Restoring cortical control of functional movement in a human with quadriplegia
The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.
Abstract
Millions of people worldwide suffer from diseases that lead to paralysis through disruption of signal pathways between the brain and the muscles. Neuroprosthetic devices are designed to restore lost function and could be used to form an electronic 'neural bypass' to circumvent disconnected pathways in the nervous system. It has previously been shown that intracortically recorded signals can be decoded to extract information related to motion, allowing non-human primates and paralysed humans to control computers and robotic arms through imagined movements. In non-human primates, these types of signal have also been used to drive activation of chemically paralysed arm muscles. Here we show that intracortically recorded signals can be linked in real-time to muscle activation to restore movement in a paralysed human. We used a chronically implanted intracortical microelectrode array to record multiunit activity from the motor cortex in a study participant with quadriplegia from cervical spinal cord injury. We applied machine-learning algorithms to decode the neuronal activity and control activation of the participant's forearm muscles through a custom-built high-resolution neuromuscular electrical stimulation system. The system provided isolated finger movements and the participant achieved continuous cortical control of six different wrist and hand motions. Furthermore, he was able to use the system to complete functional tasks relevant to daily living. Clinical assessment showed that, when using the system, his motor impairment improved from the fifth to the sixth cervical (C5-C6) to the seventh cervical to first thoracic (C7-T1) level unilaterally, conferring on him the critical abilities to grasp, manipulate, and release objects. This is the first demonstration to our knowledge of successful control of muscle activation using intracortically recorded signals in a paralysed human. These results have significant implications in advancing neuroprosthetic technology for people worldwide living with the effects of paralysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Prior BCI studies have shown that the motor intention for gross motor skills, such as reaching, grasping or moving a computer cursor, remains neurally encoded in motor cortex after paralysis1–7.”
From High-performance brain-to-text communication via handwriting (2021) · cites this paper as [4]
In the citing paper
“Although the duration of this study was limited to 6 months, UEAs have been successfully implanted in human subjects in numerous studies (25-29) and these devices have continued to work for many years.”
From Visual percepts evoked with an intracortical 96-channel microelectrode array inserted in human occipital cortex (2021) · cites this paper as [27]
In the citing paper
“Additionally, it is apparent from previous work that access to sufficiently large patient populations for concrete and statistically significant conclusions may be difficult to obtain (1–5, 8, 11, 29, 39).”
From Noninvasive neuroimaging enhances continuous neural tracking for robotic device control (2019) · cites this paper as [3]
In the citing paper
“Bouton et al developed an AI system to restore the control of movement in patients with quadriplegia.21”
From Artificial intelligence in healthcare: past, present and future (2017) · cites this paper as [21]
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
Cox, R. W. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0014 · Cited by 10,913
Isolated Hand Paresis: A Case Series
Alstadhaug, K. B., & Sjulstad, A. (2013) · Cerebrovascular Diseases Extra · doi:10.1159/000350708 · Cited by 4,058
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Localization of the motor hand area to a knob on the precentral gyrus. A new landmark
Yousry, T. (1997) · Brain · doi:10.1093/brain/120.1.141 · Cited by 1,837
Mallat, S. (1999) · A Wavelet Tour of Signal Processing · doi:10.1016/b978-012466606-1/50008-8 · Cited by 1,770
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
Research works printed but not linked: 1
- Humber, C., Ito, K. & Bouton, C. Nonsmooth formulation of the support vector machine for a neural decoding problem. arXiv Preprint at http://arxiv.org/abs/1012.0958v1 (2010) · arXiv
Cited by
Items 301–400 of 936
Artificial Intelligence In Healthcare
Rekha, K. P. (2021) · KYAMC Journal · doi:10.3329/kyamcj.v11i4.51989 · Cited by 29
What It Takes to Be a Pioneer: Ability Expectations From Brain-Computer Interface Users
Kögel, J., & Wolbring, G. (2020) · NanoEthics · doi:10.1007/s11569-020-00378-0 · Cited by 28
“The output consists of directing exter-nal devices such as personal computers, wheelchairs or prostheses, or activating a person ’ s muscles [2 – 7].”
BackgroundHosman, T., Hynes, J. B., Saab, J., Wilcoxen, K. G., Buchbinder, B. R., Schmansky, N. J., Cash, S. S., Eskandar, E. N., Simeral, J. D., Franco, B., et al. (2021) · Scientific Reports · doi:10.1038/s41598-020-77616-8 · Cited by 27
Chandrasekaran, S., Bickel, S., Herrero, J. L., Kim, J.-W., Markowitz, N., Espinal, E., Bhagat, N. A., Ramdeo, R., Xu, J., Glasser, M. F., et al. (2021) · Brain stimulation · doi:10.1016/j.brs.2021.07.009 · Cited by 29
“It is well established that motor imagery can be used to identify the hand area of the motor cortex in people with tetraplegia [9].”
