The Pursuit of Chronically Reliable Neural Interfaces: A Materials Perspective
Open accessAbstract
Brain-computer interfaces represent one of the most astonishing technologies in our era. However, the grand challenge of chronic instability and limited throughput of the electrode-tissue interface has significantly hindered the further development and ultimate deployment of such exciting technologies. A multidisciplinary research workforce has been called upon to respond to this engineering need. In this paper, I briefly review this multidisciplinary pursuit of chronically reliable neural interfaces from a materials perspective by analyzing the problem, abstracting the engineering principles, and summarizing the corresponding engineering strategies. I further draw my future perspectives by extending the proposed engineering principles.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Implant materials are assessed based on their chemical and mechanical similarity to the target tissue to prevent an undesirable immune response.
“These materials will also be assessed based on their chemical and mechanical similarity to the target tissue to prevent an undesirable immune response to these alien materials (Guo 2016).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Guo 2016
For some electrode coatings, particularly conducting polymers, there is an additional technological challenge of delamination of films from underlying conductors.
“However, for some of these coatings, in particular conducting polymers, there is an additional technological challenge of delamination of these films from the underlying conductors (Guo 2016).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Guo 2016
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · see citing works
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · see citing works
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · see citing works
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721 · see citing works
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599 · see citing works
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · see citing works
Bio-Inspired Polymer Composite Actuator and Generator Driven by Water Gradients
Ma, M., Guo, L., Anderson, D. G., & Langer, R. (2013) · Science · doi:10.1126/science.1230262 · Cited by 851 · see citing works
Self-citationKozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721 · see citing works
Conducting polymers for neural interfaces: Challenges in developing an effective long-term implant
Green, R. A., Lovell, N. H., Wallace, G. G., & Poole-Warren, L. A. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.047 · Cited by 691 · see citing works
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646 · see citing works
Macroporous Nanowire Nanoelectronic Scaffolds for Synthetic Tissues
Jia Liu, B., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., Lieber, C. M., & Tian, B. (2012) · Digital Access to Scholarship at Harvard (DASH) (Harvard University) · Cited by 642 · see citing works
Zhang, A., & Lieber, C. M. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 629 · see citing works
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622 · see citing works
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504 · see citing works
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488 · see citing works
Electrochemically controlled drug delivery based on intrinsically conducting polymers
Svirskis, D. M., Travaš‐Sejdić, J., Rodgers, A., & Garg, S. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.03.023 · Cited by 440 · see citing works
Applications of conducting polymers and their issues in biomedical engineering
Ravichandran, R., Sundarrajan, S., Venugopal, J. R., Mukherjee, S., & Ramakrishna, S. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0120.focus · Cited by 431 · see citing works
Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
Xie, C., Liu, J., Fu, T.-M., Dai, X., Zhou, W., & Lieber, C. M. (2015) · Nature Materials · doi:10.1038/nmat4427 · Cited by 404 · see citing works
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384 · see citing works
Large-scale, high-density (up to 512 channels) recording of local circuits in behaving animals
Berényi, A., Somogyvári, Z., Nagy, A. J., Roux, L., Long, J. D., Fujisawa, S., Stark, E., Leonardo, A. M., Harris, T. D., & Buzsáki, G. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00785.2013 · Cited by 299 · see citing works
Mechanically-compliant intracortical implants reduce the neuroinflammatory response
Nguyen, J. K., Park, D. J., Skousen, J. L., Hess-Dunning, A. E., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056014 · Cited by 274 · see citing works
Flexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
Lacour, S. P., Benmerah, S., Tarte, E. J., FitzGerald, J. J., Serra, J., McMahon, S. B., Fawcett, J. W., Graudejus, O., Yu, Z., & Morrison, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0644-8 · Cited by 265 · see citing works
Biomimetic conducting polymer-based tissue scaffolds
Hardy, J. G., Lee, J. Y., & Schmidt, C. E. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.03.011 · Cited by 253 · see citing works
Potter, K. A., Buck, A. C., Self, W. K., & Capadona, J. R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046020 · Cited by 239 · see citing works
Kozai, T. D. Y., Vazquez, A. L., Weaver, C. L., Kim, S.-G., & Cui, X. T. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066001 · Cited by 215 · see citing works
Kozai, T. D. Y., Catt, K. A., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 214 · see citing works
Implantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202 · see citing works
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175 · see citing works
Biocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160 · see citing works
Brain activity mapping at multiple scales with silicon microprobes containing 1,024 electrodes
Shobe, J. L., Claar, L. D., Parhami, S., Bakhurin, K. I., & Masmanidis, S. C. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00464.2015 · Cited by 146 · see citing works
Kozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136 · see citing works
Stretchable Polymeric Multielectrode Array for Conformal Neural Interfacing
Guo, L., Ma, M., Zhang, N., Langer, R., & Anderson, D. G. (2014) · Advanced Materials · doi:10.1002/adma.201304140 · Cited by 128 · see citing works
Self-citationBiosynthetic Polymers for Medical Applications
(2016) · Elsevier eBooks · doi:10.1016/c2013-0-16462-8 · Cited by 87 · see citing works
Conducting polymers and their biomedical applications
Yi, N., & Abidian, M. R. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-105-4.00010-9 · Cited by 82 · see citing works
Martin, D. C. (2015) · MRS Communications · doi:10.1557/mrc.2015.17 · Cited by 77 · see citing works
Chronic multichannel neural recordings from soft regenerative microchannel electrodes during gait
Musick, K. M., Rigosa, J., Narasimhan, S., Wurth, S., Capogrosso, M., Chew, D. J., Fawcett, J. W., Micera, S., & Lacour, S. P. (2015) · Scientific Reports · doi:10.1038/srep14363 · Cited by 70 · see citing works
Regenerative Electrode Interfaces for Neural Prostheses.
