Electrochemical DNA sensors
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Electrochemistry-based sensors offer sensitivity, selectivity and low cost for the detection of selected DNA sequences or mutated genes associated with human disease. DNA-based electrochemical sensors exploit a range of different chemistries, but all take advantage of nanoscale interactions between the target in solution, the recognition layer and a solid electrode surface. Numerous approaches to electrochemical detection have been developed, including direct electrochemistry of DNA, electrochemistry at polymer-modified electrodes, electrochemistry of DNA-specific redox reporters, electrochemical amplifications with nanoparticles, and electrochemical devices based on DNA-mediated charge transport chemistry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scanometric DNA Array Detection with Nanoparticle Probes
Taton, T. A., Mirkin, C. A., & Letsinger, R. L. (2000) · Science · doi:10.1126/science.289.5485.1757 · Cited by 2,411
Storhoff, J. J., Elghanian, R., Mucic, R. C., Mirkin, C. A., & Letsinger, R. L. (1998) · Journal of the American Chemical Society · doi:10.1021/ja972332i · Cited by 2,271
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
A Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
Array-Based Electrical Detection of DNA with Nanoparticle Probes
Park, S.-J., Taton, T. A., & Mirkin, C. A. (2002) · Science · doi:10.1126/science.1067003 · Cited by 1,515
Electrochemical Quantitation of DNA Immobilized on Gold
Steel, A. B., Herne, T. M., & Tarlov, M. J. (1998) · Analytical Chemistry · doi:10.1021/ac980037q · Cited by 1,328
Ramsay, G. (1998) · Nature Biotechnology · doi:10.1038/nbt0198-40 · Cited by 781
Mutation detection by electrocatalysis at DNA-modified electrodes
Boon, E. M., Ceres, D. M., Drummond, T. G., Hill, M. G., & Barton, J. K. (2000) · Nature Biotechnology · doi:10.1038/80301 · Cited by 639
Self-citationElectrochemical nucleic acid biosensors
Wang, J. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01399-x · Cited by 614
Electrochemical Coding Technology for Simultaneous Detection of Multiple DNA Targets
Wang, J., Liu, G., & Merkoçi, A. (2003) · Journal of the American Chemical Society · doi:10.1021/ja029668z · Cited by 612
Research works printed but not linked: 1
- Ji, J. & Manak, M. Genotyping of single nucleotide polymorphisms for epidemiological studies: a review of current methods. J. Clin. Ligand Assay 25, 199–210 (2002).
Cited by
Items 201–300 of 1,001
Biosensor Technologies for Early Detection and Quantification of Plant Pathogens
Dyussembayev, K., Sambasivam, P. T., Bar, I., Brownlie, J. C., Shiddiky, M. J. A., & Ford, R. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.636245 · Cited by 152
“The coupling of DNAbased analyte capture systems with electrochemical techniques to measure the quantity of capture has been included in the development of fungal plant pathogen diagnostics tools (Drummond et al., 2003; Privett et al., 2010).”