BackgroundSelf-citationFrom psychosomatic medicine, brain–computer interface to brain–apparatus communication
Yao, D., Qin, Y. F., & Zhang, Y. (2022) · Brain-Apparatus Communication A Journal of Bacomics · doi:10.1080/27706710.2022.2120775 · Cited by 28
Thøgersen, M. B., Mohammadi, M., Gull, M. A., Bengtson, S. H., Kobbelgaard, F. V., Bentsen, B., Khan, B. Y. A., Severinsen, K. E., Bai, S., Bak, T., et al. (2022) · Sensors · doi:10.3390/s22186919 · Cited by 26
“Lastly, BMIs are particularly important for users who are paralyzed throughout the body as seen in the late stages of ALS.”
BackgroundInfluentialCoste, C., William, L., da Fonseca, L. O., Hiairrassary, A., Andreu, D., Geffrier, A., Teissier, J., Fattal, C., & Guiraud, D. (2022) · Scientific Reports · doi:10.1038/s41598-022-19906-x · Cited by 31
“Surface electrode arrays 20,21 can provide a more flexible and larger set of functional movements but they are clearly limited, in their current form, to a laboratory use as it demands for a day to day calibration under the supervision of a skilled physiotherapist.”
BackgroundGant, K. L., Guerra, S., Zimmerman, L., Parks, B. A., Prins, N. W., & Prasad, A. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aabb13 · Cited by 28
Seu, G. P., Angotzi, G. N., Boi, F., Raffo, L., Berdondini, L., & Meloni, P. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2830659 · Cited by 28
“stimuli with low and controlled latency [13]–[15].”
Thomas, T. M., Candrea, D. N., Fifer, M. S., McMullen, D. P., Anderson, W. S., Thakor, N. V., & Crone, N. E. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2891362 · Cited by 33
“Several groups have primarily used microelectrode arrays (MEAs) to record from single neurons in the sensorimotor cortex of these patients, and to provide users neural control of maneuvering an end-effector in 2D or 3D coordinate space or shaping a prosthetic hand into specific configurations [1]–[6].”
Gastroenterology Meets Machine Learning: Status Quo and Quo Vadis
Adadi, A., Adadi, S., & Berrada, M. (2019) · Advances in Bioinformatics · doi:10.1155/2019/1870975 · Cited by 26
“An illustrative example is a study that proposes a ML-based system capable of reading cortical activity directly from the brain, transmitting signals froma paralyzed human’s motor cortex to hand muscles and restoring motor control [17].”
BackgroundWang, P. T., Camacho, E., Wang, M., Li, Y., Shaw, S. J., Armacost, M., Gong, H., Kramer, D. R., Lee, B., Andersen, R. A., et al. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4b0c · Cited by 27
“For example, such invasive BMIs have enabled accurate brain-control of multi-degree-of-freedom (DOF) robotic arms [1–6] or functional electrical stimulation (FES) devices [7, 8] after stroke or spinal cord injury.”
