Noninvasive electrocardiographic imaging for cardiac electrophysiology and arrhythmia
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Over 7 million people worldwide die annually from erratic heart rhythms (cardiac arrhythmias), and many more are disabled. Yet there is no imaging modality to identify patients at risk, provide accurate diagnosis and guide therapy. Standard diagnostic techniques such as the electrocardiogram (ECG) provide only low-resolution projections of cardiac electrical activity on the body surface. Here we demonstrate the successful application in humans of a new imaging modality called electrocardiographic imaging (ECGI), which noninvasively images cardiac electrical activity in the heart. In ECGI, a multielectrode vest records 224 body-surface electrocardiograms; electrical potentials, electrograms and isochrones are then reconstructed on the heart's surface using geometrical information from computed tomography (CT) and a mathematical algorithm. We provide examples of ECGI application during atrial and ventricular activation and ventricular repolarization in (i) normal heart (ii) heart with a conduction disorder (right bundle branch block) (iii) focal activation initiated by right or left ventricular pacing, and (iv) atrial flutter.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“BSPM has nowadays got a real clinical breakthrough as a method for non-invasive 3D EAI, with the competitive concept of “ECG imaging” (ECGi) (239–241), a technology that has rapidly evolved in clinically available devices (242), increasingly used for non-invasive pre-interventional assessment of patients undergoing catheter ablation procedures (243, 244).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [239]
Citations
Cites
Solutions of Ill-Posed Problems.
Bell, J. B., Tikhonov, A. N., & Arsenin, V. Y. (1978) · Mathematics of Computation · doi:10.2307/2006360 · Cited by 8,101
Total Excitation of the Isolated Human Heart
DURRER, D., VAN DAM, R. T., FREUD, G. E., JANSE, M. J., MEIJLER, F. L., & ARZBAECHER, R. C. (1970) · Circulation · doi:10.1161/01.cir.41.6.899 · Cited by 1,777
Janse, M. J., & Wit, A. L. (1989) · Physiological Reviews · doi:10.1152/physrev.1989.69.4.1049 · Cited by 1,018
Haws, C. W., & Lux, R. L. (1990) · Circulation · doi:10.1161/01.cir.81.1.281 · Cited by 397
Ionic Current Basis of Electrocardiographic Waveforms: A Model Study
Gima, K., & Rudy, Y. (2002) · Circulation Research · doi:10.1161/01.res.0000016960.61087.86 · Cited by 396 · cited 1×
“Normal repolarization potential patterns have no direct relationship to depolarization patterns because the T-wave is determined mostly by local intrinsic repolarization propertie”
BackgroundSelf-citationSOSA, E., SCANAVACCA, M., D'AVILA, A., PICCIONI, J., SANCHEZ, O., VELARDE, J. L., SILVA, M., & REOLÃO, B. (1998) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1998.tb00907.x · Cited by 330 · cited 1×
“More than a third of clinical ventricular tachycardia cases involve the subepicardium, an observation that led to the development of transthoracic epicardial ablation to treat ventricular tachycardi”
BackgroundOster, H. S., Taccardi, B., Lux, R. L., Ershler, P. R., & Rudy, Y. (1997) · Circulation · doi:10.1161/01.cir.96.3.1012 · Cited by 256
Self-citationOster, H. S., TACCARDI, B., Lux, R. L., Ershler, P. R., & Rudy, Y. (1998) · Circulation · doi:10.1161/01.cir.97.15.1496 · Cited by 140
Self-citationEpicardial activation of the intact human heart without conduction defect.
Wyndham, C. R. C., Meeran, M. K., Smith, T., Saxena, A., Engelman, R. M., Levitsky, S., & Rosen, K. M. (1979) · Circulation · doi:10.1161/01.cir.59.1.161 · Cited by 127
A Noninvasive Imaging Modality for Cardiac Arrhythmias
Burnes, J. E., TACCARDI, B., & Rudy, Y. (2000) · Circulation · doi:10.1161/01.cir.102.17.2152 · Cited by 125
Self-citation
Research works printed but not linked: 1
- Biermann, M. et al. The interpretation of cardiac electrograms. in Cardiac Mapping (eds. Shenasa, M., Borggrefe, M. & Breithardt, G.) 15–39 (Futura Publishing, Mount Kisco, New York, 2003).
