The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.
Weighing of biomolecules, single cells and single nanoparticles in fluid
Open accessAbstract
Nanomechanical resonators enable the measurement of mass with extraordinary sensitivity. Previously, samples as light as 7 zeptograms (1 zg = 10(-21) g) have been weighed in vacuum, and proton-level resolution seems to be within reach. Resolving small mass changes requires the resonator to be light and to ring at a very pure tone-that is, with a high quality factor. In solution, viscosity severely degrades both of these characteristics, thus preventing many applications in nanotechnology and the life sciences where fluid is required. Although the resonant structure can be designed to minimize viscous loss, resolution is still substantially degraded when compared to measurements made in air or vacuum. An entirely different approach eliminates viscous damping by placing the solution inside a hollow resonator that is surrounded by vacuum. Here we demonstrate that suspended microchannel resonators can weigh single nanoparticles, single bacterial cells and sub-monolayers of adsorbed proteins in water with sub-femtogram resolution (1 Hz bandwidth). Central to these results is our observation that viscous loss due to the fluid is negligible compared to the intrinsic damping of our silicon crystal resonator. The combination of the low resonator mass (100 ng) and high quality factor (15,000) enables an improvement in mass resolution of six orders of magnitude over a high-end commercial quartz crystal microbalance. This gives access to intriguing applications, such as mass-based flow cytometry, the direct detection of pathogens, or the non-optical sizing and mass density measurement of colloidal particles.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The SMR is a cantilever-based microfluidic mass sensor that measures the buoyant mass (referred to hereafter simply as mass) of live single cells with a resolution near 50 fg, which is highly precise given that the average buoyant mass of a hematopoietic cell is ~75 pg11.”
From Drug sensitivity of single cancer cells is predicted by changes in mass accumulation rate (2016) · cites this paper as [11]
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,414
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,265
Nanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,038
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T. L., Fu, E. S., Helton, K. L., Nelson, K. E., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,982
Zeptogram-Scale Nanomechanical Mass Sensing
Yang, Y., Callegari, C., Feng, P. X. ‐., Ekinci, K. L., & Roukes, M. L. (2006) · Nano Letters · doi:10.1021/nl052134m · Cited by 1,045
Bioassay of prostate-specific antigen (PSA) using microcantilevers
Wu, G., Datar, R. H., Hansen, K. M., Thundat, T. G., Côté, R. J., & Majumdar, A. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-856 · Cited by 1,015
Amelinckx, S., Dyck, D. V., van Landuyt, P. J., & TENDELOO, G. V. (1996) · doi:10.1002/9783527620524.ch13 · Cited by 726
Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems
Ekinci, K. L., Yang, Y. T., & Roukes, M. L. (2004) · Journal of Applied Physics · doi:10.1063/1.1642738 · Cited by 696
Attogram detection using nanoelectromechanical oscillators
Ilic, B., Craighead, H. G., Krylov, S., Senaratne, W., Ober, C. K., & Neužil, P. (2004) · Journal of Applied Physics · doi:10.1063/1.1650542 · Cited by 586
Cited by
Sorted by citations
Items 301–400 of 1,000
Modeling Piezoresistive Microcantilever Sensor Response to Surface Stress for Biochemical Sensors
Goericke, F. T., & King, W. P. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.920706 · Cited by 44
Mahmoud, M. A. E. (2016) · Critical reviews in solid state and materials sciences/CRC critical reviews in solid state and materials sciences · doi:10.1080/10408436.2016.1142858 · Cited by 44
A smart microelectromechanical sensor and switch triggered by gas