BackgroundSpeech-related dorsal motor cortex activity does not interfere with iBCI cursor control
Stavisky, S. D., Willett, F. R., Avansino, D. T., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5b72 · Cited by 25
Observing Proton–Electron Mixed Conductivity in Graphdiyne
Li, J., Wang, C., Su, J., Liu, Z., Fan, H., Wang, C., Li, Y., He, Y., Chen, N., Cao, J., et al. (2024) · Advanced Materials · doi:10.1002/adma.202400950 · Cited by 26
Downey, J. E., Schone, H. R., Foldes, S. T., Greenspon, C. M., Liu, F., Verbaarschot, C., Biro, D., Satzer, D. I., Moon, C., Coffman, B. A., et al. (2024) · Human Brain Mapping · doi:10.1002/hbm.70118 · Cited by 27
Lin, X., Zhang, X., Chen, J., & Liu, J. (2025) · Advanced Materials · doi:10.1002/adma.202413938 · Cited by 27
Development of a Polydimethylsiloxane‐Based Electrode Array for Electrocorticography
Lee, K. Y., Moon, H., Kim, B., Kang, Y. N., Jang, J. W., Choe, H. K., & Kim, S. (2020) · Advanced Materials Interfaces · doi:10.1002/admi.202001152 · Cited by 25
Amoruso, E., Dowdall, L., Kollamkulam, M., Ukaegbu, O. C., Kieliba, P., Ng, T., Dempsey‐Jones, H., Clode, D., & Makin, T. R. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac47d9 · Cited by 26
Müller-Putz, G., Kobler, R. J., Pereira, J., Lopes-Dias, C., Hehenberger, L., Mondini, V., Martínez-Cagigal, V., Srisrisawang, N., Pulferer, H. S., Batistić, L., et al. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.841312 · Cited by 28
Bilingual Bidirectional Stretchable Self-Healing Neuristors with Proprioception
Qiu, R., Wang, J., Ren, Q., Huang, W., Zhu, J., Liu, D., Gao, X., Wang, W. “., Liu, Q., & Zhang, M. (2023) · ACS Nano · doi:10.1021/acsnano.3c03212 · Cited by 25
Decoding Speech With Integrated Hybrid Signals Recorded From the Human Ventral Motor Cortex
Ibayashi, K., Kunii, N., Matsuo, T., Ishishita, Y., Shimada, S., Kawai, K., & Saito, N. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00221 · Cited by 26
“…implementation, this electrode has a potential to provide high resolution information through recorded SUAs and may provide online neurofeedback (Bouton et al., 2016; Sitaram et al., 2016) to induce cortical reorganization (Dancause et al., 2005; Murata et al., 2015), which could induce…”
BackgroundImplicit Grasp Force Representation in Human Motor Cortical Recordings
Downey, J. E., Weiss, J. M., Flesher, S. N., Thumser, Z. C., Marasco, P. D., Boninger, M. L., Gaunt, R. A., & Collinger, J. L. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00801 · Cited by 24
“Similarly, for BCIs that aim to restore native limb movement through muscle stimulation, one could modulate stimulation intensity based on intended grasp force (Bouton et al., 2016; Ajiboye et al., 2017).”
Backgroundda Fonseca, L. O., Tigra, W., Navarro, B., Guiraud, D., Fattal, C., Bó, A. P. L., Fachin‐Martins, E., Leynaert, V., Gélis, A., & Coste, C. (2019) · Sensors · doi:10.3390/s19204532 · Cited by 25
“Several non-invasive interfaces have been developed in the past, notably electroencephalography (EEG)-based brain computer interfaces (BCIs).”
BackgroundFeasibility and Safety of Bilateral Hybrid EEG/EOG Brain/Neural–Machine Interaction
Nann, M., Peekhaus, N., Angerhöfer, C., & Soekadar, S. R. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.580105 · Cited by 25
“Due to the fact that the sequence can contain different numbers of subtasks, the balanced accuracy was applied to account for a potential bias toward the more frequent class (Brodersen et al., 2010).”
MethodYao, D., Zhang, Y., Liu, T., Xu, P., Gong, D., Lu, J., Xia, Y., Luo, C., Guo, D., Dong, L., et al. (2020) · Cognitive Neurodynamics · doi:10.1007/s11571-020-09577-7 · Cited by 27
Dohle, E., Swanson, E., Jovanović, L., Yusuf, S., Thompson, L., Horsfall, H. L., Muirhead, W. R., Bashford, L., & Brannigan, J. (2025) · Advanced Science · doi:10.1002/advs.202501912 · Cited by 31
General principles of machine learning for brain-computer interfacing
Iturrate, I., Chavarriaga, R., & Millán, J. D. R. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00023-8 · Cited by 26
Larzabal, C., Auboiroux, V., Karakas, S., Charvet, G., Benabid, A. L., Chabardès, S., Costecalde, T., & Bonnet, S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf291 · Cited by 26
Inflammation neuroscience: neuro‐immune crosstalk and interfaces
Tarnawski, L., & Olofsson, P. S. (2021) · Clinical & Translational Immunology · doi:10.1002/cti2.1352 · Cited by 29
Ji, B., Sun, F., Guo, J., Zhou, Y., You, X., Ye, F., Wang, L., Xu, M., Zeng, W., Liu, J., et al. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00597-x · Cited by 29
“…neural interfacing electrodes serve as the basic research tools for neuroscience 1 – 4 as well as the clinical application tools for the diagnosis and treatment of neurological disorders 5 – 9 , thanks to the functions of electrophysiological recording and/or neural stimulation or modulation.”