Thompson, C. H., Zoratti, M. J., Langhals, N. B., & Purcell, E. K. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0279 · Cited by 67 · cited 4× · see citing works
“…neural interfaces is being revived, combining state-of-the-art stretchable electronics with tissue engineering approaches for a better-integrated electrode-tissue interface (Figure 1D; Lacour et al., 2010; Clements et al., 2013; Musick et al., 2015; Srinivasan et al., 2015; Thompson et al., 2016).”
BackgroundInfluentialMicrochannel-based regenerative scaffold for chronic peripheral nerve interfacing in amputees
Srinivasan, A., Tahilramani, M., Bentley, J. T., Gore, R. K., Millard, D. C., Mukhatyar, V. J., Joseph, A., Haque, A. S., Stanley, G. B., English, A. W., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.11.035 · Cited by 67 · see citing works
Schalk, G. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/p01 · Cited by 62 · see citing works
New approaches for CMOS-based devices for large-scale neural recording
Ruther, P., & Paul, O. (2014) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2014.10.007 · Cited by 61 · see citing works
Kolarcik, C. L., Bourbeau, D., Azemi, E., Rost, E., Zhang, L., Lagenaur, C. F., Weber, D. J., & Cui, X. T. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.034 · Cited by 59 · see citing works
Shen, W., Karumbaiah, L., Liu, X., Saxena, T. K., Chen, S., Patkar, R., Bellamkonda, R. V., & Allen, M. G. (2015) · Microsystems & Nanoengineering · doi:10.1038/micronano.2015.10 · Cited by 57 · see citing works
Regenerative Scaffold Electrodes for Peripheral Nerve Interfacing
Clements, I. P., Mukhatyar, V. J., Srinivasan, A., Bentley, J. T., Andreasen, D. S., & Bellamkonda, R. V. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2217352 · Cited by 46 · see citing works
A review of Microelectrode Array technologies: Design and implementation challenges
Ghane-Motlagh, B., & Sawan, M. (2013) · International Conference on Advances in Biomedical Engineering (ICABME) · doi:10.1109/icabme.2013.6648841 · Cited by 28 · see citing works
Extracellular matrix-based materials for neural interfacing
Chen, S., & Allen, M. G. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.120 · Cited by 22 · see citing works
Macroporous nanowire nanoelectronic scaffolds for synthetic tissues
Tian, B., Liu, J., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., & Lieber, C. M. (2012) · Nature Materials · doi:10.1038/nmat3404 · Cited by 20 · see citing works
Toward a Convergence of Regenerative Medicine, Rehabilitation, and Neuroprosthetics
Aravamudhan, S., & Bellamkonda, R. V. (2011) · Journal of Neurotrauma · doi:10.1089/neu.2010.1542 · Cited by 17 · see citing works
CHAPTER 9. Conducting Polymers as Smart Materials for Tissue Engineering
Guo, L. (2016) · RSC smart materials · doi:10.1039/9781782626756-00239 · Cited by 5 · see citing works
Self-citationIntegrated Microelectrode Arrays
Heer, F., & Hierlemann, A. (2007) · Integrated circuits and systems · doi:10.1007/978-0-387-68913-5_8 · Cited by 2 · see citing works
Complete regenerative peripheral nerve interfaces, fatigue and recovery
French, Z. P., Mays, E. A., Hassett, C. A., Moon, J. D., Langhals, N. B., Cederna, P. S., & Urbanchek, M. G. (2014) · IEEE Signal Processing in Medicine and Biology Symposium · doi:10.1109/spmb.2014.7002970 · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Peripheral nerve bionic interface: a review of electrodes
Russell, C., Roche, A. D., & Chakrabarty, S. (2019) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-019-00086-3 · Cited by 67 · see citing works
Biotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11 · see citing works
- Authors
- Guo, L.
- Affiliations
- The Ohio State University (US)
- Corresponding author
- Guo, Liang
- ORCID
- Guo, Liang
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2016-12-27
- Volume
- 10
- Pages
- 599-599
- ISSN
- 1662-453X (ISSN-L)
- PMC
- PMC5186773
- OpenAlex
- W2561617906
- Cited by
- 19
- References
- 51
- Citations by year
- 2026: 2 · 2025: 2 · 2022: 1 · 2021: 1 · 2020: 3 · 2019: 4 · 2018: 4 · 2017: 2
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Frontiers in Neuroscience (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Ohio State University
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- brain-computer interface, neural interfaces, electrode materials, chronic instability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review