Bouchaala, A. M. S., Jaber, N. R., Shekhah, O., Chernikova, V., Eddaoudi, M., & Younis, M. I. (2016) · Applied Physics Letters · doi:10.1063/1.4955309 · Cited by 44
Brueckner, K., Niebelschütz, F., Tonisch, K., Michael, S., Dadgar, A., Krost, A., Cimalla, V., Ambacher, O., Stephan, R., & Hein, M. (2008) · Applied Physics Letters · doi:10.1063/1.3002296 · Cited by 44
Gil-Santos, E., Ramos, D., Pini, V., Calleja, M., & Tamayo, J. (2011) · Applied Physics Letters · doi:10.1063/1.3569588 · Cited by 44
Combining Resonant Piezoelectric Micromembranes with Molecularly Imprinted Polymers
Ayela, C., Vandevelde, F., Lagrange, D., Haupt, K., & Nicu, L. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200703881 · Cited by 44
Intracellular Silicon Chips in Living Cells
Gómez, R., Vázquez, P., Duch, M., Muriano, A., Pinacho, D. G., Sanvicens, N., Sánchez-Baeza, F. J., Boya, P., de la Rosa, E. J., Estéve, J., et al. (2009) · Small · doi:10.1002/smll.200901041 · Cited by 44
Roesch, A., Zölls, S., Stadler, D., Helbig, C., Wuchner, K., Kersten, G. F. A., Hawe, A., Jiskoot, W., & Menzen, T. (2021) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2021.12.011 · Cited by 44
Lee, S.-M., Hwang, K. S., Yoon, H., Yoon, D. S., Kim, S. K., Lee, Y.-S., & Kim, T. S. (2009) · Lab on a Chip · doi:10.1039/b902922b · Cited by 43
Toward Advancing Nano-Object Count Metrology: A Best Practice Framework
Brown, S. C., Boyko, V., Meyers, G. F., Voetz, M., & Wohlleben, W. (2013) · Environmental Health Perspectives · doi:10.1289/ehp.1306957 · Cited by 43
High-throughput sensing of freely flowing particles with optomechanofluidics
Han, K., Kim, J., & Bahl, G. (2016) · Optica · doi:10.1364/optica.3.000585 · Cited by 43
Maity, A., Sui, X., Jin, B., Pu, H., Bottum, K. J., Huang, X., Chang, J., Zhou, G., Lu, G., & Chen, J. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03226 · Cited by 43
Lucklum, R., Mukhin, N. V., Djafari‐Rouhani, B., & Pennec, Y. (2021) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2021.705194 · Cited by 43
Regulation of vascular smooth muscle cell autophagy by DNA nanotube-conjugated mTOR siRNA
You, Z., Qian, H., Wang, C., He, B., Yan, J., Mao, C., & Wang, G. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.07.015 · Cited by 42
Real-time monitoring of bacterial biofilms metabolic activity by a redox-reactive nanosensors array
Davidi, E., Zverzhinetsky, M., Krivitsky, V., & Patolsky, F. (2020) · Journal of Nanobiotechnology · doi:10.1186/s12951-020-00637-y · Cited by 43
Ultrasensitive nanomechanical mass sensor using hybrid opto-electromechanical systems
Jiang, C., Cui, Y., & Zhu, K. (2014) · Optics Express · doi:10.1364/oe.22.013773 · Cited by 42
Ultimate and practical limits of fluid-based mass detection with suspended microchannel resonators
Arlett, J., & Roukes, M. L. (2010) · Journal of Applied Physics · doi:10.1063/1.3475151 · Cited by 42
Liquid-Phase Chemical Sensing Using Lateral Mode Resonant Cantilevers
Beardslee, L. A., Demirci, K. S., Luzinova, Y., Mizaikoff, B., Heinrich, S. M., Josse, F., & Brand, O. (2010) · Analytical Chemistry · doi:10.1021/ac1010102 · Cited by 42
Miettinen, T. P., Ly, K. S., Lam, A. R., & Manalis, S. R. (2022) · eLife · doi:10.7554/elife.76664 · Cited by 42
Self-citationMechanical Damping of Longitudinal Acoustic Oscillations of Metal Nanoparticles in Solution
Pelton, M. A., Wang, Y., Gosztola, D. J., & Sader, J. E. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp207971t · Cited by 42
Kalonia, C. K., Kumru, O. S., Kim, J. H., Middaugh, C. R., & Volkin, D. B. (2013) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23738 · Cited by 41
Effects of antibacterial agents and drugs monitored by atomic force microscopy
Longo, G., & Kasas, S. (2014) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1258 · Cited by 41
Direct Cell Mass Measurements Expand the Role of Small Microorganisms in Nature
Khachikyan, A., Milucka, J., Littmann, S., Ahmerkamp, S., Meador, T. B., Könneke, M., Burg, T. P., & Kuypers, M. M. M. (2019) · Applied and Environmental Microbiology · doi:10.1128/aem.00493-19 · Cited by 41