Cited by
Items 101–200 of 659
Salinet, J. L., Molero, R., Schlindwein, F. S., Karel, J. M. H., Rodrigo, M., Rojo‐Álvarez, J. L., Berenfeld, O., Climent, A. M., Zenger, B., Vanheusden, F. J., et al. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.653013 · Cited by 56
Xi, Q., Fu, Z., Wu, W., Wang, H., & Wang, Y. (2020) · Applied Mathematics and Computation · doi:10.1016/j.amc.2020.125604 · Cited by 58
Zhu, T. G., Patel, C. A., Martin, S., Quan, X., Wu, Y., Burke, J. F., Chernick, M., Kowey, P. R., & Yan, G.-X. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn585 · Cited by 54
“Normal pump function of the heart depends not only on the excitation–contraction coupling at the cellular level, but also on correct spread of electrical excitation to coordinate heart muscles as a syncytium.(1,2) Propagation of electrical impulses can be detected and recorded on the body surface electrocardiogram”
BackgroundNoninvasive epicardial and endocardial mapping of premature ventricular contractions
Wissner, E., Revishvili, A., Metzner, A., Tsyganov, A., Kalinin, V., Lemes, C., Saguner, A. M., Maurer, T., Deiss, S., Sopov, O., et al. (2016) · Europace · doi:10.1093/europace/euw103 · Cited by 52
“– 8 The method of non-invasive electrocardiographic imaging (ECGI) has demonstrated significant clinical relevance, allowing non-invasive reconstruction of local unipolar electrograms (EG) on the epicardial surface of the heart.(5) Advanced processing of reconstructed EG provides information on the cardiac activation…”
Images as drivers of progress in cardiac computational modelling
Lamata, P., Casero, R., Carapella, V., Niederer, S., Bishop, M. J., Schneider, J. E., Köhl, P., & Grau, V. (2014) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2014.08.005 · Cited by 60
“heart's surface (Ramanathan et al., 2004).”
MethodChronic ventricular pacing in children: toward prevention of pacing-induced heart disease
van Geldorp, I. E., Vanagt, W. Y. R., Prinzen, F. W., & Delhaas, T. (2010) · Heart Failure Reviews · doi:10.1007/s10741-010-9207-1 · Cited by 52
“A better approach in this respect may be the use of ECG imaging, which noninvasively images electrical activation patterns [69, 70], although the optimal activation pattern for the diverse anatomical substrates is not known yet.”
BackgroundOrini, M., Graham, A. J., Martinez–Naharro, A., Andrews, C. M., de Marvao, A., Statton, B. K., Cook, S. A., O’Regan, D. P., Hawkins, P. N., Rudy, Y., et al. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.119.012097 · Cited by 52
“15,20 Brie fl y, 256 electrodes were placed to uniformly cover the patient ’ s torso (ActiveTwo, BioSemi, Santiago, Chile), and body surface potentials were recorded at a sampling frequency of 2048 Hz for 5 minutes at rest in a supine position.”
Self-citationCorrado, C., Gerbeau, J.-F., & Moireau, P. (2014) · Journal of Computational Physics · doi:10.1016/j.jcp.2014.11.041 · Cited by 53
“…compared – in term of estimation robustness and accuracy versus difficulty– to existing methods such as electrocardiographic imaging (ECGI) [52] where only ECG-like measurements are necessary with special vests recording up to 224 body-surface potentials. where [ I [ ∗ ] ] is the matrix…”
The Electrophysiological Substrate of Early Repolarization Syndrome
Zhang, J., Hocini, M., Ström, M., Cuculich, P. S., Cooper, D. H., Sacher, F., Haïssaguerre, M., & Rudy, Y. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2016.12.017 · Cited by 57
Self-citationCrozier, A., Blazevic, B., Lamata, P., Plank, G., Ginks, M., Duckett, S. G., Sohal, M., Shetty, A., Rinaldi, C. A., Razavi, R., et al. (2015) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2015.10.026 · Cited by 50
“Sinus rhythm (SR) activation was simulated by applying a stimulus current at the earliest sites of activation in the septum and RV as determined from ECG and EnSite™ non-contact mapping (NCM) data, and from the literature [23] in the case of the location of the earliest activation in the RV.”
