates viscous damping by placing the solution inside a hollow resonator that is surrounded by vacuum. Here we demonstrate that suspended microchannel resonators can weigh single nanoparticles, single bacterial cells and sub-monolayers of adsorbed proteins in water with sub-femtogram resolution (1 Hz bandwidth). Central to these results is our observation that viscous loss due to the fluid is negligible compared to the intrinsic damping of our silicon crystal resonator. The combination of the low resonator mass (100 ng) and high quality factor (15,000) enables an improvement in mass resolution of six orders of magnitude over a high-end commercial quartz crystal microbalance. This gives access to intriguing applications, such as mass-based flow cytometry, the direct detection of pathogens, or the non-optical sizing and mass density measurement of colloidal particles.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The SMR is a cantilever-based microfluidic mass sensor that measures the buoyant mass (referred to hereafter simply as mass) of live single cells with a resolution near 50 fg, which is highly precise given that the average buoyant mass of a hematopoietic cell is ~75 pg11.”
From Drug sensitivity of single cancer cells is predicted by changes in mass accumulation rate (2016) · cites this paper as [11]
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,414
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,265
Nanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,038
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T. L., Fu, E. S., Helton, K. L., Nelson, K. E., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,982
Zeptogram-Scale Nanomechanical Mass Sensing
Yang, Y., Callegari, C., Feng, P. X. ‐., Ekinci, K. L., & Roukes, M. L. (2006) · Nano Letters · doi:10.1021/nl052134m · Cited by 1,045
Bioassay of prostate-specific antigen (PSA) using microcantilevers
Wu, G., Datar, R. H., Hansen, K. M., Thundat, T. G., Côté, R. J., & Majumdar, A. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-856 · Cited by 1,015
Amelinckx, S., Dyck, D. V., van Landuyt, P. J., & TENDELOO, G. V. (1996) · doi:10.1002/9783527620524.ch13 · Cited by 726
Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems
Ekinci, K. L., Yang, Y. T., & Roukes, M. L. (2004) · Journal of Applied Physics · doi:10.1063/1.1642738 · Cited by 696
Attogram detection using nanoelectromechanical oscillators
Ilic, B., Craighead, H. G., Krylov, S., Senaratne, W., Ober, C. K., & Neužil, P. (2004) · Journal of Applied Physics · doi:10.1063/1.1650542 · Cited by 586
Cited by
Sorted by citations
Items 501–600 of 1,000
Metabolism, bioenergetics and thermal physiology: influences of the human intestinal microbiota
Armstrong, L. E., Casa, D. J., & Belval, L. N. (2019) · Nutrition Research Reviews · doi:10.1017/s0954422419000076 · Cited by 21
Vibrational analysis of Ag, Cu and Ni nanobeams using a hybrid continuum-atomistic model
Pourkermani, A. G., Azizi, B., & Pishkenari, H. N. (2019) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2019.105208 · Cited by 21
Nanofabrication enabled lab-on-a-chip technology for the manipulation and detection of bacteria
Li, L., Wang, C., Nie, Y., Yao, B., & Hu, H. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115905 · Cited by 22
Parametric amplification in a resonant sensing array
Yie, Z., Miller, N. J., Shaw, S. W., & Turner, K. L. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/3/035004 · Cited by 21
Collin, E., Kofler, J., Lakhloufi, S., Sébastien Pairis, E., Bunkov, Y. M., & Godfrin, H. (2010) · Journal of Applied Physics · doi:10.1063/1.3391901 · Cited by 21
Slippage and Boundary Layer Probed in an Almost Ideal Gas by a Nanomechanical Oscillator
Defoort, M., Lulla, K. J., Crozes, T., Maillet, O., Bourgeois, O., & Collin, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.136101 · Cited by 21