MethodPlanar Amorphous Silicon Carbide Microelectrode Arrays for Chronic Recording in Rat Motor Cortex
Abbott, J., Jeakle, E. N., Haghighi, P., Usoro, J. O., Sturgill, B. S., Wu, Y., Geramifard, N., Radhakrishna, R., Patnaik, S. S., Nakajima, S., et al. (2023) · Biomaterials · doi:10.1016/j.biomaterials.2024.122543 · Cited by 25
Emerging Medical Technologies and Their Use in Bionic Repair and Human Augmentation
Manero, A. C., Rivera, V., Fu, Q., Schwartzman, J. D., Gibbs, H. P., Shah, N., Gandhi, D. A., White, E., Crawford, K. E., & Coathup, M. J. (2024) · Bioengineering · doi:10.3390/bioengineering11070695 · Cited by 28
“These arrays have been used for patients with tetraplegia to control highly articulated robotic limbs [36,37], through using functional electrical stimulation of the native limb to perform functional reach-and-grasp tasks [37,38], or to provide sensations of touch through intracortical…”
MethodBrandman, D. M., Burkhart, M. C., Kelemen, J. N., Franco, B., Harrison, M. T., & Hochberg, L. R. (2018) · Neural Computation · doi:10.1162/neco_a_01129 · Cited by 24
“However, the experience of multiple iBCI groups (Jarosiewicz et al., 2015; Collinger et al., 2013; Bouton et al., 2016) suggests that decoder performance may change dramatically from day to day.”
BackgroundSombeck, J. T., & Miller, L. E. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5cf3 · Cited by 25
Classification of Individual Finger Movements Using Intracortical Recordings in Human Motor Cortex
Jorge, A., Royston, D., Tyler‐Kabara, E. C., Boninger, M. L., & Collinger, J. L. (2020) · Neurosurgery · doi:10.1093/neuros/nyaa026 · Cited by 26
Neuroprosthetics for Human Performance Optimization
Chang, Y.-J., Krishna, G., & Fernandez, B. R. (2019) · Oxford University Press eBooks · doi:10.1093/oso/9780190455132.003.0008 · Cited by 23
Pre-movement sensorimotor oscillations shape the sense of agency by gating cortical connectivity
Bertoni, T., Noel, J., Bockbrader, M. A., Foglia, C., Colachis, S. C., Orset, B., Evans, N. J., Herbelin, B., Rezai, A. R., Panzeri, S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-58683-9 · Cited by 26
“Please explain also in the text.”
InfluentialSelf-citationBrain-Computer Interface, Neuromodulation, and Neurorehabilitation Strategies for Spinal Cord Injury
Cajigas, I., & Vedantam, A. (2021) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2021.03.012 · Cited by 27
Stability of motor representations after paralysis
Guan, C., Aflalo, T., Zhang, C. Y., Amoruso, E., Rosario, E. R., Pouratian, N., & Andersen, R. A. (2022) · eLife · doi:10.7554/elife.74478 · Cited by 25
Challenges of neural interfaces for stroke motor rehabilitation
Vidaurre, C., Irastorza-Landa, N., Sarasola-Sanz, A., Insausti-Delgado, A., Ray, A. M., Bibián, C., Helmhold, F., Mahmoud, W. J., Ortego-Isasa, I., López‐Larraz, E., et al. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1070404 · Cited by 32
IoT-driven augmented reality and virtual reality systems in neurological sciences
Sahu, M., Gupta, R. V., Ambasta, R. K., & Kumar, P. (2024) · Internet of Things · doi:10.1016/j.iot.2024.101098 · Cited by 27
Qian, L., Jin, F., Li, T., Wei, Z., Ma, X., Zheng, W., Javanmardi, N., Wang, Z., Ma, J., Lai, C., et al. (2024) · Advanced Materials · doi:10.1002/adma.202406636 · Cited by 24
Decoding of muscle activity from the sensorimotor cortex in freely behaving monkeys
Umeda, T., Koizumi, M., Katakai, Y., Saito, R., & Seki, K. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.04.045 · Cited by 28
Viral-Mediated Optogenetic Stimulation of Peripheral Motor Nerves in Non-human Primates
Williams, J. J., Watson, A. M., Vazquez, A. L., & Schwartz, A. B. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00759 · Cited by 26
The Neural Representation of Force across Grasp Types in Motor Cortex of Humans with Tetraplegia
Rastogi, A., Willett, F. R., Abreu, J., Crowder, D. C., Murphy, B. A., Memberg, W. D., Vargas-Irwin, C. E., Miller, J. P., Sweet, J. A., Walter, B. L., et al. (2021) · eNeuro · doi:10.1523/eneuro.0231-20.2020 · Cited by 23
Invasive Brain-Computer Interfaces and Neural Recordings From Humans
Klaes, C. (2018) · Handbook of behavioral neuroscience · doi:10.1016/b978-0-12-812028-6.00028-8 · Cited by 26
Lifetime engineering of bioelectronic implants with mechanically reliable thin film encapsulations
Niemiec, M., & Kim, K. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad0b19 · Cited by 32
Young, D. R., Willett, F. R., Memberg, W. D., Murphy, B., Rezaii, P. G., Walter, B. L., Sweet, J., Miller, J. P., Shenoy, K. V., Hochberg, L. R., et al. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf606 · Cited by 25
“Brain–computer interfaces (BCIs) decode recorded neural activity into command signals for external effectors, such as virtual cursors [1–4], robotic arms [1, 5–8], or functional electrical stimulation (FES) systems [9, 10].”