Self-citationMicromechanical observation of the kinetics of biomolecular interactions
Kwon, T., Eom, K., Park, J., Yoon, D. S., Lee, H. L., & Kim, T. S. (2008) · Applied Physics Letters · doi:10.1063/1.3006329 · Cited by 41
Peptide receptor-based selective dinitrotoluene detection using a microcantilever sensor
Hwang, K. S., Lee, M. H., Lee, J., Yeo, W., Lee, J. H., Kim, K.-M., Kang, J. Y., & Kim, T. S. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.09.021 · Cited by 42
Li, S., & Cheng, Z. ‐. (2010) · Journal of Applied Physics · doi:10.1063/1.3431523 · Cited by 40
Photothermal Infrared Spectroscopy of Airborne Samples with Mechanical String Resonators
Yamada, S., Schmid, S., Larsen, T., Hansen, O., & Boisen, A. (2013) · Analytical Chemistry · doi:10.1021/ac402585e · Cited by 40
Extracellular Vesicles: Isolation Methods
Pariset, E., Agache, V., & Millet, A. (2017) · Advanced Biosystems · doi:10.1002/adbi.201700040 · Cited by 44
Growth and division—not a one-way road
Goranov, A. I., & Amon, A. (2010) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2010.06.004 · Cited by 40
Thermoelastic Damping in Hollow and Slotted Microresonators
Prabhakar, S., & Vengallatore, S. (2009) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2009.2016287 · Cited by 40
Resonance behavior of magnetostrictive micro/milli-cantilever and its application as a biosensor
Li, S., Fu, L., Barbaree, J. M., & Cheng, Z. ‐. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.01.038 · Cited by 39
Nanomechanical Sensors as a Tool for Bacteria Detection and Antibiotic Susceptibility Testing
Pujol‐Vila, F., Villa, R., & Álvarez, M. (2020) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2020.00044 · Cited by 40
Nano-Optomechanical Resonators in Microfluidics
Fong, K. Y., Poot, M., & Tang, H. X. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b02388 · Cited by 39
Note: Precision viscosity measurement using suspended microchannel resonators
Lee, I., Park, K., & Lee, J. (2012) · Review of Scientific Instruments · doi:10.1063/1.4768245 · Cited by 39
Shedding Light on Axial Stress Effect on Resonance Frequencies of Nanocantilevers
Pini, V., Tamayo, J., Gil-Santos, E., Ramos, D., Kosaka, P. M., Tong, H. D., van Rijn, C. J. M., & Calleja, M. (2011) · ACS Nano · doi:10.1021/nn200623c · Cited by 39
Characterizing Cellular Biophysical Responses to Stress by Relating Density, Deformability, and Size
Byun, S., Hecht, V. C., & Manalis, S. R. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.08.038 · Cited by 34
Self-citationMicro- and nanodevices integrated with biomolecular probes
Alapan, Y., İçöz, K., & Gurkan, U. A. (2015) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.09.001 · Cited by 40
Integration column: Microfluidic high-throughput screening
Maerkl, S. J. (2008) · Integrative Biology · doi:10.1039/b819762h · Cited by 38
Micro- and nano-structure based oligonucleotide sensors
Ferrier, D. C., Shaver, M. P., & Hands, P. J. W. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.01.031 · Cited by 38
Zhang, W., Yan, H., Jiang, H., Hu, K., Peng, Z., & Meng, G. (2016) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2016.01.029 · Cited by 38
Bouchaala, A. M. S., Nayfeh, A. H., Jaber, N. R., & Younis, M. I. (2016) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/26/10/105009 · Cited by 38
Suspended micro/nano channel resonators: a review
Pastina, A. D., & Villanueva, L. G. (2020) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab6df1 · Cited by 38
Bifurcation-based MEMS mass sensors
Meesala, V. C., Hajj, M. R., & Abdel-Rahman, E. M. (2020) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2020.105705 · Cited by 38
Stockslager, M. A., Malinowski, S. W., Touat, M., Yoon, J. C., Geduldig, J. E., Mirza, M., Kim, A. S., Wen, P. Y., Chow, K.-H., Ligon, K. L., et al. (2021) · Cell Reports · doi:10.1016/j.celrep.2021.109788 · Cited by 36
Self-citationSpectrum of an Oscillator with Jumping Frequency and the Interference of Partial Susceptibilities