Millet, L. J., Corbin, E. A., Free, R., Park, K., Kong, H., King, W. P., & Bashir, R. (2012) · Small · doi:10.1002/smll.201200470 · Cited by 21
Recent advancements in microfluidics that integrate electrical sensors for whole blood analysis
Kuan, D.-H., & Huang, N. (2020) · Analytical Methods · doi:10.1039/d0ay00413h · Cited by 21
Operating Nanobeams in a Quantum Fluid
Bradley, D. I., George, R., Guénault, A. M., Haley, R. P., Kafanov, S., Noble, M. T., Pashkin, Y. A., Pickett, G. R., Poole, M., Prance, J. R., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-04842-y · Cited by 20
Liang, M., Zhong, J., & Ai, Y. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202200628 · Cited by 20
Atomic force microscopy: A powerful molecular toolkit in nanoproteomics
Dufrêne, Y. F. (2009) · PROTEOMICS · doi:10.1002/pmic.200800972 · Cited by 20
Optofluidic refractometer using resonant optical tunneling effect
Jian, A., Zhang, X., Zhu, W., & Yu, M. (2010) · Biomicrofluidics · doi:10.1063/1.3502671 · Cited by 20
Fluorescence Techniques for Determination of the Membrane Potentials in High Throughput Screening
Przybyło, M., Borowik, T., & Langner, M. (2010) · Journal of Fluorescence · doi:10.1007/s10895-010-0665-6 · Cited by 20
Physicochemical Characterization of Polymer Nanoparticles: Challenges and Present Limitations
Clogston, J. D., Crist, R. M., & McNeil, S. E. (2016) · Springer eBooks · doi:10.1007/978-3-319-41421-8_7 · Cited by 20
A resonant cantilever based particle sensor with particle-size selection function
Bao, Y., Cai, S., Yu, H., Xu, T., Xu, P., & Li, X. (2018) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aabdac · Cited by 20
Patil, S. B., Al-Jehani, R. M., Etayash, H., Turbé, V., Jiang, K., Bailey, J., Al‐Akkad, W., Soudy, R., Kaur, K., McKendry, R. A., et al. (2018) · Communications Biology · doi:10.1038/s42003-018-0179-3 · Cited by 20
Patocka, F., Schlögl, M., Schneidhofer, C., Dörr, N., Schneider, M., & Schmid, U. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.126957 · Cited by 20
Enhanced Binding Efficiency of Microcantilever Biosensor for the Detection of Yersinia
Liu, X., Wang, L., Zhao, J., Zhu, Y., Yang, J., & Yang, F. (2019) · Sensors · doi:10.3390/s19153326 · Cited by 20
Du, L., Chen, W., Tian, Y., Zhu, P., Wu, C., & Wang, P. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.127949 · Cited by 20
Lončar, M. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.187 · Cited by 20
Radiation-Pressure-Antidamping Enhanced Optomechanical Spring Sensing
Pan, F., Cui, K., Bai, G., Feng, X., Liu, F., Zhang, W., & Huang, Y. (2018) · ACS Photonics · doi:10.1021/acsphotonics.8b00968 · Cited by 21
Review of applications of self‐excited oscillations to highly sensitive vibrational sensors
Yabuno, H. (2019) · ZAMM ‐ Journal of Applied Mathematics and Mechanics / Zeitschrift für Angewandte Mathematik und Mechanik · doi:10.1002/zamm.201900009 · Cited by 19
Avoiding transduction-induced heating in suspended microchannel resonators using piezoelectricity
Maillard, D., Pastina, A. D., Abazari, A. M., & Villanueva, L. G. (2021) · Microsystems & Nanoengineering · doi:10.1038/s41378-021-00254-1 · Cited by 19
Scanning Probe Microscope-Based Fluid Dispensing
Ghatkesar, M. K., Garza, H. H. P., Heuck, F. C. A., & Staufer, U. (2014) · Micromachines · doi:10.3390/mi5040954 · Cited by 19
Detecting the mass and position of an adsorbate on a drum resonator
Zhang, Y., & Zhao, Y. (2014) · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rspa.2014.0418 · Cited by 19
A cantilever biosensor based on a gap method for detecting Escherichia coli in real time
Leahy, S., & Lai, Y. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.02.144 · Cited by 19
Bioapplications of acoustic crystals, a review