BackgroundSingle-paradigm and hybrid brain computing interfaces and their use by disabled patients
de Neeling, M. G. J., & Hulle, M. M. V. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab2706 · Cited by 23
“Motor BCIs detecting limb movement intention have also been actively used in stroke rehabilitation (Frisoli et al 2012, Ortner et al 2012, Roset et al 2013, Frolov et al 2017, Guger et al 2017a; for recent reviews, see Cervera et al (2018) and López-Larraz et al (2018)).”
BackgroundMethodInfluentialYao, Z., Hessburg, J. P., Kumar, J. N. A., & Francis, J. T. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00579 · Cited by 24
“BMIs have been used to restore reaching and grasping for paralyzed patients with some success (Bouton et al., 2016; Collinger et al., 2013; Hochberg et al., 2012), and making such systems more robust and easier to control is of great importance.”
MethodBurkhart, M. C., Brandman, D. M., Franco, B., Hochberg, L. R., & Harrison, M. T. (2020) · Neural Computation · doi:10.1162/neco_a_01275 · Cited by 23
“…et al., 2015; Jarosiewicz et al., 2015; Nuyujukian et al., 2018), robotic arms (Hochberg et al., 2012; Collinger et al., 2013), and functional electrical stimulation systems (Bouton et al., 2016; Ajiboye et al., 2017) with the real-time decoded neural activity generated during attempted movement.”
BackgroundState-Based Decoding of Force Signals From Multi-Channel Local Field Potentials
Ahmadi, A., Khorasani, A., Shalchyan, V., & Daliri, M. R. (2020) · IEEE Access · doi:10.1109/access.2020.3019267 · Cited by 22
“…trajectories of limb position or velocity are directly decoded from the intracortical signals and converted to a command signal to The associate editor coordinating the review of this manuscript and approving it for publication was Derek Abbott . control an external device or prosthetic limbs [17].”
BackgroundIntelligent biohybrid systems for functional brain repair
Panuccio, G., Semprini, M., & Chiappalone, M. (2016) · European Journal of Molecular & Clinical Medicine · doi:10.1016/j.nhtm.2016.10.001 · Cited by 25
Hersh, A. M., Weber-Levine, C., Jiang, K., & Theodore, N. (2023) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2023.10.001 · Cited by 23
Neural interfaces take another step forward
Jackson, A. (2016) · Nature · doi:10.1038/539177a · Cited by 21
Giuliano Vanghetti and the innovation of “cineplastic operations”
Tropea, P., Mazzoni, A., Micera, S., & Corbo, M. (2017) · Neurology · doi:10.1212/wnl.0000000000004488 · Cited by 23
“Moreover, recent studies show that it is possible to extend Vanghetti’s principle in patients with tetraplegia, using the residual functionality of the motor cortex to control the remaining ability of the arm muscles, bypassing spinal lesions.(26,27) From a neurologic perspective, most brain motor programs for sensori…”
BackgroundDesign and testing of a 96-channel neural interface module for the Networked Neuroprosthesis system
Bullard, A. J., Nason, S. R., Irwin, Z. T., Nu, C. S., Smith, B., Campean, A., Peckham, P. H., Kilgore, K. L., Willsey, M. S., Patil, P. G., et al. (2019) · Bioelectronic Medicine · doi:10.1186/s42234-019-0019-x · Cited by 24
Decoding neural activity to predict rat locomotion using intracortical and epidural arrays
Barroso, F. O., Yoder, B., Tentler, D. P., Wallner, J. J., Kinkhabwala, A. A., Jantz, M., Flint, R. D., Tostado-Marcos, P., Pei, E., Satish, A. D. R., et al. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab0698 · Cited by 21
“Prior to surgery, rats were acclimated to a motorized treadmill (Columbus Instruments, Columbus, OH) and trained for J. Neural Eng. 16 (2019) 036005”
MethodKong, D., Wang, W., Guo, D., & Shi, Y. (2022) · Applied Sciences · doi:10.3390/app12104993 · Cited by 21
Nanoelectronics for Minimally Invasive Cellular Recordings
Pei, F., & Tian, B. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201906210 · Cited by 22
Valtierra, J. L., Delgado‐Restituto, M., Fiorelli, R., & Rodriguez-Vazquez, A. (2020) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2020.2968087 · Cited by 22
Alawieh, H., Liu, D. H., Madera, J., Kumar, S., Rácz, F. S., Fey, A. M., & Millán, J. D. R. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2418920122 · Cited by 22
Friedenberg, D. A., Bouton, C. E., Annetta, N. V., Skomrock, N. D., Zhang, M., Schwemmer, M. A., Bockbrader, M. A., Mysiw, W. J., Rezai, A. R., Bresler, H. S., et al. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591381 · Cited by 21
“More details of the experimental setup can be found in [8].”