MethodElectrochemical DNA Biosensor Based on the Proximity-Dependent Surface Hybridization Assay
Zhang, Y., Wang, Y., Wang, H., Jiang, J., Shen, G., Yu, R., & Li, J. (2009) · Analytical Chemistry · doi:10.1021/ac802512d · Cited by 131
Interfacing Pathogen Detection with Smartphones for Point-of-Care Applications
Ding, X., Mauk, M. G., Yin, K., Kadimisetty, K., & Liu, C. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04973 · Cited by 135
Tam, P. D., Hieu, N. V., Chiến, N. Đ., Le, A., & Anh, T. M. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.08.002 · Cited by 130
Li, F., Han, X., & Liu, S. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.11.020 · Cited by 130
Stimuli-responsive polymer nano-science: Shape anisotropy, responsiveness, applications
Lu, C., & Urban, M. W. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.07.005 · Cited by 132
Multivalent ions induce lateral structural inhomogeneities in polyelectrolyte brushes
Yu, J., Jackson, N. E., Xu, X., Brettmann, B. K., Ruths, M., de Pablo, J. J., & Tirrell, M. (2017) · Science Advances · doi:10.1126/sciadv.aao1497 · Cited by 127
Solution-based circuits enable rapid and multiplexed pathogen detection
Lam, B., Das, J., Holmes, R. D., Live, L. S., Sage, A. T., Sargent, E. H., & Kelley, S. O. (2013) · Nature Communications · doi:10.1038/ncomms3001 · Cited by 136
Structure, stability and behaviour of nucleic acids in ionic liquids
Tateishi‐Karimata, H., & Sugimoto, N. (2014) · Nucleic Acids Research · doi:10.1093/nar/gku499 · Cited by 130
Ding, L., Bond, A. M., Zhai, J., & Zhang, J. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.07.035 · Cited by 138
Pandey, R., Chang, D., Smieja, M., Hoare, T. R., Li, Y., & Soleymani, L. (2021) · Nature Chemistry · doi:10.1038/s41557-021-00718-x · Cited by 128
Chemical Control of the DNA Light Switch: Cycling the Switch ON and OFF
Liu, Y., Chouai, A., Degtyareva, N. N., Lutterman, D. A., Dunbar, K. R., & Turró, C. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052648n · Cited by 128
Wagenknecht, H. (2006) · Natural Product Reports · doi:10.1039/b504754b · Cited by 140
Micro- and Nanocantilever Devices and Systems for Biomolecule Detection
Hwang, K. S., Lee, S.-M., Kim, S. K., Lee, J. H., & Kim, T. S. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155232 · Cited by 134
Electrochemical molecular analysis without nucleic acid amplification
Gau, V., Ma, S., Wang, H., Tsukuda, J., Kibler, J. L., & Haake, D. A. (2005) · Methods · doi:10.1016/j.ymeth.2005.05.008 · Cited by 130
Simulation Study of Dielectric Modulated Dual Channel Trench Gate TFET-Based Biosensor
Kumar, S., Singh, Y., Singh, B., & Tiwari, P. K. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3001300 · Cited by 130
“THERE are numerous biosensors reported in literature employing different principles of operation for biomolecule detection such as optical [1], magnetic [2], electromechanical [3], piezoelectric [4] etc.”
BackgroundZHENG, K. C., Liu, F., Xu, X., Li, Y., Wu, Z., & Yan, C. (2014) · New Journal of Chemistry · doi:10.1039/c4nj00092g · Cited by 125
Kaiser, W., & Rant, U. (2010) · Journal of the American Chemical Society · doi:10.1021/ja908727d · Cited by 124
Pan, Y., Sonn, G. A., Sin, M. L. Y., Mach, K. E., Shih, M., Gau, V., Wong, P. K., & Liao, J. C. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.002 · Cited by 135
“Electrochemical biosensors are molecular sensing devices that couple a biological recognition element to an electrode transducer (Drummond et al., 2003; Wang, 2005, 2006).”
