Electrochemical DNA sensors
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Electrochemistry-based sensors offer sensitivity, selectivity and low cost for the detection of selected DNA sequences or mutated genes associated with human disease. DNA-based electrochemical sensors exploit a range of different chemistries, but all take advantage of nanoscale interactions between the target in solution, the recognition layer and a solid electrode surface. Numerous approaches to electrochemical detection have been developed, including direct electrochemistry of DNA, electrochemistry at polymer-modified electrodes, electrochemistry of DNA-specific redox reporters, electrochemical amplifications with nanoparticles, and electrochemical devices based on DNA-mediated charge transport chemistry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scanometric DNA Array Detection with Nanoparticle Probes
Taton, T. A., Mirkin, C. A., & Letsinger, R. L. (2000) · Science · doi:10.1126/science.289.5485.1757 · Cited by 2,411
Storhoff, J. J., Elghanian, R., Mucic, R. C., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972332i · Cited by 2,271
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
A Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
Array-Based Electrical Detection of DNA with Nanoparticle Probes
Park, S.-J., Taton, T. A., & Mirkin, C. A. (2002) · Science · doi:10.1126/science.1067003 · Cited by 1,515
Electrochemical Quantitation of DNA Immobilized on Gold
Steel, A. B., Herne, T. M., & Tarlov, M. J. (1998) · Analytical Chemistry · doi:10.1021/ac980037q · Cited by 1,328
Ramsay, G. (1998) · Nature Biotechnology · doi:10.1038/nbt0198-40 · Cited by 781
Mutation detection by electrocatalysis at DNA-modified electrodes
Boon, E. M., Ceres, D. M., Drummond, T. G., Hill, M. G., & Barton, J. K. (2000) · Nature Biotechnology · doi:10.1038/80301 · Cited by 639
Self-citationElectrochemical nucleic acid biosensors
Wang, J. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01399-x · Cited by 614
Electrochemical Coding Technology for Simultaneous Detection of Multiple DNA Targets
Wang, J., Liu, G., & Merkoçi, A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja029668z · Cited by 612
Research works printed but not linked: 1
- Ji, J. & Manak, M. Genotyping of single nucleotide polymorphisms for epidemiological studies: a review of current methods. J. Clin. Ligand Assay 25, 199–210 (2002).
Cited by
Items 501–600 of 1,001
Individual Au-Nanocube Based Plasmonic Nanoprobe for Cancer Relevant MicroRNA Biomarker Detection
Zhang, L., Wang, J., Zhang, J., Liu, Y., Wu, L., Shen, J., Zhang, Y., Hu, Y., Fan, Q., Huang, W., et al. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00322 · Cited by 67
Tuning the Bacterial Detection Sensitivity of Nanostructured Microelectrodes
Das, J., & Kelley, S. O. (2013) · Analytical Chemistry · doi:10.1021/ac401221f · Cited by 67
Immunomagnetic Diffractometry for Detection of Diagnostic Serum Markers
Acharya, G. S., Chang, C.-L., Doorneweerd, D. D., Vlashi, E., Henne, W. A., Hartmann, L. C., Low, P. S., & Savran, C. A. (2007) · Journal of the American Chemical Society · doi:10.1021/ja073094m · Cited by 73