BackgroundMethodInfluentialSelf-citationBrain-Computer Interfaces in Quadriplegic Patients
Lee, M. B., Kramer, D. R., Peng, T. D., Barbaro, M. F., Liu, C. Y., Kellis, S., & Lee, B. (2019) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2018.12.009 · Cited by 21
McMullen, D. P., Thomas, T. M., Fifer, M. S., Candrea, D. N., Tenore, F. V., Nickl, R. W., Pohlmeyer, E. A., Coogan, C. G., Osborn, L. E., Schiavi, A. J., et al. (2021) · Journal of neurosurgery · doi:10.3171/2020.9.jns202675 · Cited by 23
Variation of Finger Activation Patterns Post-stroke Through Non-invasive Nerve Stimulation
Shin, H., Zheng, Y., & Hu, X. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.01101 · Cited by 20
“Advances in NMES techniques to alleviate these issues involve various multielectrode techniques, which can stimulate multiple small regions of the muscle to help distribute the current and potentially activate more muscle fibers (14, 15).”
BackgroundThe Pursuit of Chronically Reliable Neural Interfaces: A Materials Perspective
Guo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00599 · Cited by 19
“Although the science fiction has come closer to reality with the demonstration of possibility in humans (Hochberg et al., 2012; Collinger et al., 2013; Bouton et al., 2016), a feasible system for long-term daily use is still far out of reach, primarily due to the discovery of fibrotic encapsulation developing around t…”
BackgroundBavishi, S., Rosenthal, J., & Bockbrader, M. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-54456-6.00017-7 · Cited by 21
Self-citationTubig, P. A., & Gilbert, F. (2023) · Advances in neuroethics · doi:10.1007/978-3-031-26801-4_3 · Cited by 25
Nagwade, P., Parandeh, S., & Lee, S. (2023) · Soft Science · doi:10.20517/ss.2023.12 · Cited by 21
A review of ethical considerations for the medical applications of brain-computer interfaces
Zhang, Z., Chen, Y., Zhao, X., Fan, W., Peng, D., Li, T., Zhao, L., & Fu, Y. (2024) · Cognitive Neurodynamics · doi:10.1007/s11571-024-10144-7 · Cited by 23
“Due to the limitations inherent in conventional user interfaces, BCIs are particularly aimed at providing compensatory solutions for motor impairments in patients with complete motor SCI, particularly those with high-level injuries and quadriplegia (Bouton et al. 2016 ).”
Saniotis, A., Henneberg, M., & Sawalma, A. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00153 · Cited by 19
“Brain-machine interfaces (BCI) have been successful in generating physical movement from brain signals which with training enables navigating a computerized wheelchair (Bouton et al., 2016; Rajangam et al., 2016; Sharma et al., 2016).”
BackgroundCorrelation of mRNA Expression and Signal Variability in Chronic Intracortical Electrodes
Falcone, J., Carroll, S. L., Saxena, T. K., Mandavia, D., Clark, A., Yarabarla, V., & Bellamkonda, R. V. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00026 · Cited by 20
“Signal loss in both clinical (Simeral et al., 2011; Collinger et al., 2013; Perge et al., 2014; Bouton et al., 2016; Downey et al., 2016; Ajiboye et al., 2017) and preclinical (Karumbaiah et al.”