BackgroundFerrocene‐Functionalized Cationic Polythiophene for the Label‐Free Electrochemical Detection of DNA
Floch, F. L., Ho, H. ‐., Harding‐Lepage, P., Bédard, M., Neagu‐Plesu, R., & Leclerc, M. (2005) · Advanced Materials · doi:10.1002/adma.200401474 · Cited by 123
Nucleic acid charge transfer: Black, white and gray
Venkatramani, R., Keinan, S., Balaeff, A., & Beratan, D. N. (2010) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2010.12.010 · Cited by 121
16-Channel CMOS Impedance Spectroscopy DNA Analyzer With Dual-Slope Multiplying ADCs
Jafari, H., Soleymani, L., & Genov, R. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2226334 · Cited by 122
Attomole DNA Electrochemical Sensor for the Detection of Escherichia coli O157
Liao, W., & Ho, J. A. (2009) · Analytical Chemistry · doi:10.1021/ac8020517 · Cited by 122
Collins, L. F., Jesse, S., Kilpatrick, J. I., Tselev, A., Varenyk, O. V., Okatan, M. B., Weber, S. A. L., Kumar, A., Balke, N., Kalinin, S. V., et al. (2014) · Nature Communications · doi:10.1038/ncomms4871 · Cited by 120
Microfluidic electrochemical assay for rapid detection and quantification of Escherichia coli
Safavieh, M., Ahmed, M. U., Tolba, M., & Zourob, M. M. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.11.032 · Cited by 127
Hu, J., & Zhang, C. (2010) · Analytical Chemistry · doi:10.1021/ac1019599 · Cited by 120
Water printing of ferroelectric polarization
Tian, Y. P., Wei, L., Zhang, Q., Huang, H., Zhang, Y., Zhou, H., Ma, F., Gu, L., Meng, S., Chen, L., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-06369-w · Cited by 120
Application of Electrochemical Biosensors in Clinical Diagnosis
Monošík, R., Streďanský, M., & Šturdík, E. (2012) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.20500 · Cited by 126
i-Motif Quadruplex DNA-Based Biosensor for Distinguishing Single- and Multiwalled Carbon Nanotubes
Peng, Y., Wang, X., Xiao, Y., Feng, L., Zhao, C., Ren, J., & Qu, X. (2009) · Journal of the American Chemical Society · doi:10.1021/ja9051763 · Cited by 122
Determination of endotoxin through an aptamer-based impedance biosensor
Su, W., Lin, M. S., Lee, H., Cho, M. S., Choe, W., & Lee, Y. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.11.009 · Cited by 118
“…the aptamer-based iosensors provide some advantages compared to biosensors relyng on natural receptors such as antibodies, enzymes, and peptides Drummond et al., 2003; Kim et al., 2008; Presnova et al., 2008; ong et al., 2008; Hianik and Wang, 2009; Lei et al., 2009; Sassolas t al., 2009; Xu…”
BackgroundCD-Based Microfluidics for Primary Care in Extreme Point-of-Care Settings
Smith, S., Mager, D., Perebikovsky, A., Shamloo, E., Kinahan, D. J., Mishra, R., Delgado, S. T., Kido, H., Saha, S., Ducrée, J., et al. (2016) · Micromachines · doi:10.3390/mi7020022 · Cited by 118
Beyond Simple Cartoons: Challenges in Characterizing Electrochemical Biosensor Interfaces
Bizzotto, D., Burgess, I. J., Doneux, T., Sagara, T., & Yu, H. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00840 · Cited by 118
Aptasensor and genosensor methods for detection of microbes in real world samples
Paniel, N., Baudart, J., Hayat, A., & Barthelmebs, L. (2013) · Methods · doi:10.1016/j.ymeth.2013.07.001 · Cited by 118
Fluorescence detection for DNA using hybridization chain reaction with enzyme-amplification
Niu, S., Jiang, Y., & Zhang, S. (2010) · Chemical Communications · doi:10.1039/c000166j · Cited by 118
Newton, L., Slater, T. J. A., Clark, N., & Vijayaraghavan, A. (2012) · Journal of Materials Chemistry C · doi:10.1039/c2tc00146b · Cited by 117
Aptamer‐Based Label‐Free Immunosensors Using Carbon Nanotube Field‐Effect Transistors
Maehashi, K., Matsumoto, K., Takamura, Y., & Tamiya, E. (2009) · Electroanalysis · doi:10.1002/elan.200804552 · Cited by 117
Paniel, N., Istamboulié, G., Triki, A., Lozano, C., Barthelmebs, L., & Noguer, T. (2016) · Talanta · doi:10.1016/j.talanta.2016.09.058 · Cited by 115
Jahn, S., & Kärst, U. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.05.066 · Cited by 114