Nakamura, N., Ito, K., Takahashi, M., Hashimoto, K., Kawamoto, M., Yamanaka, M., Taniguchi, A., Kamatani, N., & Gemma, N. (2007) · Analytical Chemistry · doi:10.1021/ac0715468 · Cited by 76
Electrochemical DNA Biosensors Based on Palladium Nanoparticles Combined with Carbon Nanotubes
Chang, Z., Fan, H., Zhao, K., Chen, M., He, P., & Fang, Y. (2007) · Electroanalysis · doi:10.1002/elan.200704023 · Cited by 66
Mirmomtaz, E., Castronovo, M., Grunwald, C., Bano, F., Scaini, D., Ensafi, A. A., Scoles, G., & Casalis, L. (2008) · Nano Letters · doi:10.1021/nl802722k · Cited by 72
Electrochemistry of Nucleic Acids
Paleček, E., & Jelen, F. (2005) · Perspectives in bioanalysis · doi:10.1016/s1871-0069(05)01003-7 · Cited by 70
Electrochemical determination of microRNA-21 based on bio bar code and hemin/G-quadruplet DNAenzyme
Meng, X., Zhou, Y., Liang, Q., Qu, X., Yang, Q., Yin, H., & Ai, S. (2013) · The Analyst · doi:10.1039/c3an36788f · Cited by 66
Min, K., Song, K.-M., Cho, M., Chun, Y., Shim, Y., Ku, J. K., & Ban, C. (2010) · Chemical Communications · doi:10.1039/c002524k · Cited by 66
Low, S. S., Loh, H., Boey, J. S., Khiew, P. S., Chiu, W. S., & Tan, M. T. T. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.02.038 · Cited by 66
Synthesis and Biomedical Applications of Graphene: Present and Future Trends
Kumar, A., & Huei, C. (2013) · InTech eBooks · doi:10.5772/55728 · Cited by 65
“Major studies on DNA have focused on the sequence-specific recognition and mutation of the single stranded DNA (ss-DNA) by various techniques [65-68].”
Rapid, specific and sensitive electrochemical detection of foodborne bacteria
Pöhlmann, C., Wang, Y., Humeník, M., Heidenreich, B., Gareis, M., & Sprinzl, M. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.01.042 · Cited by 65
Raytchev, M., Mayer, E., Amann, N., Wagenknecht, H., & Fiebig, T. (2004) · ChemPhysChem · doi:10.1002/cphc.200301205 · Cited by 65
LaGier, M. J., Fell, J. W., & Goodwin, K. D. (2007) · Marine Pollution Bulletin · doi:10.1016/j.marpolbul.2006.12.017 · Cited by 65
Wang, L., Chen, X., Wang, X., Han, X., Liu, S., & Zhao, C. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.09.003 · Cited by 65
Das, R., Sharma, M. K., Rao, V. K., Bhattacharya, B. K., Garg, I., Venkatesh, V., & Upadhyay, S. (2014) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2014.08.002 · Cited by 65
Real-Time Electrochemical Monitoring of the Polymerase Chain Reaction by Mediated Redox Catalysis
Deféver, T., Druet, M., Dequaire, M., Joannes, M., Grossiord, C., Limoges, B., & Marchal, D. (2009) · Journal of the American Chemical Society · doi:10.1021/ja901368m · Cited by 67
Metal-containing peptide nucleic acid conjugates
Gasser, G., Sosniak, A. M., & Metzler‐Nolte, N. (2011) · Dalton Transactions · doi:10.1039/c0dt01706j · Cited by 67
Sakata, T., Maruyama, S., Ueda, A., Otsuka, H., & Miyahara, Y. (2007) · Langmuir · doi:10.1021/la0616193 · Cited by 65
Zhou, H., Yang, D., Dina, N. E., Ivleva, N. P., Schwarzmeier, K., Wieser, A., Schubert, S., Nießner, R., & Haisch, C. (2015) · Microchimica Acta · doi:10.1007/s00604-015-1570-0 · Cited by 65
“tinction and require for larger reactant volumes and additional preparation steps, which greatly diminishes their efficiency [22, 23].”
