The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Minimally invasive endovascular stent-electrode array for high-fidelity, chronic recordings of cortical neural activity
Open accessAbstract
High-fidelity intracranial electrode arrays for recording and stimulating brain activity have facilitated major advances in the treatment of neurological conditions over the past decade. Traditional arrays require direct implantation into the brain via open craniotomy, which can lead to inflammatory tissue responses, necessitating development of minimally invasive approaches that avoid brain trauma. Here we demonstrate the feasibility of chronically recording brain activity from within a vein using a passive stent-electrode recording array (stentrode). We achieved implantation into a superficial cortical vein overlying the motor cortex via catheter angiography and demonstrate neural recordings in freely moving sheep for up to 190 d. Spectral content and bandwidth of vascular electrocorticography were comparable to those of recordings from epidural surface arrays. Venous internal lumen patency was maintained for the duration of implantation. Stentrodes may have wide ranging applications as a neural interface for treatment of a range of neurological conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, Q., Wang, C., Zheng, M., Li, Y., Li, J., Zhang, L., Shang, X., & Yan, C. (2015) · Cerebrovascular Diseases · doi:10.1159/000369778 · Cited by 11,533
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323
3D Slicer as an image computing platform for the Quantitative Imaging Network
Fedorov, A., Beichel, R., Kalpathy-Cramer, J., Finet, J., Fillion-Robin, J.-C., Pujol, S., Bauer, C., Jennings, D., Fennessy, F., Sonka, M., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.05.001 · Cited by 9,023
A Randomized Trial of Intraarterial Treatment for Acute Ischemic Stroke
Berkhemer, O. A., Fransen, P. S. S., Beumer, D., van den Berg, L. A., Lingsma, H. F., Yoo, A. J., Schonewille, W. J., Vos, J. A., Nederkoorn, P. J., Wermer, M. J. H., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1411587 · Cited by 6,657
Cortical Surface-Based Analysis
Fischl, B., Sereno, M. I., & Dale, A. M. (1999) · NeuroImage · doi:10.1006/nimg.1998.0396 · Cited by 6,147
Endovascular Therapy for Ischemic Stroke with Perfusion-Imaging Selection
Campbell, B. C. V., Mitchell, P. J., Kleinig, T. J., Dewey, H. M., Churilov, L., Yassi, N., Yan, B., Dowling, R. J., Parsons, M. W., Oxley, T. J., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1414792 · Cited by 5,819
Self-citationSpectrum estimation and harmonic analysis
Thomson, D. J. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12433 · Cited by 4,418
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
A Randomized Trial of Deep-Brain Stimulation for Parkinson's Disease
Deuschl, G., Schade-Brittinger, C., Krack, P., Volkmann, J., Schäfer, H., Bötzel, K., Daniels, C., Deutschländer, A., Dillmann, U., Eisner, W., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa060281 · Cited by 2,944
Cited by
Materials and technologies for soft implantable neuroprostheses
Lacour, S. P., Courtine, G., & Guck, J. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.63 · Cited by 738
Hydrogel interfaces for merging humans and machines
Yuk, H., Wu, J., & Zhao, X. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00483-4 · Cited by 661
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Wang, L., Xie, S., Wang, Z., Liu, F., Yang, Y., Tang, C., Wu, X., Liu, P., Li, Y., Saiyin, H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0462-8 · Cited by 384
Progress in Brain Computer Interface: Challenges and Opportunities
Saha, S., Mamun, K. A., Ahmed, K., Mostafa, R., Naik, G. R., Darvishi, S., Khandoker, A. H., & Baumert, M. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.578875 · Cited by 365
Stable long-term chronic brain mapping at the single-neuron level
Fu, T.-M., Hong, G., Zhou, T., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2016) · Nature Methods · doi:10.1038/nmeth.3969 · Cited by 330