Electrochemical Assay for the Signal-On Detection of Human DNA Methyltransferase Activity
Muren, N. B., & Barton, J. K. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4085918 · Cited by 113
Self-citationSuperwettable Electrochemical Biosensor toward Detection of Cancer Biomarkers
Xu, T., Song, Y., Gao, W. F., Wu, T., Xu, L., Zhang, X., & Wang, S. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00868 · Cited by 113
Electromagnetic Nanoparticles for Sensing and Medical Diagnostic Applications
Spada, L. L., & Vegni, L. (2018) · Materials · doi:10.3390/ma11040603 · Cited by 120
Sabahi, A., Salahandish, R., Ghaffarinejad, A., & Omidinia, E. (2019) · Talanta · doi:10.1016/j.talanta.2019.120595 · Cited by 119
Shiddiky, M. J. A., & Shim, Y. (2007) · Analytical Chemistry · doi:10.1021/ac0701177 · Cited by 114
Low‐Noise Stemless PNA Beacons for Sensitive DNA and RNA Detection
Socher, E. R., Bethge, L., Knoll, A., Jungnick, N., Herrmann, A., & Seitz, O. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803549 · Cited by 114
Electrochemical biosensors for food analysis
Viswanathan, S., Radecka, H., & Radecki, J. (2009) · Monatshefte für Chemie - Chemical Monthly · doi:10.1007/s00706-009-0143-5 · Cited by 115
A sensitive DNA capacitive biosensor using interdigitated electrodes
Wang, L., Veselinović, M., Yang, L., Geiss, B. J., Dandy, D. S., & Chen, T. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.006 · Cited by 113
“…modality has been used successfully to detect specific DNA molecules in complex mixtures in a number of different assays, making it attractive for reliable classification of target DNA (Boyd, 2013; Ventimiglia and Petralia, 2013; Drummond et al., 2003; Byron et al., 2016; Marzancola et al., 2016).”
BackgroundXu, Q., Yuan, H. S., Dong, X., Zhang, Y., Asif, M., Dong, Z., He, W., Ren, J., Sun, Y., & Xiao, F. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.02.026 · Cited by 113
Zhang, J., Lao, R., Song, S., Yan, Z., & Fan, C. (2008) · Analytical Chemistry · doi:10.1021/ac801424y · Cited by 120
Tiwari, I., Singh, M., Pandey, C. M., & Sumana, G. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.09.056 · Cited by 112
Recent advances in electrochemical DNA hybridization sensors
Hvastkovs, E. G., & Buttry, D. A. (2010) · The Analyst · doi:10.1039/c0an00113a · Cited by 112
Amasia, M., Cozzens, M., & Madou, M. J. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.11.080 · Cited by 112
Single‐Molecule Detection of Proteins Using Aptamer‐Functionalized Molecular Electronic Devices
Liu, S., Zhang, X., Luo, W., Wang, Z., Guo, X., Steigerwald, M. L., & Fang, X. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201006469 · Cited by 112
Electrochemical aptamer-based biosensors as potential tools for clinical diagnostics
Jarczewska, M., Górski, Ł., & Malinowska, E. (2016) · Analytical Methods · doi:10.1039/c6ay00499g · Cited by 113
Dehghani, Z., Hosseini, M., Mohammadnejad, J., Bakhshi, B., & Rezayan, A. H. (2018) · Microchimica Acta · doi:10.1007/s00604-018-2976-2 · Cited by 112
Liu, Y., Hammitt, R., Lutterman, D. A., Thummel, R. P., & Turró, C. (2007) · Inorganic Chemistry · doi:10.1021/ic700484j · Cited by 111
Electrochemical Detection of MicroRNAs via Gap Hybridization Assay
Pöhlmann, C., & Sprinzl, M. (2010) · Analytical Chemistry · doi:10.1021/ac100186p · Cited by 117
Paniel, N., & Noguer, T. (2019) · Foods · doi:10.3390/foods8090371 · Cited by 134
Han, S., Liu, W., Zheng, M., & Wang, R. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03520 · Cited by 114
Unusual Photophysical Properties of a Ruthenium(II) Complex Related to [Ru(bpy)2(dppz)]2+
Sun, Y., Collins, S. N., Joyce, L. E., & Turró, C. (2010) · Inorganic Chemistry · doi:10.1021/ic9025365 · Cited by 111
Li, D., Yan, Y., Wieckowska, A., & Willner, I. (2007) · Chemical Communications · doi:10.1039/b704731b · Cited by 110
Biosensors for the Detection of Food Pathogens
Poltronieri, P., Mezzolla, V., Primiceri, E., & Maruccio, G. (2014) · Foods · doi:10.3390/foods3030511 · Cited by 110
“, antibodies) and, when stimulated by an electrode, allow detection at very low concentrations [51].”