BackgroundRowe, A. A., Chuh, K. N., Lubin, A. A., Miller, E. A., Cook, B. M., Hollis, D., & Plaxco, K. W. (2011) · Analytical Chemistry · doi:10.1021/ac202171x · Cited by 65
Scalable Production of Sensor Arrays Based on High-Mobility Hybrid Graphene Field Effect Transistors
Gao, Z., Kang, H., Naylor, C. H., Streller, F., Ducos, P., Serrano, M. D., Ping, J., Zauberman, J., Rajesh, R., Carpick, R. W., et al. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b09238 · Cited by 65
Clinical Applications of Micro‐ and Nanoscale Biosensors
Morrison, D. W. G., Dokmeci, M. R., Demirci, U., & Khademhosseini, A. (2007) · Wiley eBooks · doi:10.1002/9780470185834.ch17 · Cited by 65
Li, C., Li, X., Wei, L., Liu, M., Chen, Y., & Li, G. (2015) · Chemical Science · doi:10.1039/c5sc00891c · Cited by 64
DNA Charge Transport within the Cell
Grodick, M. A., Muren, N. B., & Barton, J. K. (2015) · Biochemistry · doi:10.1021/bi501520w · Cited by 65
Self-citationElectrochemical Detection of Single-Nucleotide Mismatches Using an Electrode Microarray
Li, X., Lee, J. S., & Kraatz, H. (2006) · Analytical Chemistry · doi:10.1021/ac060533b · Cited by 64
Kuga, S., Yang, J.-H., Takahashi, H., Hirama, K., Iwasaki, T., & Kawarada, H. (2008) · Journal of the American Chemical Society · doi:10.1021/ja710167z · Cited by 64
Opto-electronic DNA chip: high performance chip reading with an all-electric interface
Mallard, F., Marchand, G., Ginot, F., & Campagnolo, R. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.07.031 · Cited by 64
Microcantilever: Dynamical Response for Mass Sensing and Fluid Characterization
Mouro, J., Pinto, R. M. R., Paoletti, P., & Tiribilli, B. (2020) · Sensors · doi:10.3390/s21010115 · Cited by 69
“Depending on the target analyte to be detected, one can use antibodies, synthetic oligonucleotides, locked nucleic acids (LNA), or aptamers as recognition elements [79].”
BackgroundShervedani, R. K., & Bagherzadeh, M. (2008) · Electrochimica Acta · doi:10.1016/j.electacta.2008.04.051 · Cited by 63
Domı́nguez, E., Rincón, Ó., & Narváez, A. (2004) · Analytical Chemistry · doi:10.1021/ac0499672 · Cited by 63
An impedance-based integrated biosensor for suspended DNA characterization
Ma, H., Wallbank, R. W. R., Chaji, R., Li, J., Suzuki, Y., Jiggins, C. D., & Nathan, A. (2013) · Scientific Reports · doi:10.1038/srep02730 · Cited by 63
Charging Behavior of Single-Stranded DNA Polyelectrolyte Brushes
Shen, G., Tercero, N., Gaspar, M. A., Varughese, B., Shepard, K. L., & Levicky, R. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0571500 · Cited by 63
Wu, Y., Zhang, D. Y., Yin, P., & Vollmer, F. (2014) · Small · doi:10.1002/smll.201303558 · Cited by 63
Solution, surface, and single molecule platforms for the study of DNA-mediated charge transport
Muren, N. B., Olmon, E. D., & Barton, J. K. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41602f · Cited by 65
Self-citationEmre Özkumur, A., Ahn, S., Ayça Yalçın, A., A, C. A. L., Çevik, E., Irani, R. J., DeLisi, C., Chiari, M., & Ünlü, M. S. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.032 · Cited by 66
“Electrochemical DNA sensors (Drummond et al., 2003; Kelley et al., 1999; Weng et al., 2008), carbon nanotube (CNT) electrode arrays (J.”