Hussain, M., Rupp, F., Wendel, H. P., & Gehring, F. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.02.009 · Cited by 19
Guénault, A. M., Guthrie, A., Haley, R. P., Kafanov, S. G., Pashkin, Y. A., Pickett, G. R., Poole, M., Schanen, R., Tsepelin, V., Zmeev, D. E., et al. (2019) · Physical review. B./Physical review. B · doi:10.1103/physrevb.100.020506 · Cited by 19
Lee, J., & King, W. P. (2008) · Review of Scientific Instruments · doi:10.1063/1.2913337 · Cited by 19
Static mode microfluidic cantilevers for detection of waterborne pathogens
Bridle, H. L., Wang, W., Gavriilidou, D., Amalou, F., Hand, D. P., & Shu, W. (2016) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2016.05.011 · Cited by 18
Katsikis, G., Hwang, I. E., Wang, W., Bhat, V. S., McIntosh, N. L., Karim, O. A., Blus, B. J., Sha, S., Agache, V., Wolfrum, J. M., et al. (2022) · Nano Letters · doi:10.1021/acs.nanolett.1c04092 · Cited by 20
Self-citationFigueroa, B., Xu, F. X., Hu, R., Men, S., & Fu, D. (2022) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.2c04355 · Cited by 18
Schubert, M. G., Tang, T., Goodchild-Michelman, I. M., Ryon, K. A., Henriksen, J. R., Chavkin, T. A., Wu, Y., Miettinen, T. P., Wychen, S. V., Dahlin, L. R., et al. (2024) · Applied and Environmental Microbiology · doi:10.1128/aem.00841-24 · Cited by 19
Self-citationMultifunctional nanocomposite membrane for chemomechanical transducer
Kang, T. J., Lim, D., Nam, J., & Kim, Y. H. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.03.056 · Cited by 18
Sahoo, A. K., Sharma, S., Chattopadhyay, A., & Ghosh, S. S. (2012) · Nanoscale · doi:10.1039/c2nr11837h · Cited by 18
Aïzel, K., Agache, V., Pudda, C., Bottausci, F., Fraisseix, C., Bruniaux, J., Navarro, F. P., & Fouillet, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50835h · Cited by 18
Nanomechanical actuation driven by light-induced DNA fuel
Eom, K., Jung, H., Lee, G., Park, J., Nam, K., Lee, S. W., Yoon, D. S., Yang, J., & Kwon, T. (2011) · Chemical Communications · doi:10.1039/c1cc12893k · Cited by 18
Pandya, H. J., Kanakasabapathy, M. K., Verma, S., Chug, M. K., Memić, A., Gadjeva, M. G., & Shafiee, H. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.035 · Cited by 38
Fitzpatrick, K. J., Rohlf, H. J., Sutherland, T. D., Koo, K. M., Beckett, S., Okello, W. O., Keyburn, A. L., Morgan, B. S., Drigo, B., Trau, M., et al. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01973 · Cited by 18
Forecasting bifurcation morphing: application to cantilever-based sensing
Lim, J., & Epureanu, B. I. (2011) · Nonlinear Dynamics · doi:10.1007/s11071-011-0146-8 · Cited by 18
Stockslager, M. A., Olçum, S., Knudsen, S. M., Kimmerling, R. J., Cermak, N., Payer, K. R., Agache, V., & Manalis, S. R. (2019) · Review of Scientific Instruments · doi:10.1063/1.5100861 · Cited by 18
Self-citationCooperative nutrient accumulation sustains growth of mammalian cells
Son, S., Stevens, M. M., Chao, H. X., Thoreen, C. C., Hosios, A. M., Schweitzer, L. D., Weng, Y., Wood, K. C., Sabatini, D. M., Heiden, M. G. V., et al. (2015) · Scientific Reports · doi:10.1038/srep17401 · Cited by 18
Self-citationHe, Y., Xu, W., Yan, K., Zhao, L., Wang, J., Li, K., Liu, J., & Jiang, H. (2025) · Droplet · doi:10.1002/dro2.165 · Cited by 17
Peng, J., Zhao, N., Lin, S., Wang, W., Zhang, M., Su, Y., Xie, R., Ju, X., Liu, Z., & Chu, L. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.127138 · Cited by 17
Real-Time Sensing with Multiplexed Optomechanical Resonators
Lamberti, F. R., Palanchoke, U., Geurts, T. P. J., Gély, M., Regord, S., Banniard, L., Sansa, M., Favero, I., Jourdan, G., & Hentz, S. (2022) · Nano Letters · doi:10.1021/acs.nanolett.1c04017 · Cited by 17