BackgroundDu, P., Li, H., Mei, Z., & Liu, S. (2009) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2009.01.003 · Cited by 112
E-DNA sensors for convenient, label-free electrochemical detection of hybridization
Ricci, F., & Plaxco, K. W. (2008) · Microchimica Acta · doi:10.1007/s00604-008-0015-4 · Cited by 110
Lan, T., Zhang, J., & Lu, Y. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.03.002 · Cited by 111
Towards nanoscale electrical measurements in liquid by advanced KPFM techniques: a review
Collins, L. F., Kilpatrick, J. I., Kalinin, S. V., & Rodriguez, B. J. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab560 · Cited by 117
Corbett, C.-A. L., & Tardif, F. J. (2006) · Pest Management Science · doi:10.1002/ps.1219 · Cited by 110
Luo, X., Lee, T. M. H., & Hsing, I. (2008) · Analytical Chemistry · doi:10.1021/ac8010236 · Cited by 109
Fornaro, T., Biczysko, M., Monti, S., & Barone, V. (2014) · Physical Chemistry Chemical Physics · doi:10.1039/c3cp54724h · Cited by 114
Pellitero, M. A., Shaver, A., & Arroyo‐Currás, N. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.0292003jes · Cited by 109
Sharma, P. K., Kim, E., Mishra, S., Ganbold, E., Seong, R., Kaushik, A. K., & Kim, N. (2021) · ACS Sensors · doi:10.1021/acssensors.1c01437 · Cited by 111
Paper-based devices for energy applications
Sharifi, F. J., Ghobadian, S., Cavalcanti, F. R., & Hashemi, N. N. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.08.027 · Cited by 110
“Paper-based microanalytical devices usually perform assays which require some sort of powering such as fluorescent, electrochemical [117], and electrochemiluminescent readouts [118].”
BackgroundZhang, D., Huarng, M. C., & Alocilja, E. C. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.012 · Cited by 108
Development of an Advanced Electrochemical DNA Biosensor for Bacterial Pathogen Detection
Liao, J. C., Mastali, M., Li, Y., Gau, V., Suchard, M. A., Babbitt, J. T., GORNBEIN, J. A., Landaw, E. M., McCabe, E. R. B., Churchill, B. M., et al. (2007) · Journal of Molecular Diagnostics · doi:10.2353/jmoldx.2007.060052 · Cited by 108
Role and implications of nanodiagnostics in the changing trends of clinical diagnosis
Alharbi, K. K., & Al‐Sheikh, Y. A. (2013) · Saudi Journal of Biological Sciences · doi:10.1016/j.sjbs.2013.11.001 · Cited by 111
“DNA-based electrochemical sensors offer sensitivity, selectivity and low cost for the detection of mutated genes associated with human disease (Drummond et al., 2003).”