BackgroundShiddiky, M. J. A., Torriero, A. A. J., Zeng, Z., Spiccia, L., & Bond, A. M. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1021365 · Cited by 62
Silicene-based DNA nucleobase sensing
Sadeghi, H., Bailey, S., & Lambert, C. J. (2014) · Applied Physics Letters · doi:10.1063/1.4868123 · Cited by 62
Labeled magnetic nanoparticles assembly on polypyrrole film for biosensor applications
Fredj, H. B., Helali, S., Esseghaier, C., Vonna, L., Vidal, L., & Abdelghani, A. (2008) · Talanta · doi:10.1016/j.talanta.2007.12.034 · Cited by 62
Nanostructured CMOS Wireless Ultra-Wideband Label-Free PCR-Free DNA Analysis SoC
Jafari, H. M., Abdelhalim, K., Soleymani, L., Sargent, E. H., Kelley, S. O., & Genov, R. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2312571 · Cited by 62
“Amperometric electrochemical DNA sensors [15], [19]–[22], [30], [32]–[34] have emerged as a low-cost, high-throughput, and real-time alternative to conventional optical and electrochemical sensory methods.”
BackgroundJambrec, D., Gebala, M. K., Mantia, F. L., & Schuhmann, W. W. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201506672 · Cited by 62
Mao, X., Mao, D., Chen, T., Jalalah, M., Al-Assiri, M. S., Harraz, F. A., Zhu, X., & Li, G. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c08064 · Cited by 62
Jafari, S., Faridbod, F., Norouzi, P., Dezfuli, A. S., Ajloo, D., Mohammadipanah, F., & Ganjali, M. R. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.05.055 · Cited by 61
Tarai, A., Li, Y., Liu, B., Zhang, D., Li, J., Yan, W., Zhang, J., Qu, J., & Yang, Z. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214070 · Cited by 62
Microfabrication of biomedical lab-on-chip devices. A review; pp. 109–139
Giannitsis, A. T. (2011) · Estonian Journal of Engineering · doi:10.3176/eng.2011.2.03 · Cited by 61
Sakata, T., Ihara, M., Makino, I., Miyahara, Y., & Ueda, H. (2009) · Analytical Chemistry · doi:10.1021/ac900457m · Cited by 61
Single-molecule observation of DNA charge transfer
Takada, T., Fujitsuka, M., & Majima, T. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700795104 · Cited by 62
Chemically Modified Electrodes
Edwards, G. A., Bergren, A. J., & Porter, M. D. (2007) · Elsevier eBooks · doi:10.1016/b978-044451958-0.50021-5 · Cited by 61
Stimuli-responsive polymer-based systems for diagnostic applications
Shu, T., Hu, L., Shen, Q., Jiang, L., Zhang, Q. M., & Serpe, M. J. (2020) · Journal of Materials Chemistry B · doi:10.1039/d0tb00570c · Cited by 62
DNA Hybridization Detection at Heated Electrodes
Flechsig, G., Peter, J., Hartwich, G., Wang, J., & Gründler, P. (2005) · Langmuir · doi:10.1021/la051176n · Cited by 61
Fluorescent polyelectrolytes as protein sensors
Ambade, A. V., Sandanaraj, B. S., Klaikherd, A., & Thayumanavan, S. (2006) · Polymer International · doi:10.1002/pi.2185 · Cited by 61
Zhuang, J., Tang, D., Lai, W., Chen, G., & Yang, H. (2014) · Analytical Chemistry · doi:10.1021/ac501986k · Cited by 60
Hybridization Biosensors Relying on Electrical Properties of Nucleic Acids
Ferapontova, E. E. (2016) · Electroanalysis · doi:10.1002/elan.201600593 · Cited by 60
Estrada-Osorio, D. V., Escalona-Villalpando, R. A., Gutiérrez, A., Arriaga, L. G., & García, J. L. (2022) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2022.108147 · Cited by 60
Impedimetric genosensors employing COOH-modified carbon nanotube screen-printed electrodes
Bonanni, A., Esplandiu, M. J., & del Valle, M. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.02.023 · Cited by 60
“…bacteria and viruses is the eparture point to solve different problems: investigation about ood and water contamination caused by micro organisms, detecion of genetic disorders, identification of species, tissue matching, orensic applications, etc. (Drummond et al., 2003; Righetti and elfi, 1997).”