MethodInfluentialCakulev, I. T., Sahadevan, J., Arruda, M., Goldstein, R. N., Hong, M., Intini, A., Mackall, J. A., Stambler, B. S., Ramanathan, C., Jia, P., et al. (2012) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.112.975813 · Cited by 50
“With the vest in position, all patients underwent a thoracic computed tomographic (CT) scan to obtain the precise anatomic relation between the cardiac geometry and the torso electrodes, which were used to reconstruct 1500 unipolar electrograms on the epicardial surface of the heart.(1,2,8,9) The system also computed…”
MethodSelf-citationSakata, K., Okuyama, Y., Ozawa, T., Haraguchi, R., Nakazawa, K., Tsuchiya, T., Horie, M., & Ashihara, T. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12036 · Cited by 50
Body Surface Potential Mapping: Contemporary Applications and Future Perspectives
Bergquist, J., Rupp, L., Zenger, B., Brundage, J., Busatto, A., & MacLeod, R. (2021) · Hearts · doi:10.3390/hearts2040040 · Cited by 50
“Following a 20 year series of groundbreaking validation studies in animals [51–58] and then in humans [59,60], ECGI has been applied to explore ischemia and myocardial infarction [61], dispersion of repolarization [49], localization and characterization of ventricular [62–65] and atrial arrhythmias [66–68], and the ef…”
MethodVarma, N., Jia, P., & Rudy, Y. (2007) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2007.06.017 · Cited by 50
Self-citationComputing Ischemic Regions in the Heart With the Bidomain Model—First Steps Towards Validation
Nielsen, B. F., Lysaker, M., & Grøttum, P. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2254123 · Cited by 48
“Clinically, these methods have been used to assess activation patterns during arrhythmias [33], [34], [36], activation patterns in CRT-treated congestive heart failure [35], and the location of infarct-related myocardial scars [37].”
MethodBerger, T., Pfeifer, B. E., Hanser, F., Hintringer, F., Fischer, G., Netzer, M., Trieb, T., Stuehlinger, M., Dichtl, W., Baumgärtner, C., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016255 · Cited by 48
“Up to date, considerable efforts have been undertaken to solve the inverse problem of electrocardiography to localize and image cardiac activation sequences from body surface electrocardiograms [15,16,17].”
BackgroundStenroos, M., & Haueisen, J. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923913 · Cited by 48
A Brief History of Tissue Models For Cardiac Electrophysiology
Henriquez, C. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2310515 · Cited by 54
Wang, Y., Cuculich, P. S., Woodard, P. K., Lindsay, B. D., & Rudy, Y. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.014 · Cited by 48
Self-citationMechanistic Approaches to Detect, Target, and Ablate the Drivers of Atrial Fibrillation
Quintanilla, J. G., Pérez‐Villacastín, J., Pérez‐Castellano, N., Pandit, S. V., Berenfeld, O., Jalife, J., & Rama, D. F. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.002481 · Cited by 47
“inverse problem to noninvasively obtain estimated epicardial electrograms.(45,46) The main advantage of this approach is that it is nonin-”
BackgroundMethodNoninvasive electromechanical wave imaging and conduction-relevant velocity estimation in vivo
Konofagou, E. E., Luo, J., Saluja, D. S., Cervantes, D. O., Coromilas, J., & Fujikura, K. (2009) · Ultrasonics · doi:10.1016/j.ultras.2009.09.026 · Cited by 46
“The only methods currently available for conduction mapping in vivo involve the use of contact electrode arrays, either by mounting an electrode sock around the heart through open-heart surgery [2,3] or reconstruction from body surface potentials [4] to map the epicardial activation or, using a balloon electrode cathe…”
Physiologic Cardiovascular Strain and Intrinsic Wave Imaging
Konofagou, E. E., Lee, W.-N., Luo, J., Provost, J., & Vappou, J. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124721 · Cited by 45
“The only methods currently available for conduction mapping in vivo involve (a) the use of invasively inserted electrode arrays, by mounting an electrode sock around the heart through open-heart surgery (71, 72), (b) reconstruction from body surface potentials (73) to map the epicardial activation, or (c) the use of a…”
MethodÖzsoy, Ç., Özbek, A., Reiss, M., Deán‐Ben, X. L., & Razansky, D. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2103979118 · Cited by 46
Noninvasive electrocardiographic imaging (ECGI) of scar-related atypical atrial flutter
Wang, Y., Schuessler, R. B., Damiano, R. J., Woodard, P. K., & Rudy, Y. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.08.019 · Cited by 45
Self-citationWavefront-based models for inverse electrocardiography
Ghodrati, A., Brooks, D. H., Tadmor, G., & MacLeod, R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.878117 · Cited by 44
“Recent reports indicate great potential for this imaging modality to be used in clinical practice for cardiac electrophysiology and arrhythmias [1], [2].”