Han, M., Chen, L., Aras, K., Liang, C., Chen, X., Zhao, H., Li, K., Faye, N. R., Sun, B., Kim, J.-H., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00604-w · Cited by 324
Manford, M. (2017) · Journal of Neurology · doi:10.1007/s00415-017-8394-2 · Cited by 299
Emerging technologies for improved deep brain stimulation
Cagnan, H., Denison, T., McIntyre, C., & Brown, P. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0244-6 · Cited by 272
Oxley, T. J., Yoo, P. E., Rind, G. S., Ronayne, S. M., Lee, C. M. S., Bird, C., Hampshire, V., Sharma, R. P., Morokoff, A., Williams, D. L., et al. (2021) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2020-016862 · Cited by 243
Self-citationRecent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Simeral, J. D., Hosman, T., Saab, J., Flesher, S. N., Vilela, M., Franco, B., Kelemen, J. N., Brandman, D. M., Ciancibello, J. G., Rezaii, P. G., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069119 · Cited by 165
The Future of Neuroimplantable Devices: A Materials Science and Regulatory Perspective
Obidin, N., Tasnim, F., & Dagdeviren, C. (2020) · Advanced Materials · doi:10.1002/adma.201901482 · Cited by 126
Shi, Z., Zheng, F., Zhou, Z., Li, M., Fan, Z., Ye, H., Zhang, S., Xiao, T., Chen, L., Tao, T. H., et al. (2019) · Advanced Science · doi:10.1002/advs.201801617 · Cited by 94
Extending the limits of wireless power transfer to miniaturized implantable electronic devices
Dinis, H., Colmiais, I., & Mendes, P. (2017) · Micromachines · doi:10.3390/mi8120359 · Cited by 59
Near-Field Wireless Power Transfer to Stent-Based Biomedical Implants
Wiseman, G., Redoute, J.-M., Ganesan, K., Rind, G. S., John, S. E., Ronayne, S. M., Opie, N. L., Garrett, D. J., & Prawer, S. (2018) · IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2018.2833386 · Cited by 49
Self-citationLong-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients
Larzabal, C., Bonnet, S., Costecalde, T., Auboiroux, V., Charvet, G., Chabardes, S., Aksenova, T., & Sauter-Starace, F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2003 · Cited by 37
“This value is similar to the one reported by [30] and [40] from long-term sheep experiment whereas [27] reported about 100 Hz with a Nyquist frequency at 200 Hz.”
Magnetic nanomaterials for wireless thermal and mechanical neuromodulation
Signorelli, L., Hescham, S. A., Pralle, A., & Gregurec, D. (2022) · iScience · doi:10.1016/j.isci.2022.105401 · Cited by 32
Endovascular neuromodulation: safety profile and future directions
Raza, S. A., Opie, N. L., Morokoff, A., Sharma, R. P., Mitchell, P. J., & Oxley, T. J. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00351 · Cited by 29
Self-citationRecent advances in recording and modulation technologies for next-generation neural interfaces.
Hong, J.-W., Yoon, C., Jo, K., Won, J. H., & Park, S. (2021) · iScience · doi:10.1016/j.isci.2021.103550 · Cited by 25
Transient neurovascular interface for minimally invasive neural recording and stimulation
Fanelli, A., Ferlauto, L., Zollinger, E. G., Brina, O., Reymond, P., Machi, P., & Ghezzi, D. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202100176 · Cited by 22
Neurophysiological considerations for visual implants
Meikle, S. J., & Wong, Y. T. (2022) · Brain Structure and Function · doi:10.1007/s00429-021-02417-2 · Cited by 15
Self-citation
Metadata
- Authors
- Oxley, T. J., Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Wheeler, T. L., Judy, J. W., McDonald, A. J., Dornom, A., Lovell, T. J. H., Steward, C., Garrett, D. J., Moffat, B. A., Lui, E. H., Yassi, N., Campbell, B. C. V., Wong, Y. T., Fox, K. E., Nurse, E. S., Bennett, I. E., Bauquier, S. H., Liyanage, K. A., van der Nagel, N. R., Perucca, P., Ahnood, A., Gill, K. P., Yan, B., Churilov, L., French, C. R., Desmond, P. M., Horne, M. K., Kiers, L., Prawer, S., Davis, S. M., Burkitt, A. N., Mitchell, P. J., Grayden, D. B., May, C. N., & O'Brien, T. J.
- Venue
- Nature Biotechnology
- Published
- 2016-02-08
- Volume
- 34
- Issue
- 3
- Pages
- 320-327
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2253606866
- Cited by
- 339
- References
- 56
- FWCI
- 13.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.