BackgroundSun, W., Zhong, J., Qin, P., & Jiao, K. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.03.027 · Cited by 60
Electrically monitoring DNA repair by photolyase
DeRosa, M. C., Sancar, A., & Barton, J. K. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503527102 · Cited by 68
Self-citationDauphin‐Ducharme, P., Arroyo‐Currás, N., & Plaxco, K. W. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b11341 · Cited by 60
Controlling Matter at the Molecular Scale with DNA Circuits
Scalise, D., & Schulman, R. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052357 · Cited by 62
Turcu, F., Schulte, A., Hartwich, G., & Schuhmann, W. W. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.06.011 · Cited by 60
Biointerface Engineering with Nucleic Acid Materials for Biosensing Applications
Shi, S., Chen, J., Wang, X., Xiao, M., Chandrasekaran, A. R., Li, L., Yi, C., & Pei, H. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202201069 · Cited by 66
DNA sensors based on CNT-FET with floating electrodes
Kim, B.-J., Lee, J., Namgung, S., Kim, J., Park, J. Y., Lee, M.-S., & Hong, S. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.04.063 · Cited by 59
Chemistry of nucleic acids: impacts in multiple fields
Khakshoor, O., & Kool, E. T. (2011) · Chemical Communications · doi:10.1039/c1cc11021g · Cited by 64
Arora, K., Prabhakar, N., Chand, S., & Malhotra, B. D. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.04.029 · Cited by 59
İnci, F., Filippini, C., Baday, M., Ozen, M. O., Çalamak, S., Durmus, N. G., Wang, S., Hanhauser, E., Hobbs, K. S., Juillard, F., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1510824112 · Cited by 59
Electrochemical Patterning and Detection of DNA Arrays on a Two-Electrode Platform
Furst, A. L., Landefeld, S., Hill, M. G., & Barton, J. K. (2013) · Journal of the American Chemical Society · doi:10.1021/ja410902j · Cited by 58
Self-citationElectrochemical Nucleic Acid Biosensors
Wang, J. (2005) · Perspectives in bioanalysis · doi:10.1016/s1871-0069(05)01004-9 · Cited by 59
A novel signal-on electrochemical DNA sensor based on target catalyzed hairpin assembly strategy
Qian, Y., Tang, D., Du, L., Zhang, Y., Zhang, L., & Gao, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.001 · Cited by 58
Transient Out‐of‐Equilibrium Nucleic Acid‐Based Dissipative Networks and Their Applications
Li, Z., Wang, J., & Willner, I. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202200799 · Cited by 58
Advanced strategies for enzyme–electrode interfacing in bioelectrocatalytic systems
Lee, H., Reginald, S. S., Sravan, J. S., Lee, M., & Chang, I. S. (2024) · Trends in biotechnology · doi:10.1016/j.tibtech.2024.11.015 · Cited by 64
A Wireless IC for Time-Share Chemical and Electrical Neural Recording
Roham, M., Covey, D. P., Daberkow, D. P., Ramsson, E. S., Howard, C. D., Heidenreich, B. A., Garris, P. A., & Mohseni, P. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2035549 · Cited by 60
“ical methods have previously been used for specific detection of biomolecules in biomedical applications [20]–[23] as well as trace detection of heavy metals in situ for environmental applications [24].”