BackgroundKhorasani, A., Shalchyan, V., & Daliri, M. R. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00350 · Cited by 19
Closed-Loop Systems and In Vitro Neuronal Cultures: Overview and Applications
Bisio, M., Pimashkin, A. S., Buccelli, S., Tessadori, J., Semprini, M., Levi, T., Colombi, I., Gladkov, A., Mukhina, I. V., Averna, A., et al. (2019) · Advances in neurobiology · doi:10.1007/978-3-030-11135-9_15 · Cited by 20
Sun, M., Smith, C., Howard, D., Kenney, L. P. J., Luckie, H., Waring, K., Taylor, P. N., Merson, E., & Finn, S. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00449 · Cited by 19
Hu, K., Jamali, M., Moses, Z. B., Ortega, C. A., Friedman, G. N., Xu, W., & Williams, Z. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-28940-7 · Cited by 23
Ahmed, B., Khan, S., Lim, H., & Ku, J. H. (2025) · Electronics · doi:10.3390/electronics14030491 · Cited by 23
Shaeri, M., & Sodagar, A. M. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2022.3151340 · Cited by 23
“In addition to the three aforementioned applications, mathematical transformations ( e.g. , wavelets) are employed for feature extraction in neural decoding [118], [119], data visualization [9], and also for the extraction of analog signals [43].”
BackgroundAhmadi, N., Adiono, T., Purwarianti, A., Constandinou, T. G., & Bouganis, C.-S. (2022) · IEEE Access · doi:10.1109/access.2022.3159225 · Cited by 19
“Brain-machine interfaces (BMIs) seek to restore lost motor function in severely paralysed patients by translating brain activity into control signals for guiding assistive devices, such as a computer cursor [1]–[4], robotic arm [5]–[7], or functional electrical stimulation (FES) system [8]–[10].”
BackgroundInsausti-Delgado, A., López‐Larraz, E., Nishimura, Y., Ziemann, U., & Ramos‐Murguialday, A. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.975037 · Cited by 24
“stability, allowing closed-loop neurostimulation (Bouton et al., 2016; Ajiboye et al., 2017).”
Cajigas, I., Davis, K., Prins, N. W., Gallo, S., Naeem, J., Fisher, L., Ivan, M. E., Prasad, A., & Jagid, J. R. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.1077416 · Cited by 21
“, 2018), and spinal cord injury (SCI; Bouton et al., 2016), among others.”
BackgroundInterfacing Neuron-Motor Pathways with Stretchable and Biocompatible Electrode Arrays
Jiang, Z., Zhu, M. J., & Chen, X. (2024) · Accounts of Chemical Research · doi:10.1021/acs.accounts.4c00215 · Cited by 18
Artificial intelligence in dermatology
Rundle, C. W., Hollingsworth, P., & Dellavalle, R. P. (2021) · Clinics in Dermatology · doi:10.1016/j.clindermatol.2021.03.011 · Cited by 20
Srisrisawang, N., & Müller-Putz, G. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.830221 · Cited by 20
2D MXene interfaces preserve the basal electrophysiology of targeted neural circuits
Xiao, M., Li, X., Pifferi, S., Pastore, B., Liu, Y., Lazzarino, M., Torre, V., Yang, X., Menini, A., & Tang, M. (2022) · Nanoscale · doi:10.1039/d2nr01542k · Cited by 18
Principled Approaches to Direct Brain Stimulation for Cognitive Enhancement
Sreekumar, V., Wittig, J. H., Sheehan, T. C., & Zaghloul, K. A. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00650 · Cited by 18
“INTRODUCTION Major advances have been made recently in the use of intracortical brain-computer interfaces (iBCI) to restore movements in patients with disorders such as tetraplegia (Bouton et al., 2016; Ajiboye et al., 2017).”
Debnath, S., Prins, N. W., Pohlmeyer, E. A., Mylavarapu, R. V., Geng, S., Sanchez, J. C., & Prasad, A. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aada67 · Cited by 19
Bouton, C. E. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00022-6 · Cited by 21
Self-citationMind-Controlled Optical Manipulation
Peng, L., Yao, J., Bai, Y., Sun, Y., Zeng, J., Ren, Y., Xie, J., Hu, Z., Zhang, Q., & Yang, Y. (2024) · ACS Photonics · doi:10.1021/acsphotonics.3c01732 · Cited by 18
Bioelectronic medicine: an unexpected path to new therapies
Olofsson, P. S., & Bouton, C. E. (2019) · Journal of Internal Medicine · doi:10.1111/joim.12967 · Cited by 20
Self-citationFatima, N., Shuaib, A. M., & Saqqur, M. (2020) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2020.106069 · Cited by 18
Feng, H., Zhao, Y., Yan, W., Wei, X., Lin, J.-P., Jiang, P., Wang, C., & Li, B. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.843749 · Cited by 20
“Machine learning, an artificial intelligence method, utilizes complex algorithms in analyzing large-scale and heterogeneous data sets to extract useful patterns (17, 18).”