BackgroundNoninvasive ECG imaging (ECGI): Mapping the arrhythmic substrate of the human heart
Rudy, Y. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.02.104 · Cited by 43
Self-citationSilva, J. N. A., Ghosh, S., Bowman, T. M., Rhee, E. K., Woodard, P. K., & Rudy, Y. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.017 · Cited by 43
Self-citationLee, P., Calvo, C. J., Alfonso-Almazán, J. M., Quintanilla, J. G., Chorro, F. J., Yan, P., Loew, L. M., Rama, D. F., & Millet, J. (2017) · Scientific Reports · doi:10.1038/srep43217 · Cited by 42
The physics of heart rhythm disorders
Rappel, W. (2022) · Physics Reports · doi:10.1016/j.physrep.2022.06.003 · Cited by 42
Konofagou, E. E., & Provost, J. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.11.027 · Cited by 42
“Although noninvasive approaches under development such as electrocardiographic imaging have shown highly detailed three-dimensional images of the electrical activation sequence in humans (Ramanathan et al., 2004; Zhang et al., 2005), imaging cardiac electrophysiology remains a challenging problem.”
MethodCamps, J., Wang, Z. J., Doste, R., Berg, L. A., Holmes, M., Lawson, B., Tomek, J., Burrage, K., Bueno‐Orovio, A., & Rodríguez, B. (2024) · Medical Image Analysis · doi:10.1016/j.media.2024.103361 · Cited by 48
Novel approaches to mechanism-based atrial fibrillation ablation
Quintanilla, J. G., Shpun, S., Jalife, J., & Rama, D. F. (2021) · Cardiovascular Research · doi:10.1093/cvr/cvab108 · Cited by 40
Machine Learning Approaches in Diagnosis, Prognosis and Treatment Selection of Cardiac Amyloidosis
Allegra, A., Mirabile, G., Tonacci, A., Genovese, S., Pioggia, G., & Gangemi, S. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24065680 · Cited by 39
“However, only around 25% of patients had both a low ECG voltage and a pseudo-infarct pattern [62].”
BackgroundChallenges Facing Validation of Noninvasive Electrical Imaging of the Heart
Nash, M. P., & Pullan, A. J. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.00608.x · Cited by 39
Noninvasive imaging of cardiac electrophysiology and arrhythmia
Rudy, Y. (2010) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2009.05103.x · Cited by 40
Self-citationXu, J., Rahimi, A., Gao, F., & Wang, L. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2324900 · Cited by 37
“In exchange for a unique solution, a common assumption in existing approaches to electrophysiological imaging restricts the solutions to the surface of the heart, represented by the reconstruction of epicardial potential [7], [8] and the reconstruction of activation/recovery time on both the epicardium and endocardium…”
BackgroundResultAutomated ECG Interpretation—A Brief History from High Expectations to Deepest Networks
Macfarlane, P. W., & Kennedy, J. (2021) · Hearts · doi:10.3390/hearts2040034 · Cited by 41
Varma, N. (2014) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2014.09.002 · Cited by 37
“This single view visualizes most of the LV free wall, and the 30 ms threshold represents ~50% of normal LV activation time [9].”
BackgroundBrownstein, J. M., Afzal, M. R., Okabe, T., Harfi, T. T., Tong, M., Thomas, E., Hugo, G. D., Cuculich, P. S., Robinson, C. G., & Williams, T. M. (2021) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2021.03.051 · Cited by 36
Sensor Developments for Electrophysiological Monitoring in Healthcare
Prance, H. (2011) · InTech eBooks · doi:10.5772/22958 · Cited by 41
“Large element arrays for electrocardiographic imaging, for example over 200 electrodes, have been developed (Ramanathan et al., 2004; Rosik et al., 2007).”
MethodJiang, M., Xia, L., Shou, G., & Tang, M. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/5/005 · Cited by 36
Solving the Inverse Problem of Electrocardiography on the Endocardium Using a Single Layer Source
Kalinin, A. V., Potyagaylo, D., & Kalinin, V. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00058 · Cited by 35
“Non-invasive electrocardiographic imaging (ECGI) is a novel imaging modality which is based on numerical reconstruction of cardiac electrical activity using the so-called body surface potential maps (BSPM) and patient-specific heart and torso geometries (Ramanathan et al., 2004).”
MethodBond, R., Finlay, D., Nugent, C., Moore, G., & Guldenring, D. (2013) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2013.01.008 · Cited by 35
The surgical treatment of atrial fibrillation
Shen, J., Bailey, M. S., & Damiano, R. J. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.05.019 · Cited by 40
Study on Parameter Optimization for Support Vector Regression in Solving the Inverse ECG Problem
Jiang, M., Jiang, S., Zhu, L., Wang, Y., Huang, W., & Zhang, H. (2013) · Computational and Mathematical Methods in Medicine · doi:10.1155/2013/158056 · Cited by 34
“The inverse ECG problem is to obtain myocardial trans-membrane potential (TMPs) distribution from body surface potentials (BSPs), thus noninvasively imaging the electro-physiological information on the cardiac surface [1, 2].”
