CoChat

Flexible and self-powered temperature–pressure dual-parameter sensors using microstructure-frame-supported organic thermoelectric materials

Open access

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

Skin-like temperature- and pressure-sensing capabilities are essential features for the next generation of artificial intelligent products. Previous studies of e-skin and smart elements have focused on flexible pressure sensors, whereas the simultaneous and sensitive detection of temperature and pressure with a single device remains a challenge. Here we report developing flexible dual-parameter temperature–pressure sensors based on microstructure-frame-supported organic thermoelectric (MFSOTE) materials. The effective transduction of temperature and pressure stimuli into two independent electrical signals permits the instantaneous sensing of temperature and pressure with an accurate temperature resolution of <0.1 K and a high-pressure-sensing sensitivity of up to 28.9 kPa−1. More importantly, these dual-parameter sensors can be self-powered with outstanding sensing performance. The excellent sensing properties of MFSOTE-based devices, together with their unique advantages of low cost and large-area fabrication, make MFSOTE materials possess promising applications in e-skin and health-monitoring elements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ncomms9356

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Illustrative schematic and electrical properties of MFSOTE devices. (a–h) Schematic illustration of temperature–pressure (T–P) sensing mechanism: (a,b) pristine. (c,d) a temperature gradient (ΔT) is applied across a MFSOTE device. (e,f) a pressure is loaded. (g,h) loading of a coupled temperature and pressure stimuli. Graph (i,j) show the measured I–V curves of a MFSOTE device taken at various ΔT (i) and different loading pressure (j). The time delay (i,j) between the contact and the measurement of the electrical signal is 10 s.
Figure 1 Illustrative schematic and electrical properties of MFSOTE devices. (a–h) Schematic illustration of temperature–pressure (T–P) sensing mechanism: (a,b) pristine. (c,d) a temperature gradient (ΔT) is applied across a MFSOTE device. (e,f) a pressure is loaded. (g,h) loading of a coupled temperature and pressure stimuli. Graph (i,j) show the measured I–V curves of a MFSOTE device taken at various ΔT (i) and different loading pressure (j). The time delay (i,j) between the contact and the measurement of the electrical signal is 10 s.CC BY · PubMed Central
Figure 2 Electrical characterization of MFSOTE devices. (a) Output voltage of a MFSOTE device to a biased temperature gradient range of 0−100 K. The insert shows the magnified response signal of a MFSOTE device to a temperature gradient of 0.1 K. (b) Measured output voltage as a function of temperature gradient. (c) Current response of a MFSOTE device to various pressures at a constant voltage of 0.1 V. The insert shows the magnified response signal to the pressure of 100 Pa. (d) Current responses of the MFSOTE devices to various pressures. The error bars in graph (b,d) represent the s.d. (e) Time-resolved responses of a MFSOTE device to temperature and pressure stimuli. The pink and the grey zones represent the response and relaxation time, respectively. (f) The durability test of a MFSOTE device under a pressure of 1 kPa.
Figure 2 Electrical characterization of MFSOTE devices. (a) Output voltage of a MFSOTE device to a biased temperature gradient range of 0−100 K. The insert shows the magnified response signal of a MFSOTE device to a temperature gradient of 0.1 K. (b) Measured output voltage as a function of temperature gradient. (c) Current response of a MFSOTE device to various pressures at a constant voltage of 0.1 V. The insert shows the magnified response signal to the pressure of 100 Pa. (d) Current responses of the MFSOTE devices to various pressures. The error bars in graph (b,d) represent the s.d. (e) Time-resolved responses of a MFSOTE device to temperature and pressure stimuli. The pink and the grey zones represent the response and relaxation time, respectively. (f) The durability test of a MFSOTE device under a pressure of 1 kPa.CC BY · PubMed Central
Figure 3 Self-powered sensing performance of MFSOTE devices. (a) Current response of a self-powered MFSOTE sensor to a pressure of 1 kPa taken under various temperature differences (0, 1, 5 and 10 K). (b) Pressure response of current changes driven by various temperature gradients. The error bars represent the s.d. (c,d) Plots showing the current and output voltage responses of a self-powered MFSOTE sensor to loading–unloading cycles of (c) a constant pressure of 5 kPa and (d) finger touch. The sensing temperature on the top surface is calculated by TS=Vtherm/ST+T0, where T0 is the ambient temperature (25.0 °C).