Dykman, M. I., Khasin, M., Portman, J., & Shaw, S. W. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.230601 · Cited by 36
Pressurized Fluid Damping of Nanoelectromechanical Systems
Svitelskiy, O. V., Sauer, V. T. K., Liu, N., Cheng, K.-M., Finley, E., Freeman, M. R., & Hiebert, W. K. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.244501 · Cited by 37
Pinto, R. M. R., Brito, P., Chu, V., & Conde, J. P. (2019) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2019.2911666 · Cited by 37
Nanomotion Detection-Based Rapid Antibiotic Susceptibility Testing
Kasas, S., Malovichko, A., Villalba, M. I., Vela, M. E., Yantorno, O. M., & Willaert, R. (2021) · Antibiotics · doi:10.3390/antibiotics10030287 · Cited by 39
Zhao, Y., Lai, H. S. S., Zhang, G., Lee, G., & Li, W. J. (2015) · Biomicrofluidics · doi:10.1063/1.4917290 · Cited by 37
Vibration of Nanoparticles in Viscous Fluids
Chakraborty, D., van Leeuwen, E., Pelton, M. A., & Sader, J. E. (2013) · The Journal of Physical Chemistry C · doi:10.1021/jp401141b · Cited by 37
Review of Recent Developments in Sensing Materials
Venkatanarayanan, A., & Spain, E. (2014) · Elsevier eBooks · doi:10.1016/b978-0-08-096532-1.01303-0 · Cited by 36
Suspended Microchannel Resonators for Ultralow Volume Universal Detection
Son, S., Grover, W. H., Burg, T. P., & Manalis, S. R. (2008) · Analytical Chemistry · doi:10.1021/ac800307a · Cited by 36
Self-citationDevelopment and applications of chip calorimeters as novel biosensors
Lee, W., Lee, & Koh (2012) · Nanobiosensors in Disease Diagnosis · doi:10.2147/ndd.s26438 · Cited by 36
High-ionic-strength pre-concentration via ion concentration polarization for blood-based biofluids
Han, S. I., Yoo, Y. K., Lee, J., Kim, C., Lee, K., Lee, J. H., Kim, H., Yoon, D. S., Hwang, K. S., Kwak, R., et al. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.04.144 · Cited by 38
AFM microfluidic cantilevers as weight sensors for live single cell mass measurements
Chien, C.-C., Jiang, J., Gong, B., Li, T., & Gaitas, A. (2022) · Measurement Science and Technology · doi:10.1088/1361-6501/ac7280 · Cited by 36
Prostate specific antigen detection in patient sera by fluorescence-free BioCD protein array
Wang, X., Zhao, M., Nolte, D. D., & Ratliff, T. L. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.02.009 · Cited by 36
McNaughton, B. H., Agayan, R. R., Clarke, R., Smith, R. G., & Kopelman, R. (2007) · Applied Physics Letters · doi:10.1063/1.2817593 · Cited by 36
High precision particle mass sensing using microchannel resonators in the second vibration mode
Lee, J., Bryan, A. K., & Manalis, S. R. (2011) · Review of Scientific Instruments · doi:10.1063/1.3534825 · Cited by 36
Self-citationUltrahigh-Mass Mass Spectrometry of Single Biomolecules and Bioparticles
Chang, H. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155245 · Cited by 36
Kluková, L., Bertók, T., Kasák, P., & Tkáč, J. (2014) · Analytical Methods · doi:10.1039/c4ay00495g · Cited by 35
Theoretical and experimental investigation of optically driven nanoelectromechanical oscillators
Ilic, B., Krylov, S., & Craighead, H. G. (2010) · Journal of Applied Physics · doi:10.1063/1.3305464 · Cited by 35
Bio-mass sensor using an electrostatically actuated microcantilever in a vacuum microchannel
Aboelkassem, Y., Nayfeh, A. H., & Ghommem, M. (2010) · Microsystem Technologies · doi:10.1007/s00542-010-1087-8 · Cited by 35
A Rapid Unraveling of the Activity and Antibiotic Susceptibility of Mycobacteria
Mustazzolu, A., Venturelli, L., Dinarelli, S., Brown, K., Floto, R. A., Dietler, G., Fattorini, L., Kasas, S., Girasole, M., & Longo, G. (2019) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.02194-18 · Cited by 35
Developments in Transduction, Connectivity and AI/Machine Learning for Point-of-Care Testing
O’Sullivan, S., Ali, Z., Jiang, X., Abdolvand, R., Ünlü, M. S., Silva, H., Baca, J. T., Kim, B. N., Scott, S. M., Sajid, M. I., et al. (2019) · Sensors · doi:10.3390/s19081917 · Cited by 36
