The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity
Open accessAbstract
High-fidelity intracranial electrode arrays for recording and stimulating brain activity have facilitated major advances in the treatment of neurological conditions over the past decade. Traditional arrays require direct implantation into the brain via open craniotomy, which can lead to inflammatory tissue responses, necessitating development of minimally invasive approaches that avoid brain trauma. Here we demonstrate the feasibility of chronically recording brain activity from within a vein using a passive stent-electrode recording array (stentrode). We achieved implantation into a superficial cortical vein overlying the motor cortex via catheter angiography and demonstrate neural recordings in freely moving sheep for up to 190 d. Spectral content and bandwidth of vascular electrocorticography were comparable to those of recordings from epidural surface arrays. Venous internal lumen patency was maintained for the duration of implantation. Stentrodes may have wide ranging applications as a neural interface for treatment of a range of neurological conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, Q., Wang, C., Zheng, M., Li, Y., Li, J., Zhang, L., Shang, X., & Yan, C. (2015) · Cerebrovascular Diseases · doi:10.1159/000369778 · Cited by 11,533
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323
3D Slicer as an image computing platform for the Quantitative Imaging Network
Fedorov, A., Beichel, R., Kalpathy-Cramer, J., Finet, J., Fillion-Robin, J.-C., Pujol, S., Bauer, C., Jennings, D., Fennessy, F., Sonka, M., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.05.001 · Cited by 9,023
A Randomized Trial of Intraarterial Treatment for Acute Ischemic Stroke
Berkhemer, O. A., Fransen, P. S. S., Beumer, D., van den Berg, L. A., Lingsma, H. F., Yoo, A. J., Schonewille, W. J., Vos, J. A., Nederkoorn, P. J., Wermer, M. J. H., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1411587 · Cited by 6,657
Cortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147
Endovascular Therapy for Ischemic Stroke with Perfusion-Imaging Selection
Campbell, B. C. V., Mitchell, P. J., Kleinig, T. J., Dewey, H. M., Churilov, L., Yassi, N., Yan, B., Dowling, R. J., Parsons, M. W., Oxley, T. J., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1414792 · Cited by 5,819
Self-citationSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
A Randomized Trial of Deep-Brain Stimulation for Parkinson's Disease
Deuschl, G., Schade-Brittinger, C., Krack, P., Volkmann, J., Schäfer, H., Bötzel, K., Daniels, C., Deutschländer, A., Dillmann, U., Eisner, W., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa060281 · Cited by 2,944
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Treatment Strategies for Acute Ischemic Stroke Caused by Carotid Artery Occlusion
Li, W., Yin, Q., Xu, G., & Liu, X. (2016) · Interventional Neurology · doi:10.1159/000445304 · Cited by 2,319
Sveinsson, O., Herrman, L., & Holmin, S. (2016) · Case Reports in Neurology · doi:10.1159/000452213 · Cited by 2,034
Stenting versus Aggressive Medical Therapy for Intracranial Arterial Stenosis
Chimowitz, M. I., Lynn, M. J., Derdeyn, C. P., Turan, T. N., Fiorella, D., Lane, B. F., Janis, L. S., Lutsep, H. L., Barnwell, S. L., Waters, M. F., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1105335 · Cited by 1,901
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
A Primer for EEG Signal Processing in Anesthesia
Rampil, I. J. (1998) · Anesthesiology · doi:10.1097/00000542-199810000-00023 · Cited by 1,503
Mirowski, M., Reid, P. R., Mower, M. M., Watkins, L., Gott, V. L., Schauble, J. F., Langer, A., Heilman, M. S., Kolenik, S. A., Fischell, R. E., et al. (1980) · New England Journal of Medicine · doi:10.1056/nejm198008073030607 · Cited by 1,361
Responsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
Metscher, B. D. (2009) · BMC Physiology · doi:10.1186/1472-6793-9-11 · Cited by 1,086
Subthalamic nucleus stimulation in severe obsessive-compulsive disorder