MethodBa-Shami, R. M., Hameed, A., Aslam, M., Ismail, I. M. I., & Soomro, M. T. (2015) · Analytical Methods · doi:10.1039/c4ay02857k · Cited by 58
Huang, K.-C., & White, R. J. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4060788 · Cited by 58
Graphene based biosensors for healthcare
Terse-Thakoor, T., Badhulika, S., & Mulchandani, A. (2017) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2017.175 · Cited by 59
Developing nucleic acid-based electrical detection systems
Gabig‐Cimińska, M. (2006) · Microbial Cell Factories · doi:10.1186/1475-2859-5-9 · Cited by 58
“This type of sensors assures the high sensitivities, although paying greater attention label-independent electrical detection systems are even more promising, especially for application where for instance the analysis duration is more critical than the detection limit, or where the direct real time monitoring is desir…”
Biomolecular engineering at interfaces
He, L., Dexter, A. F., & Middelberg, A. P. J. (2005) · Chemical Engineering Science · doi:10.1016/j.ces.2005.05.064 · Cited by 62
Li, Y., Liu, D., Meng, S., Zhang, J., Li, L., & You, T. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c04501 · Cited by 57
Dual harmonic Kelvin probe force microscopy at the graphene–liquid interface
Collins, L. F., Kilpatrick, J. I., Vlassiouk, I., Tselev, A., Weber, S. A. L., Jesse, S., Kalinin, S. V., & Rodriguez, B. J. (2014) · Applied Physics Letters · doi:10.1063/1.4870074 · Cited by 57
Electrochemical response of oligonucleotides on carbon paste electrode
Stempkowska, I., Ligaj, M., Jasnowska, J., Langer, J. J., & Filipiak, M. (2006) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2006.07.012 · Cited by 57
Miao, J., Cao, Z., Zhou, Y., Lau, C., & Lu, J. (2008) · Analytical Chemistry · doi:10.1021/ac7022553 · Cited by 57
Ben‐Yoav, H., Dykstra, P. H., Bentley, W. E., & Reza Ghodssi, A. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.05.009 · Cited by 57
“Electrical sensors have been demonstrated for impedance, conductance or capacitance measurements of DNA hybridization and can be easily fabricated and integrated with common test equipment (Drummond et al., 2003; Gautier et al., 2007; Goral et al., 2006).”
BackgroundThe electrochemical applications of quantum dots
Huang, H., & Zhu, J. (2013) · The Analyst · doi:10.1039/c3an01034a · Cited by 62
Gao, Y., Deng, X., Wen, W., Zhang, X., & Wang, S. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.068 · Cited by 57
“(Drummond et al., 2003, Gooding, J. J., 2002) Among all kinds of reporter particles, AuNPs are most commonly used in LFA because of their long-terms stability, and good biocompatibility with proteins, DNA, and RNA (Hou et al., 2007).”
BackgroundFerrocenyl‐Modified DNA: Synthesis, Characterization and Integration with Semiconductor Electrodes
Pike, A. R., Ryder, L. C., Horrocks, B. R., Clegg, W., Connolly, B. A., & Houlton, A. (2004) · Chemistry - A European Journal · doi:10.1002/chem.200400632 · Cited by 57
DNA-based nanostructures for molecular sensing
Lee, J. B., Campolongo, M. J., Kahn, J. S., Roh, Y. H., Hartman, M. R., & Luo, D. (2009) · Nanoscale · doi:10.1039/b9nr00142e · Cited by 56
An electrochemical immunosensing method for detecting melanoma cells
Seenivasan, R., Maddodi, N., Setaluri, V., & Gunasekaran, S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.01.022 · Cited by 57
“…these, the electrochemical methods have many advantages such as simple, rapid, inexpensive, unaffected by sample turbidity, and ultrasensitive for detecting various target analytes in complex biological samples (Drummond et al., 2003; Karimi-Maleh et al., 2013, 2014a, 2014b; Moradi et al., 2013).”
BackgroundGold nanoparticle embedded silicon nanowire biosensor for applications of label-free DNA detection
Ryu, S., Kim, C., Han, J.-W., Kim, C.-J., Jung, C., Park, H. G., & Choi, Y. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.02.010 · Cited by 56
“…factors for a variety of transducers, such s the microbalance (Caruso et al., 1997), surface plasmon resoance (SPR) spectroscopy (Homola et al., 1999), fluorescent assays Chehab and Kan, 1989), biomechanical cantilever array (Fritz et al., 000), and electrochemistry (Drummond et al., 2003).”