Multiscale 3D-printing of microfluidic AFM cantilevers
Kramer, R. C. L. N., Verlinden, E., Angeloni, L., van den Heuvel, A., Fratila-Apachitei, L. E., van der Maarel, S. M., & Ghatkesar, M. K. (2019) · Lab on a Chip · doi:10.1039/c9lc00668k · Cited by 35
A perspective view on the nanomotion detection of living organisms and its features
Venturelli, L., Kohler, A., Stupar, P., Villalba, M. I., Kalauzi, A. J., Radotić, K., Bertacchi, M., Dinarelli, S., Girasole, M., Pešić, M., et al. (2020) · Journal of Molecular Recognition · doi:10.1002/jmr.2849 · Cited by 35
Microfluidics for Environmental Applications
Wang, T., Yu, C., & Xie, X. (2020) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2020_128 · Cited by 35
Direct Detection of Uranyl in Urine by Dissociation from Aptamer-Modified Nanosensor Arrays
Meir, R., Zverzhinetsky, M., Harpak, N., Borberg, E., Burstein, L., Zeiri, O. M., Krivitsky, V., & Patolsky, F. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c02387 · Cited by 37
Fachin, F., Chen, G. D., Toner, M., & Wardle, B. L. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2167669 · Cited by 35
Electrically Addressed Dual Resonator Sensing Platform for Biochemical Detection
Lin, A. T.-H., Yan, J., & Seshia, A. A. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2174420 · Cited by 34
Fu, L., Li, S., Zhang, K., Chen, I., Barbaree, J. M., Zhang, A., & Cheng, Z. ‐. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2095002 · Cited by 34
Goreke, U., Bode, A., Yaman, S., Gurkan, U. A., & Durmus, N. G. (2022) · Lab on a Chip · doi:10.1039/d1lc00686j · Cited by 35
Ripple, D. C., Montgomery, C. B., & Hu, Z. (2014) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24287 · Cited by 34
Li, Y., Wong, I. Y., & Guo, M. (2022) · Small · doi:10.1002/smll.202107305 · Cited by 39
Micromechanical properties of hydrogels measured with MEMS resonant sensors
Corbin, E. A., Millet, L. J., Pikul, J. H., Johnson, C. L., Georgiadis, J. G., King, W. P., & Bashir, R. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9730-z · Cited by 33
Watkins, N. N., Irimia, D., Toner, M., & Bashir, R. (2011) · IEEE Pulse · doi:10.1109/mpul.2011.942762 · Cited by 33
Thermoelastic damping in fluid-conveying microresonators
Zhong, Z.-Y., Zhou, J., Zhang, H.-L., Zhang, W., & Meng, G. (2015) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2015.09.084 · Cited by 33
Bio-Nanotechnology for Active Food Packaging
Sharma, D., & Dhanjal, D. S. (2016) · Journal of Applied Pharmaceutical Science · doi:10.7324/japs.2016.60933 · Cited by 33
Current state of the art in small mass and force metrology within the International System of Units
Shaw, G. A. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaac51 · Cited by 35
Herling, T. W., Müller, T., Rajah, L., Skepper, J. N., Vendruscolo, M., & Knowles, T. P. J. (2013) · Applied Physics Letters · doi:10.1063/1.4803917 · Cited by 33
Zhao, J. X., Zhang, Y., Gao, R., & Liu, S. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.09.033 · Cited by 33
Optical Detection of Single Nanoparticles With a Subwavelength Fiber-Taper
Zhu, J., Ozdemir, Ş. K., & Yang, L. (2011) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2011.2160847 · Cited by 33
Arcamone, J., Sansa, M., Verd, J., Uranga, A., Abadal, G., Barniol, N., van den Boogaart, M. A. F., Brügger, J., & Pérez‐Murano, F. (2008) · Small · doi:10.1002/smll.200800699 · Cited by 33
Microfluidic integration of nanomechanical resonators for protein analysis in serum
Waggoner, P. S., Tan, C. P., & Craighead, H. G. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.08.041 · Cited by 32
Mass sensors with mechanical traps for weighing single cells in different fluids
Weng, Y., Delgado, F. F., Son, S., Burg, T. P., Wasserman, S. C., & Manalis, S. R. (2011) · Lab on a Chip · doi:10.1039/c1lc20736a · Cited by 32
Self-citationAcoustic whispering-gallery modes in optomechanical shells
Bahl, G., Fan, X., & Carmon, T. (2012) · New Journal of Physics · doi:10.1088/1367-2630/14/11/115026 · Cited by 32