BackgroundPhotoresponsive DNA materials and their applications
Wang, C., O’Hagan, M., Li, Z., Zhang, J., Ma, X., Tian, H., & Willner, I. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00688f · Cited by 111
Advances in nucleic acid-based diagnostics of bacterial infections
Barken, K. B., Haagensen, J. A. J., & Tolker‐Nielsen, T. (2007) · Clinica Chimica Acta · doi:10.1016/j.cca.2007.07.004 · Cited by 111
DNA-based nanobiostructured devices: The role of quasiperiodicity and correlation effects
Albuquerque, E. L., Fulco, U. L., Freire, V. N., Caetano, E. W. S., Lyra, M. L., & de Moura, F. A. B. F. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.10.004 · Cited by 109
A simple and direct electrochemical detection of interferon-γ using its RNA and DNA aptamers
Min, K., Cho, M., Han, S.-Y., Shim, Y., Ku, J., & Ban, C. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.02.021 · Cited by 111
Yang, F., Zuo, X., Li, Z., Deng, W., Shi, J., Zhang, G., Huang, Q., Song, S., & Fan, C. (2014) · Advanced Materials · doi:10.1002/adma.201400451 · Cited by 106
Extraction, amplification and detection of DNA in microfluidic chip-based assays
Wu, J., Kodzius, R., Cao, W., & Wen, W. (2013) · Microchimica Acta · doi:10.1007/s00604-013-1140-2 · Cited by 113
Hairpin-DNA Probe for Enzyme-Amplified Electrochemical Detection of Legionella pneumophila
Miranda‐Castro, R., de‐los‐Santos‐Álvarez, P., Lobo-Castañón, M. J., Miranda-Ordieres, A. J., & Tuñón‐Blanco, P. (2007) · Analytical Chemistry · doi:10.1021/ac062260q · Cited by 106
Surface chemistry effects on the performance of an electrochemical DNA sensor
Ricci, F., Zari, N., Caprio, F., Recine, S., Amine, A., Moscone, D., Palleschi, G., & Plaxco, K. W. (2009) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2009.03.007 · Cited by 106
Biosensor diagnosis of urinary tract infections: a path to better treatment?
Mach, K. E., Wong, P. K., & Liao, J. C. (2011) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2011.03.001 · Cited by 107
Potential diagnostic applications of biosensors: current and future directions
Song, S., Xu, H., & Fan, C. (2006) · International Journal of Nanomedicine · doi:10.2147/nano.2006.1.4.433 · Cited by 110
“Such a difference can be readily read out via cyclic voltammetric or coulometric assays, which forms the basis of a rapid DNA mutation screening sensor (Boon et al 2000b; Drummond et al 2003).”
Black phosphorus nanoparticles as a novel fluorescent sensing platform for nucleic acid detection
Yew, Y. T., Sofer, Z., Mayorga‐Martinez, C. C., & Pumera, M. (2017) · Materials Chemistry Frontiers · doi:10.1039/c6qm00341a · Cited by 109
Phares, N., White, R. J., & Plaxco, K. W. (2009) · Analytical Chemistry · doi:10.1021/ac8021983 · Cited by 105
Shi, W., & Ma, Z. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.072 · Cited by 103
Electroanalysis Utilizing Amperometric Microdisk Electrode Arrays
Ordeig, O., del Campo, F. J., Muñoz, F. X., Banks, C. E., & Compton, R. G. (2007) · Electroanalysis · doi:10.1002/elan.200703914 · Cited by 104
Label-Free DNA Detection on Nanostructured Ag Surfaces
Peng, H.-I., Strohsahl, C. M., Leach, K. E., Krauss, T. D., & Miller, B. L. (2009) · ACS Nano · doi:10.1021/nn900112e · Cited by 103
Optical and electrochemical DNA nanobiosensors
Dolatabadi, J. E. N., Mashinchian, O., Ayoubi, B., Jamali, A. A., Mobed, A., Lošić, D., Omidi, Y., & de la Guárdia, M. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.11.010 · Cited by 104