Koide, H., Saito, K., Yoshimatsu, K., Chou, B., Hoshino, Y., Yonezawa, S., Oku, N., Asai, T., & Shea, K. J. (2023) · Journal of Controlled Release · doi:10.1016/j.jconrel.2023.02.020 · Cited by 17
Cell size, density, and nutrient dependency of unicellular algal gravitational sinking velocities
Miettinen, T. P., Gomez, A. L., Wu, Y., Wu, W., Usherwood, T. R., Hwang, Y., Roller, B. R. K., Polz, M. F., & Manalis, S. R. (2024) · Science Advances · doi:10.1126/sciadv.adn8356 · Cited by 17
Self-citationDubourg, G., Fadel, L., Dufour, I., Pellet, C., & Ayela, C. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/9/095021 · Cited by 17
Svanbäck, S., Ehlers, H., Antikainen, O. K., & Yliruusi, J. K. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01033 · Cited by 17
Single Cell Mass Measurement Using Drag Force Inside Lab-on-Chip Microfluidics System
Rahman, M. H., Ahmad, M. R., Takeuchi, M., Nakajima, M., Hasegawa, Y., & Fukuda, T. (2015) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2015.2507064 · Cited by 17
Deformability-based cell selection with downstream immunofluorescence analysis
Bagnall, J., Byun, S., Miyamoto, D. T., Kang, J. H., Maheswaran, S., Stott, S. L., Toner, M., & Manalis, S. R. (2016) · Integrative Biology · doi:10.1039/c5ib00284b · Cited by 17
Self-citationSadAbadi, H., & Packirisamy, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-11300-2 · Cited by 17
Saygıner, O., Chiasera, A., Żur, L., Varas, S., Tran, L. T., Armellini, C., Ferrari, M., & Bursi, O. S. (2019) · Ceramics International · doi:10.1016/j.ceramint.2019.01.083 · Cited by 17
Mass and Force Sensing of an Adsorbate on a Beam Resonator Sensor
Zhang, Y., & Zhao, Y. (2015) · Sensors · doi:10.3390/s150714871 · Cited by 17
Label-free biomarker detection from whole blood
STERN, E. W., Vacic, A., Rajan, N. K., Criscione, J. M., Park, J. Y., Fahmy, T. M., & Reed, M. A. (2010) · IEEE International Conference on Solid-State and Integrated Circuit Technology · doi:10.1109/icsict.2010.5667621 · Cited by 19
On-chip read-out of picomechanical motion under ambient conditions
Putrino, G., Martyniuk, M. P., KEATING, A. J., Faraone, L., & Dell, J. M. (2014) · Nanoscale · doi:10.1039/c4nr05419a · Cited by 17
Microfluidics Technology for Systems Biology Research
Wang, C. J., & Levchenko, A. (2009) · Methods in molecular biology · doi:10.1007/978-1-59745-525-1_7 · Cited by 17
Eom, K., Yang, J., Park, J., Yoon, G., Sohn, Y. S., Park, S., Yoon, D. S., Na, S., & Kwon, T. (2009) · International Journal of Molecular Sciences · doi:10.3390/ijms10094009 · Cited by 17
Riordon, J., Nash, M., Jing, W., & Godin, M. (2014) · Biomicrofluidics · doi:10.1063/1.4867035 · Cited by 16
Self-citationFernandes, D. A. (2024) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.4c00137 · Cited by 17
Data-driven fingerprint nanoelectromechanical mass spectrometry
Sader, J. E., Gomez, A., Neumann, A. P., Nunn, A., & Roukes, M. L. (2024) · Nature Communications · doi:10.1038/s41467-024-51733-8 · Cited by 16
Zhang, Y., & Liu, Y. (2014) · Sensors · doi:10.3390/s140916296 · Cited by 16
Blanco-Gomez, G., & Agache, V. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2170820 · Cited by 16
Control of MEMS on the edge of instability
Burgner, C. B., Snyders, W. S., & Turner, K. L. (2011) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2011.5969197 · Cited by 16
Functional nanomaterial-based amplified bio-detection strategies
Jeon, J., Lim, D., & Nam, J. (2009) · Journal of Materials Chemistry · doi:10.1039/b816690k · Cited by 16
Soleymaniha, M., & Felts, J. R. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2016.04.063 · Cited by 16
Evaporation based micro pump integrated into a scanning force microscope probe
Heuck, F. C. A., Hug, T. S., Akiyama, T., Frederix, P. L. T. M., Engel, A. H., Meister, A., Heinzelmann, H., de Rooij, N. F., & Staufer, U. (2008) · Microelectronic Engineering · doi:10.1016/j.mee.2007.12.047 · Cited by 16