Determination of the Density of Protein Particles Using a Suspended Microchannel Resonator
Folzer, E., Khan, T. A., Schmidt, R., Finkler, C., Huwyler, J., Mahler, H., & Koulov, A. V. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24635 · Cited by 32
Next generation microfluidic platforms for high-throughput protein biochemistry
Maerkl, S. J. (2010) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2010.08.010 · Cited by 32
Surface stress sensor using MEMS-based Fabry–Perot interferometer for label-free biosensing
Takahashi, K., Oyama, H., Misawa, N., Okumura, K., Ishida, M., & Sawada, K. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.06.106 · Cited by 32
Nanomechanical identification of liquid reagents in a microfluidic channel
Khan, M. F., Kim, S., Lee, D., Schmid, S., Boisen, A., & Thundat, T. G. (2014) · Lab on a Chip · doi:10.1039/c3lc51273h · Cited by 32
Spectral properties of microcantilevers in viscous fluid
Clark, M., Sader, J. E., Cleveland, J. P., & Paul, M. R. (2010) · Physical Review E · doi:10.1103/physreve.81.046306 · Cited by 31
Liu, S., Höldrich, M., Sievers‐Engler, A., Horak, J., & Lämmerhofer, M. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.02.009 · Cited by 31
Quantification of archaea-driven freshwater nitrification from single cell to ecosystem levels
Klotz, F., Kitzinger, K., Ngugi, D. K., Büsing, P., Littmann, S., Kuypers, M. M. M., Schink, B., & Pester, M. (2022) · The ISME Journal · doi:10.1038/s41396-022-01216-9 · Cited by 32
Cantilever biosensors in drug discovery
Xu, S., & Mutharasan, R. (2009) · Expert Opinion on Drug Discovery · doi:10.1517/17460440903386643 · Cited by 31
Sun, H., Chen, A., & Dalton, L. R. (2009) · IEEE photonics journal · doi:10.1109/jphot.2009.2025602 · Cited by 31
Lu, J. Q., Ikehara, T., Zhang, Y., Mihara, T., Itoh, T., & Maeda, R. (2007) · Japanese Journal of Applied Physics · doi:10.1143/jjap.46.7643 · Cited by 31
Faucher, M., Cordier, Y., Werquin, M., Buchaillot, L., Gaquière, C., & Théron, D. (2012) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2179010 · Cited by 30
Microphotonic Forces from Superfluid Flow
McAuslan, D. L., Harris, G. I., Baker, C. G., Sachkou, Y., He, X., Sheridan, E., & Bowen, W. P. (2016) · Physical Review X · doi:10.1103/physrevx.6.021012 · Cited by 30
Păunescu, D., Mora, C. A., Querci, L., Heckel, R., Puddu, M., Hattendorf, B., Günther, D., & Grass, R. N. (2015) · ACS Nano · doi:10.1021/acsnano.5b04429 · Cited by 30
Diffusion-induced dephasing in nanomechanical resonators
Atalaya, J., Isacsson, A., & Dykman, M. I. (2011) · Physical Review B · doi:10.1103/physrevb.83.045419 · Cited by 30
Metadata
- Authors
- Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R.
- Affiliations
- Massachusetts Institute of Technology (US)
- Innovative Micro Technology (United States) (US)
- Corresponding author
- Manalis, Scott R.
- Venue
- Nature
- Published
- 2007-04
- Volume
- 446
- Issue
- 7139
- Pages
- 1066-1069
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2149562261
- Cited by
- 1,213
- References
- 35
- Citations by year
- 2026: 25 · 2025: 34 · 2024: 39 · 2023: 46 · 2022: 39 · 2021: 58 · 2020: 68 · 2019: 70 · 2018: 75 · 2017: 65 · 2016: 78 · 2015: 78 · 2014: 85 · 2013: 81 · 2012: 84
- FWCI
- 42.64
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion, other-oa)
- TUbilio (Technical University of Darmstadt) (submittedVersion)
- Funders
- National Institutes of Health (5p50gm068762-10)
- National Institute of General Medical Sciences (P50-GM068762)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Acoustic Wave Resonator Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- nanomechanical resonators, suspended microchannel resonators, viscous damping, microfluidic channels, protein adsorption, quality factor, silicon resonators, medical diagnostics, environmental monitoring
- MeSH terms
- Bacteria, Biological Products, Cells, Colloids, Molecular Weight, Proteins, Quartz, Solutions, Vacuum, Microfluidics, Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review