Mallet, L., Polosan, M., Jaafari, N., Baup, N., Welter, M.-L., Fontaine, D., Montcel, S. T. D., Yelnik, J., Chéreau, I., Arbus, C., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708514 · Cited by 965
Cook, M. J., O'Brien, T. J., Berkovic, S. F., Murphy, M., Morokoff, A., Fabinyi, G., D'Souza, W., Yerra, R., Archer, J., Litewka, L., et al. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70075-9 · Cited by 879
Self-citationAn image-based modeling framework for patient-specific computational hemodynamics
Antiga, L., Piccinelli, M., Botti, L., Ene-Iordache, B., Remuzzi, A., & Steinman, D. A. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0420-1 · Cited by 850
Impedance Characterization and Modeling of Electrodes for Biomedical Applications
Franks, W., Schenker, I., Schmutz, P., & Hierlemann, A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847523 · Cited by 659
Innovative Interventional and Imaging Registries: Precision Medicine in Cerebrovascular Disorders
Liebeskind, D. S. (2015) · Interventional Neurology · doi:10.1159/000438773 · Cited by 608
Allison, T., McCarthy, G., Wood, C. C., Darcey, T. M., Spencer, D. D., & Williamson, P. D. (1989) · Journal of Neurophysiology · doi:10.1152/jn.1989.62.3.694 · Cited by 566
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
An Electrocorticographic Brain Interface in an Individual with Tetraplegia
Wang, W., Collinger, J. L., Degenhart, A. D., Tyler-Kabara, E. C., Schwartz, A. B., Moran, D. W., Weber, D. J., Wodlinger, B., Vinjamuri, R. K., Ashmore, R. C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055344 · Cited by 402
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399
An Intracardiac Pacemaker for Stokes-Adams Seizures
Furman, S., & Schwedel, J. B. (1959) · New England Journal of Medicine · doi:10.1056/nejm195911052611904 · Cited by 389
Cedzich, C., Taniguchi, M., Schäfer, S., & Schramm, J. (1996) · Neurosurgery · doi:10.1097/00006123-199605000-00023 · Cited by 344
Fortescue, E. B., Berul, C. I., Cecchin, F., Walsh, E. P., Triedman, J. K., & Alexander, M. E. (2004) · Heart Rhythm · doi:10.1016/j.hrthm.2004.02.020 · Cited by 275
The impact of chronic blood–brain barrier breach on intracortical electrode function
Saxena, T., Karumbaiah, L., Gaupp, E. A., Patkar, R., Patil, K., Betancur, M., Stanley, G. B., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.03.007 · Cited by 266
Electrocorticographic control of a prosthetic arm in paralyzed patients
Yanagisawa, T., Hirata, M., Saitoh, Y., Kishima, H., Matsushita, K., Goto, T., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2012) · Annals of Neurology · doi:10.1002/ana.22613 · Cited by 256
Relationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Pregnancy Decreases the Requirement for Inhaled Anesthetic Agents
Palahniuk, R. J., Shnider, S. M., & Eger, E. I. (1974) · Anesthesiology · doi:10.1097/00000542-197407000-00021 · Cited by 213
The Incidence of Venous Thrombosis Following Long-Term Transvenous Pacing
Stoney, W. S., Addlestone, R. B., Alford, W. C., Burrus, G. R., Frist, R. A., & Thomas, C. S. (1976) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(10)63980-x · Cited by 210
Retinal Prostheses: Current Clinical Results and Future Needs
Weiland, J. D., Cho, A. K., & Humayun, M. S. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.08.042 · Cited by 199
Dill, T., Neumann, T., Ekinci, O., Breidenbach, C., John, A., Erdogan, A., Bachmann, G., Hamm, C. W., & Pitschner, H.-F. (2003) · Circulation · doi:10.1161/01.cir.0000048146.81336.1d · Cited by 193
Venous sinus stenting for idiopathic intracranial hypertension: a review of the literature
Puffer, R. C., Mustafa, W., & Lanzino, G. (2013) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2012-010468 · Cited by 188
Shimoda, K., Nagasaka, Y., Chao, Z. C., & Fujii, N. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/3/036015 · Cited by 117
Henle, C., Raab, M., Cordeiro, J. G., Doostkam, S., Schulze‐Bonhage, A., Stieglitz, T., & Rickert, J. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9471-9 · Cited by 104