Electroactivity of Nonconjugated Proteins and Peptides. Towards Electroanalysis of All Proteins
Paleček, E., & Ostatná, V. (2007) · Electroanalysis · doi:10.1002/elan.200704033 · Cited by 104
Shahdeo, D., Roberts, A., Abbineni, N., & Gandhi, S. (2020) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2020.08.007 · Cited by 107
Detection of the Prostate Cancer Biomarker PCA3 with Electrochemical and Impedance-Based Biosensors
Soares, J. C., Soares, A. C., Rodrigues, V. C., Melendez, M. E., Santos, A. C., Faria, E. F., Reis, R. M., Carvalho, A. L., & Oliveira, O. N. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b19180 · Cited by 107
Label-free DNA sensors using ultrasensitive diamond field-effect transistors in solution
Song, K.-S., Zhang, G.-J., Nakamura, Y., Furukawa, K., Hiraki, T., Yang, J.-H., Funatsu, T., Ohdomari, I., & Kawarada, H. (2006) · Physical Review E · doi:10.1103/physreve.74.041919 · Cited by 104
Yang, H. S., Metera, K., & Sleiman, H. F. (2010) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2010.02.026 · Cited by 103
Stimuli-responsive monolayers for biotechnology
Nandivada, H., Ross, A. M., & Lahann, J. (2009) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.11.001 · Cited by 103
Su, X., & Hatton, T. A. (2017) · Physical Chemistry Chemical Physics · doi:10.1039/c7cp02822a · Cited by 109
Signal Amplified Gold Nanoparticles for Cancer Diagnosis on Paper-Based Analytical Devices
Huang, J., Lin, H. V., Chen, T., Chen, C., Chang, H.-T., & Chen, C. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00823 · Cited by 106
A Biosensor Platform for Rapid Antimicrobial Susceptibility Testing Directly From Clinical Samples
Mach, K. E., Mohan, R., Baron, E. J., Shih, M., Gau, V., Wong, P. K., & Liao, J. C. (2010) · The Journal of Urology · doi:10.1016/j.juro.2010.09.022 · Cited by 109
“Overall 267 101 94 16 (4) 4 (1) AMP 32 g/ml 17 41 93 3 (5) 1 (2) CIP 4 g/ml 49 22 90 7 (10) 0 (0) SXT 4/76 g/ml 45 26 96 2 (3) 1 (1) AXO 64 g/ml 56 5 98 0 (0) 1 (2) GEN 16 g/ml 65 7 94 3 (4) 1 (1) FEP 32 g/ml 35 0 97 1 (3) 0 (0) E.”
Electrochemical Detection of Single-Nucleotide Mismatches: Application of M-DNA
Long, Y., Li, C.-Z., Sutherland, T. C., Kraatz, H., & Lee, J. S. (2004) · Analytical Chemistry · doi:10.1021/ac049482d · Cited by 103
Metadata
- Authors
- Drummond, T. G., Hill, M. G., & Barton, J. K.
- Affiliations
- California Institute of Technology (US)
- Occidental College (US)
- Corresponding author
- Barton, Jacqueline K
- Venue
- Nature Biotechnology
- Published
- 2003-10
- Volume
- 21
- Issue
- 10
- Pages
- 1192-1199
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2009040055
- Cited by
- 2,214
- References
- 57
- Citations by year
- 2026: 33 · 2025: 47 · 2024: 47 · 2023: 73 · 2022: 69 · 2021: 73 · 2020: 82 · 2019: 79 · 2018: 98 · 2017: 94 · 2016: 113 · 2015: 143 · 2014: 151 · 2013: 138 · 2012: 117
- FWCI
- 5.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- National Institutes of Health
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- electrochemical DNA biosensor, DNA detection, gene mutation detection, polymer-modified electrodes, redox reporter, nanoparticles, DNA-mediated charge transport
- MeSH terms
- DNA, Electrochemistry, Equipment Design, Membranes, Artificial, Proteins, Transducers, Biosensing Techniques, Coated Materials, Biocompatible, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.