Figure 3 Self-powered sensing performance of MFSOTE devices. (a) Current response of a self-powered MFSOTE sensor to a pressure of 1 kPa taken under various temperature differences (0, 1, 5 and 10 K). (b) Pressure response of current changes driven by various temperature gradients. The error bars represent the s.d. (c,d) Plots showing the current and output voltage responses of a self-powered MFSOTE sensor to loading–unloading cycles of (c) a constant pressure of 5 kPa and (d) finger touch. The sensing temperature on the top surface is calculated by TS=Vtherm/ST+T0, where T0 is the ambient temperature (25.0 °C).CC BY · PubMed Central
Figure 4 Real-time monitoring of temperature and pressure. (a,c,e,g) Schematic diagram and (b,d,f,h) infrared thermal images of a MFSOTE device approached by a Peltier element (27 °C). The temperature distribution was recorded simultaneously using a FLIR A300. The arrow indicates the moving direction of the Peltier element. (i) Plots of the real-time output voltage and current responses of a MFSOTE device approached by a Peltier element (27 °C).
Figure 4 Real-time monitoring of temperature and pressure. (a,c,e,g) Schematic diagram and (b,d,f,h) infrared thermal images of a MFSOTE device approached by a Peltier element (27 °C). The temperature distribution was recorded simultaneously using a FLIR A300. The arrow indicates the moving direction of the Peltier element. (i) Plots of the real-time output voltage and current responses of a MFSOTE device approached by a Peltier element (27 °C).CC BY · PubMed Central
Figure 5 Multifunctional application of MFSOTE-based-sensing array. Graphs (a,b) show a photograph and circuit diagram, respectively, of an MFSOTE array with 4 × 4 pixels. Graphs (c,d) show schematic illustrations of the integrated array: (c) All the devices connected in series can be used as an electricity generator for harvesting energy. (d) The device switches to a self-powered dual-parameter sensor model when subjected to an external pressure. The insets in graph (c,d) show magnified views of the circuit connection between two pixels under unloading and loading conditions, respectively. (e) The thermoelectric voltage (top), temperature (middle), and pressure (bottom) responses of a MFSOTE array to five finger-touch cycles. The bottom surface of the MFSOTE array is heated with a Peltier element.
Figure 5 Multifunctional application of MFSOTE-based-sensing array. Graphs (a,b) show a photograph and circuit diagram, respectively, of an MFSOTE array with 4 × 4 pixels. Graphs (c,d) show schematic illustrations of the integrated array: (c) All the devices connected in series can be used as an electricity generator for harvesting energy. (d) The device switches to a self-powered dual-parameter sensor model when subjected to an external pressure. The insets in graph (c,d) show magnified views of the circuit connection between two pixels under unloading and loading conditions, respectively. (e) The thermoelectric voltage (top), temperature (middle), and pressure (bottom) responses of a MFSOTE array to five finger-touch cycles. The bottom surface of the MFSOTE array is heated with a Peltier element.CC BY · PubMed Central
Figure 6 Photographs and performance of flexible MFSOTE matrixes. (a) Photograph of a prosthetic hand arm-wrestling with an adult woman. Graph (b) displays the temperature and pressure mapping profiles of pixel signals on the back of the prosthetic hand. Graph (c) shows an e-finger touching an ice cube. The inset shows the optical microscope image of the inkjet-printed MFSOTE matrix. Scale bar, 1 mm. (d) Photograph temperature and pressure mappings of the sensing array.
Figure 6 Photographs and performance of flexible MFSOTE matrixes. (a) Photograph of a prosthetic hand arm-wrestling with an adult woman. Graph (b) displays the temperature and pressure mapping profiles of pixel signals on the back of the prosthetic hand. Graph (c) shows an e-finger touching an ice cube. The inset shows the optical microscope image of the inkjet-printed MFSOTE matrix. Scale bar, 1 mm. (d) Photograph temperature and pressure mappings of the sensing array.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Cited by

Items 501–600 of 667

Metadata

Authors
Zhang, F., Zang, Y., Huang, D., Di, C.-A., & Zhu, D.
Affiliations
Chinese Academy of Sciences (CN)
Corresponding author
  • Di, Chong-an
  • Zhu, Daoben
Venue
Nature Communications
Published
2015-09-21
Volume
6
Issue
1
Pages
8356-8356
ISSN
2041-1723 (ISSN-L)
OpenAlex
W2147820879
Cited by
668
References
42
Citations by year
2026: 44 · 2025: 78 · 2024: 74 · 2023: 75 · 2022: 75 · 2021: 82 · 2020: 63 · 2019: 69 · 2018: 45 · 2017: 44 · 2016: 19
FWCI
17.91
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Funders
Chinese Academy of Sciences (XDB12010000)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Materials Chemistry › Advanced Thermoelectric Materials and Devices
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
Keywords
organic thermoelectrics, flexible sensors, self-powered sensors, electronic skin, pressure sensing, health monitoring, wearable electronics
MeSH terms
Biocompatible Materials, Equipment Design, Pressure, Skin, Temperature, Transistors, Electronic, Skin, Artificial

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.