Neural decoding using gyral and intrasulcal electrocorticograms
Yanagisawa, T., Hirata, M., Saitoh, Y., Kato, A., Shibuya, D., Kamitani, Y., & Yoshimine, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.069 · Cited by 101
Lukatch, H. S., Kiddoo, C. E., & MacIver, M. B. (2005) · Cerebral Cortex · doi:10.1093/cercor/bhi015 · Cited by 94
Villeneuve, M. Y., & Casanova, C. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00198-5 · Cited by 78
Bundy, D. T., Zellmer, E. R., Gaona, C. M., Sharma, M., Szrama, N. P., Hacker, C. D., Freudenburg, Z. V., Daitch, A. L., Moran, D. W., & Leuthardt, E. C. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016006 · Cited by 63
Mechanosensory projections to cerebral cortex of sheep
Johnson, J. I., Rubel, E. W., & Hatton, G. I. (1974) · The Journal of Comparative Neurology · doi:10.1002/cne.901580106 · Cited by 57
Intravascular intracranial EEG recording
Penn, R. D., Hilal, S. K., Michelsen, W. J., Goldensohn, E. S., & Driller, J. (1973) · Journal of neurosurgery · doi:10.3171/jns.1973.38.2.0239 · Cited by 46
Computational modeling of an endovascular approach to deep brain stimulation
Teplitzky, B. A., Connolly, A. T., Bajwa, J. A., & Johnson, M. D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026011 · Cited by 44
Hoffmann, A., Stoffel, M. H., Nitzsche, B., Lobsien, D., Seeger, J., Schneider, H., & Boltze, J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0092990 · Cited by 43
Ogawa, T., Shingu, K., Shibata, M., Osawa, M., & Mori, K. (1992) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03008298 · Cited by 42
Intravenous recording of intracranial, broadband EEG
Bower, M. R., Stead, M., Gompel, J. J. V., Bower, R. S., Šulc, V., Asirvatham, S. J., & Worrell, G. A. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.12.027 · Cited by 41
Intravascular neural interface with nanowire electrode
Watanabe, H., Takahashi, H., Nakao, M., Walton, K. D., & Llinás, R. R. (2009) · Electronics and Communications in Japan · doi:10.1002/ecj.10058 · Cited by 37
“Cavernous Sinus EEG”: A New Method for the Preoperative Evaluation of Temporal Lobe Epilepsy
Mikuni, N., Ikeda, A., Murao, K., Terada, K., NAKAHARA, I., Taki, W., Kikuchi, H., & Shibasaki, H. (1997) · Epilepsia · doi:10.1111/j.1528-1157.1997.tb01738.x · Cited by 35
Gain of the human dura in vivo and its effects on invasive brain signal feature detection
Torres, A., Oostenveld, R., Vansteensel, M. J., Huiskamp, G. J. M., & Ramsey, N. F. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.01.019 · Cited by 34
24.1 A miniaturized 64-channel 225μW wireless electrocorticographic neural sensor
Muller, R., Le, H., Li, W., Ledochowitsch, P., Gambini, S., Björninen, T., Koralek, A. C., Carmena, J. M., Maharbiz, M. M., Alon, E., et al. (2014) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2014.6757492 · Cited by 33
Cited by
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Hydrogel interfaces for merging humans and machines
Yuk, H., Wu, J., & Zhao, X. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00483-4 · Cited by 661
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Metadata
- Authors
- Oxley, T. J., Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Wheeler, T. L., Judy, J. W., McDonald, A. J., Dornom, A., Lovell, T. J. H., Steward, C., Garrett, D. J., Moffat, B. A., Lui, E. H., Yassi, N., Campbell, B. C. V., Wong, Y. T., Fox, K. E., Nurse, E. S., Bennett, I. E., Bauquier, S. H., Liyanage, K. A., van der Nagel, N. R., Perucca, P., Ahnood, A., Gill, K. P., Yan, B., Churilov, L., French, C. R., Desmond, P. M., Horne, M. K., Kiers, L., Prawer, S., Davis, S. M., Burkitt, A. N., Mitchell, P. J., Grayden, D. B., May, C. N., & O'Brien, T. J.
- Venue
- Nature Biotechnology
- Published
- 2016-02-08
- Volume
- 34
- Issue
- 3
- Pages
- 320-327
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2253606866
- Cited by
- 339
- References
- 56
- FWCI
- 13.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.