In-situ comprehensive calibration of a tri-port nano-electro-mechanical device
Collin, E., Defoort, M., Lulla, K. J., Moutonet, T., Heron, J.-S., Bourgeois, O., Bunkov, Y. M., & Godfrin, H. (2012) · Review of Scientific Instruments · doi:10.1063/1.4705992 · Cited by 16
High-Qmicromechanical resonators for mass sensing in dissipative media
Tappura, K., Pekko, P., & Seppä, H. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/6/065002 · Cited by 16
Asymptotic analysis of the Boltzmann–BGK equation for oscillatory flows
Nassios, J., & Sader, J. E. (2012) · Journal of Fluid Mechanics · doi:10.1017/jfm.2012.302 · Cited by 16
Design, fabrication and characterization of a piezoelectric MEMS diaphragm resonator mass sensor
Hu, Z., Hedley, J., Keegan, N., Spoors, J. A., Waugh, W., Gallacher, B. J., Boillot, F.-X., Collet, J., & McNeil, C. J. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/12/125019 · Cited by 16
Yun, M., Lee, I., Jeon, S., & Lee, J. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2287887 · Cited by 16
PARAMETER SWEEP STRATEGIES FOR SENSING USING BIFURCATIONS IN MEMS
Burgner, C. B., Miller, N. J., Shaw, S. W., & Turner, K. L. (2010) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2010.36 · Cited by 16
Single-Cell Pathogen Detection with a Reverse-Phase Immunoassay on Impedimetric Transducers
de la Rica, R., Baldi, A., Fernández‐Sánchez, C., & Matsui, H. (2009) · Analytical Chemistry · doi:10.1021/ac901210f · Cited by 16
Metabolic regulation of species-specific developmental ratesPreprint
Díaz-Cuadros, M., Miettinen, T. P., Sheedy, D., Díaz‐García, C. M., Gapon, S., Hubaud, A., Yellen, G., Manalis, S. R., Oldham, W. M., & Pourquié, O. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.08.27.457974 · Cited by 16
Self-citationHigh resolution imaging of viruses: Scanning probe microscopy and related techniques
Ахметова, А. И., & Yaminsky, I. V. (2021) · Methods · doi:10.1016/j.ymeth.2021.06.011 · Cited by 15
Nguyen, T.-K., Carpentier, O., Monchau, F., Chai, F., Hornez, J., & Hivart, P. (2018) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2018.04.012 · Cited by 15
Nanoelectromechanical Disk Resonators as Highly Sensitive Mass Sensors
Qaradaghi, V., Ramezany, A., Babu, S., Lee, J., & Pourkamali, S. (2018) · IEEE Electron Device Letters · doi:10.1109/led.2018.2871754 · Cited by 15
Nonlinear dynamic behavior of a clamped–clamped beam from BNC nanotube impacted by fullerene
Yang, L., Cai, K., Shi, J., Xie, Y. M., & Qin, Q. (2019) · Nonlinear Dynamics · doi:10.1007/s11071-019-04845-6 · Cited by 15
Yan, Y., Li, J.-X., Ma, X., & Wang, W. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.112836 · Cited by 15
Willaert, R., Kasas, S., Devreese, B. V., & Dietler, G. (2016) · Fermentation · doi:10.3390/fermentation2040018 · Cited by 16
MEMS thermal-piezoresistive resonators, thermal-piezoresistive oscillators, and sensors
Wei, L., You, Z., Kuai, X., Zhang, M., Yang, F., & Wang, X. (2022) · Microsystem Technologies · doi:10.1007/s00542-022-05391-9 · Cited by 15
Mass-based readout for agglutination assays
Chunara, R., Godin, M., Knudsen, S. M., & Manalis, S. R. (2007) · Applied Physics Letters · doi:10.1063/1.2806197 · Cited by 15
Self-citationOesterschulze, E., Kehrbusch, P., Radzio, B., Ilin, E. A., Thyssen, A., Deitmer, J. W., & Kehrbusch, J. (2012) · Lab on a Chip · doi:10.1039/c2lc21260a · Cited by 15
Cell-based sensors for quantifying the physiological impact of microsystems
Desai, S. P., & Joel Voldman, B. (2010) · Integrative Biology · doi:10.1039/c0ib00067a · Cited by 15
Kim, J., Kim, H. J., Cho, E., Shin, H.-J., Park, J. H., & Hwang, K. S. (2015) · Scientific Reports · doi:10.1038/srep17069 · Cited by 15
Micro- and Nanoscale Approaches in Antifungal Drug Discovery