MethodApplying the IEEE BRAIN neuroethics framework to intra-cortical brain-computer interfaces
Soldado-Magraner, J., Antonietti, A., French, J., Higgins, N., Young, M. J., Larrivee, D., & Monteleone, R. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad3852 · Cited by 16
“Another recent development has been the incorporation of artificial stimulation of the brain and body parts driven by motor signals recorded intra-cortically [1, 8, 28].”
Intracortical brain-computer interfaces in primates: a review and outlook
Rouzitalab, A., Boulay, C., Park, J., & Sachs, A. J. (2023) · Biomedical Engineering Letters · doi:10.1007/s13534-023-00286-8 · Cited by 16
The role of distinct ECoG frequency features in decoding finger movement
Merino, E. C., Faes, A., & Hulle, M. M. V. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad0c5e · Cited by 20
“This has been successfully demonstrated in patients controlling a paralysed upper limb through neuromuscular stimulation [2, 3], a prosthetic limb [4, 5] an exoskeleton [6], or having their imagined handwriting movements translated into text [7].”
5-year follow-up of a fully implanted brain–computer interface in a spinal cord injury patient
Davis, K., Wyse‐Sookoo, K., Raza, F., Meschede-Krasa, B., Prins, N. W., Fisher, L., Brown, E. N., Cajigas, I., Ivan, M. E., Jagid, J. R., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adc48c · Cited by 20
“Various studies have successfully used implantable Utah micro-electrode arrays (MEAs) (Blackrock Microsystems, UT) in clinical trials involving several individuals with SCI [20, 21, 31–38].”
Electronic Dura Mater Meddling in the Central Nervous System
Bloch, J., Lacour, S. P., & Courtine, G. (2017) · JAMA Neurology · doi:10.1001/jamaneurol.2016.5767 · Cited by 19
Clinical therapeutic guideline for neurorestoration in spinal cord injury (Chinese version 2016)
Feng, Y., Sun, T., Chen, L., Xie, J., Zhang, Z., Huang, H., & He, X. (2017) · Journal of Neurorestoratology · doi:10.2147/jn.s119581 · Cited by 16
“56”
Fukuma, R., Yanagisawa, T., Yokoi, H., Hirata, M., Yoshimine, T., Saitoh, Y., Kamitani, Y., & Kishima, H. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00478 · Cited by 16
“Brain–machine interfaces (BMIs) can reconstructmotor function in paralyzed subjects (Hochberg et al., 2006, 2012; Yanagisawa et al., 2012a; Collinger et al., 2013; Bouton et al., 2016) as well as induce functional alterations in cortical activity (Ganguly et al.”
Background
Metadata
- Authors
- Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., Morgan, A. G., Deogaonkar, M., & Rezai, A. R.
- Affiliations
- Battelle (US)
- The Ohio State University (US)
- Corresponding author
- Bouton, Chad E.
- Sharma, Gaurav
- ORCID
- Venue
- Nature
- Published
- 2016-04-13
- Volume
- 533
- Issue
- 7602
- Pages
- 247-250
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2341256599
- Cited by
- 924
- References
- 32
- Citations by year
- 2026: 49 · 2025: 72 · 2024: 75 · 2023: 87 · 2022: 96 · 2021: 118 · 2020: 112 · 2019: 91 · 2018: 106 · 2017: 69 · 2016: 47
- FWCI
- 58.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- Battelle
- Ohio State University
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- tetraplegia, cervical spinal cord injury, intracortical microelectrode arrays, neuromuscular electrical stimulation, neural prostheses, forearm muscle activation, finger movement, multi-unit activity, real-time neural decoding, upper limb paralysis, activities of daily living
- MeSH terms
- Machine Learning, Activities of Daily Living, Algorithms, Electric Stimulation, Electrodes, Implanted, Forearm, Hand, Humans, Imagination, Magnetic Resonance Imaging, Male, Microelectrodes, Motor Cortex, Movement, Quadriplegia, Spinal Cord Injuries, Muscle, Skeletal, Hand Strength, Young Adult, Cervical Cord
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.