The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Fast live-cell conventional fluorophore nanoscopy with ImageJ through super-resolution radial fluctuations
Open accessAbstract
Despite significant progress, high-speed live-cell super-resolution studies remain limited to specialized optical setups, generally requiring intense phototoxic illumination. Here, we describe a new analytical approach, super-resolution radial fluctuations (SRRF), provided as a fast graphics processing unit-enabled ImageJ plugin. In the most challenging data sets for super-resolution, such as those obtained in low-illumination live-cell imaging with GFP, we show that SRRF is generally capable of achieving resolutions better than 150 nm. Meanwhile, for data sets similar to those obtained in PALM or STORM imaging, SRRF achieves resolutions approaching those of standard single-molecule localization analysis. The broad applicability of SRRF and its performance at low signal-to-noise ratios allows super-resolution using modern widefield, confocal or TIRF microscopes with illumination orders of magnitude lower than methods such as PALM, STORM or STED. We demonstrate this by super-resolution live-cell imaging over timescales ranging from minutes to hours.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890
Super-resolution fluorescence microscopy
Huang, B., Bates, M., & Zhuang, X. (2009) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.061906.092014 · Cited by 1,657
Cited by
Transcription activation is enhanced by multivalent interactions independent of phase separation
Trojanowski, J., Frank, L., Rademacher, A., Mücke, N., Grigaitis, P., & Rippe, K. (2022) · Molecular Cell · doi:10.1016/j.molcel.2022.04.017 · Cited by 232
Seeing beyond the limit: A guide to choosing the right super-resolution microscopy technique
Valli, J., Garcia-Burgos, A., Rooney, L. M., Vale de Melo e Oliveira, B., Duncan, R. R., & Rickman, C. (2021) · Journal of Biological Chemistry · doi:10.1016/j.jbc.2021.100791 · Cited by 159
Oligodendrocytes express synaptic proteins that modulate myelin sheath formation
Hughes, A. N., & Appel, B. (2019) · Nature Communications · doi:10.1038/s41467-019-12059-y · Cited by 128
One-step nanoscale expansion microscopy reveals individual protein shapes
Shaib, A. H., Chouaib, A. A., Chowdhury, R., Altendorf, J., Mihaylov, D., Zhang, C., Krah, D., Imani, V., Spencer, R. K. W., Georgiev, S. V., et al. (2025) · Nature Biotechnology · doi:10.1038/s41587-024-02431-9 · Cited by 104
Inbred or Outbred? Genetic Diversity in Laboratory Rodent Colonies
Brekke, T. D., Steele, K. A., & Mulley, J. F. (2018) · G3 Genes|Genomes|Genetics · doi:10.1534/g3.117.300495 · Cited by 67
Metadata
- Authors
- Gustafsson, N., Culley, S., Ashdown, G., Owen, D. M., Pereira, P. M., & Henriques, R.
- Venue
- Nature Communications
- Published
- 2016-08-12
- Volume
- 7
- Issue
- 1
- Pages
- 12471-12471
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2512505748
- Cited by
- 626
- References
- 2
- FWCI
- 26.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fast live-cell conventional fluorophore nanoscopy with ImageJ through super-resolution radial fluctuations. https://app.cochat.ai/papers/10.1038/ncomms12471
- The paper
- Gustafsson, N., Culley, S., Ashdown, G., Owen, D. M., Pereira, P. M., & Henriques, R. (2016). Fast live-cell conventional fluorophore nanoscopy with ImageJ through super-resolution radial fluctuations. Nature Communications. https://doi.org/10.1038/ncomms12471
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.