BackgroundZhang, W., Zhang, R., Zhang, J., Ye, Z., Jin, D., & Yuan, J. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.028 · Cited by 56
Qian, H., & He, L. (2009) · Analytical Chemistry · doi:10.1021/ac900401m · Cited by 61
Ping‐Pong Electron Transfer through DNA
Elias, B., Genereux, J. C., & Barton, J. K. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803556 · Cited by 56
Self-citationFunctionalized multi-wall carbon nanotubes as an efficient additive for electrochemical DNA sensor
Li, J., & Lee, E. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.08.068 · Cited by 56
Lin, D., Wu, Q., Qiu, S., Chen, G., Feng, S., Chen, R., & Zeng, H. (2019) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2019.102100 · Cited by 56
Chemiluminescence microarrays in analytical chemistry: a critical review
Seidel, M., & Nießner, R. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7968-4 · Cited by 61
“Analytical microarrays can be differentiated by the readout system used, and fluorescence [2], electrochemical [3, 4], chemiluminescence (CL) [5–8], or labelfree microarray readout systems [9–11] have been used.”
The Current and Future Role of Aptamers in Electroanalysis
Liu, J., Morris, M. D., Macazo, F. C., Schoukroun-Barnes, L. R., & White, R. J. (2014) · Journal of The Electrochemical Society · doi:10.1149/2.026405jes · Cited by 60
Label-Free Detection of Telomerase Activity Using Guanine Electrochemical Oxidation Signal
Eskiocak, U., Ozkan‐Ariksoysal, D., Özsöz, M., & Öktem, H. A. (2007) · Analytical Chemistry · doi:10.1021/ac071014r · Cited by 55
Tateishi‐Karimata, H., Nakano, M., & Sugimoto, N. (2014) · Scientific Reports · doi:10.1038/srep03593 · Cited by 55
Arotiba, O. A., Owino, J., Songa, E. A., Hendricks, N. R., Waryo, T., Jahed, N. M., Baker, P., & Iwuoha, E. I. (2008) · Sensors · doi:10.3390/s8116791 · Cited by 55
“The common bioreceptors are enzyme [1-4], antibody [5, 6], DNA [7, 8] and whole cell [9], while transduction methods include electrochemical, pizoelectric, optical, etc.”
BackgroundIto, T., Hosokawa, K., & Maeda, M. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.08.008 · Cited by 55
Wu, C.-C., Ku, B.-C., Ko, C.-H., Chiu, C.-C., Wang, G., Yang, Y.-H., & Wu, S.-J. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.04.132 · Cited by 57
Nanobiosensor for Detection and Quantification of DNA Sequences in Degraded Mixed Meats
Ali, M. E., Hashim, U., Mustafa, S., Man, Y. B. C., Yusop, M. H. M., Kashif, M., Dhahi, T. S., Bari, M. F., Hakim, M. A., & Latif, A. (2011) · Journal of Nanomaterials · doi:10.1155/2011/781098 · Cited by 55
Metadata
- Authors
- Drummond, T. G., Hill, M. G., & Barton, J. K.
- Affiliations
- California Institute of Technology (US)
- Occidental College (US)
- Corresponding author
- Barton, Jacqueline K
- Venue
- Nature Biotechnology
- Published
- 2003-10
- Volume
- 21
- Issue
- 10
- Pages
- 1192-1199
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2009040055
- Cited by
- 2,214
- References
- 57
- Citations by year
- 2026: 33 · 2025: 47 · 2024: 47 · 2023: 73 · 2022: 69 · 2021: 73 · 2020: 82 · 2019: 79 · 2018: 98 · 2017: 94 · 2016: 113 · 2015: 143 · 2014: 151 · 2013: 138 · 2012: 117
- FWCI
- 5.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- National Institutes of Health
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- electrochemical DNA biosensor, DNA detection, gene mutation detection, polymer-modified electrodes, redox reporter, nanoparticles, DNA-mediated charge transport
- MeSH terms
- DNA, Electrochemistry, Equipment Design, Membranes, Artificial, Proteins, Transducers, Biosensing Techniques, Coated Materials, Biocompatible, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.