Willaert, R. (2018) · Fermentation · doi:10.3390/fermentation4020043 · Cited by 18
Solid-State Microfluidics with Integrated Thin-Film Acoustic Sensors
Zhang, M., Huang, J., Lu, Y., Pang, W., Zhang, H., & Duan, X. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00412 · Cited by 15
Echographic and physical characterization of albumin-stabilized nanobubbles
Watanabe, A., Sheng, H., Endo, H., Feril, L. B., Irie, Y., Ogawa, K., Moosavi‐Nejad, S., & Tachibana, K. (2019) · Heliyon · doi:10.1016/j.heliyon.2019.e01907 · Cited by 15
Longitudinal bulk acoustic mass sensor
Hales, J. H., Teva, J., Boisen, A., & Davis, Z. J. (2009) · Applied Physics Letters · doi:10.1063/1.3168519 · Cited by 15
Thermomechanical behavior of a bimaterial microchannel cantilever subjected to periodic IR radiation
Miriyala, N., Khan, M. F., & Thundat, T. G. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.05.043 · Cited by 15
A single-lens universal interferometer: Towards a class of frugal optical devices
Munjal, P., & Singh, K. P. (2019) · Applied Physics Letters · doi:10.1063/1.5108587 · Cited by 14
Operating nanobeams in a quantum fluid
Bradley, D. I., George, R. E., Guénault, A. M., Haley, R. P., Kafanov, S., Noble, T., Pashkin, Y., Pickett, G. R., Poole, M., Prance, J. R., et al. (2017) · Lancaster EPrints (Lancaster University) · Cited by 14
Li, S., Xue, C., Li, Y., Chen, X., Zhao, Y., & Qin, K. (2023) · Electrophoresis · doi:10.1002/elps.202300177 · Cited by 14
Tethered-bead, immune sandwich assay
Silver, J. E., Li, Z., & Neuman, K. C. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.011 · Cited by 14
Using magnetic levitation for density-based detection of cooking oils
Zhu, C., Gao, L., Han, Y., Ouyang, Q., Zong, L., Li, L., Zhang, C., Liu, J., Yu, H., & Huang, W. (2019) · RSC Advances · doi:10.1039/c9ra02516b · Cited by 14
NAKAMURA, T., Yabuno, H., & Yano, M. (2019) · Nonlinear Dynamics · doi:10.1007/s11071-019-05287-w · Cited by 14
Krause, N., Kuhn, S., Frotscher, E., Nikels, F., Hawe, A., Garidel, P., & Menzen, T. (2021) · The AAPS Journal · doi:10.1208/s12248-020-00547-9 · Cited by 14
Mass and force sensing of an adsorbate on a string resonator
Zhang, Y., & Zhao, Y. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.06.047 · Cited by 14
Zhao, Q., Shirinzadeh, B., Cui, M., Sun, M., Liu, Y., & Zhao, X. J. (2015) · Journal of Applied Physics · doi:10.1063/1.4926852 · Cited by 14
Metadata
- Authors
- Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R.
- Affiliations
- Massachusetts Institute of Technology (US)
- Innovative Micro Technology (United States) (US)
- Corresponding author
- Manalis, Scott R.
- Venue
- Nature
- Published
- 2007-04
- Volume
- 446
- Issue
- 7139
- Pages
- 1066-1069
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2149562261
- Cited by
- 1,213
- References
- 35
- Citations by year
- 2026: 25 · 2025: 34 · 2024: 39 · 2023: 46 · 2022: 39 · 2021: 58 · 2020: 68 · 2019: 70 · 2018: 75 · 2017: 65 · 2016: 78 · 2015: 78 · 2014: 85 · 2013: 81 · 2012: 84
- FWCI
- 42.64
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion, other-oa)
- TUbilio (Technical University of Darmstadt) (submittedVersion)
- Funders
- National Institutes of Health (5p50gm068762-10)
- National Institute of General Medical Sciences (P50-GM068762)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Acoustic Wave Resonator Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- nanomechanical resonators, suspended microchannel resonators, viscous damping, microfluidic channels, protein adsorption, quality factor, silicon resonators, medical diagnostics, environmental monitoring
- MeSH terms
- Bacteria, Biological Products, Cells, Colloids, Molecular Weight, Proteins, Quartz, Solutions, Vacuum, Microfluidics, Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review