BackgroundLiu, C., Skadsberg, N. D., Ahlberg, S. E., Swingen, C., Iaizzo, P. A., & He, B. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.01066.x · Cited by 34
Yao, B., & Yang, H. Y. (2016) · Scientific Reports · doi:10.1038/srep39012 · Cited by 34
Berthon, B., Dansette, P.-M., Tanter, M., Pernot, M., & Provost, J. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa6ee7 · Cited by 34
Cardiac Anisotropy: Is it Negligible Regarding Noninvasive Activation Time Imaging?
Modre, R., Seger, M., Fischer, G., Hintermüller, C., Hayn, D., Pfeifer, B. E., Hanser, F., Schreier, G., & TILG, B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870253 · Cited by 34
“Coupling of ECG mapping data with 3D anatomical information from an individual patient enables noninvasive imaging of the electrical function in the heart [15], [16], [ 29 ], [30].”
MethodGhosh, S., Avari, J. N., Rhee, E. K., Woodard, P. K., & Rudy, Y. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01203.x · Cited by 34
Self-citation4D cardiac electromechanical activation imaging
Grondin, J., Wang, D., Grubb, C. S., Trayanova, N. A., & Konofagou, E. E. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103382 · Cited by 33
Noninvasive localization of cardiac arrhythmias using electromechanical wave imaging
Grubb, C. S., Melki, L., Wang, D. Y., Peacock, J. R., Dizon, J. M., Iyer, V., Sorbera, C. A., BIVIANO, A. B., Rubin, D. A., Morrow, J., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aax6111 · Cited by 35
Nademanee, K., Veerakul, G., Nogami, A., Lou, Q., Hocini, M., Coronel, R., Behr, E. R., Wilde, A. A. M., Boukens, B. J., & Haïssaguerre, M. (2021) · Heart Rhythm · doi:10.1016/j.hrthm.2021.10.031 · Cited by 33
Elliott, M. K., Strocchi, M., Sieniewicz, B., Sidhu, B. S., Mehta, V. S., Wijesuriya, N., Behar, J. M., Thorpe, A., Martic, D., Wong, T., et al. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.10.019 · Cited by 33
Harland, C. J., Clark, T. D., Peters, N. S., Everitt, M. J., & Stiffell, P. B. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/6/005 · Cited by 33
Benson, A. P., Bernus, O., Dierckx, H., Gilbert, S., Greenwood, J. P., Holden, A. V., Mohee, K., Plein, S., Radjenovic, A., Ries, M. E., et al. (2010) · Interface Focus · doi:10.1098/rsfs.2010.0005 · Cited by 36
Ravelli, F., & Masè, M. (2014) · EP Europace · doi:10.1093/europace/eut376 · Cited by 33
Electrocardiographic Imaging of Heart Rhythm Disorders
Rudy, Y., & Lindsay, B. D. (2014) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2014.11.013 · Cited by 32
Self-citationBoukens, B. J., Benjacholamas, V., van Amersfoort, S., Meijborg, V. M. F., Schumacher, C. A., Jensen, B. K., Haïssaguerre, M., Wilde, A. A. M., Prechawat, S., Huntrakul, A., et al. (2020) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2020.06.027 · Cited by 32
Ghosh, S., Avari, J. N., Rhee, E. K., Woodard, P. K., & Rudy, Y. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.03.011 · Cited by 32
Self-citationWu, W., Wang, H., Zhao, P., Talcott, M., Lai, S., McKinstry, R. C., Woodard, P. K., Macones, G. A., Schwartz, A. L., Cahill, A. G., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aau1428 · Cited by 34
Villongco, C., Krummen, D. E., Stark, P., Omens, J. H., & McCulloch, A. D. (2014) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2014.06.011 · Cited by 32
“ECGI and NICE methods have been successfully applied to a range of physiologic conditions including normal sinus rhythm, ventricular pacing, atrial flutter, ventricular tachycardia, bundle branch block (Ramanathan et al., 2004), and WolffParkinson-White syndrome (Berger et al., 2006).”
Solving the Inverse Problem of Electrocardiography for Cardiac Digital Twins: A Survey
Li, L., Camps, J., Rodríguez, B., & Grau, V. (2024) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2024.3486439 · Cited by 51
“For example, the Tikhonov regularization, including both zero-order and first-order variants, is the most widely used regularization technique [25], [50], [59]–[62].”
InfluentialBody Surface Mapping to Guide Atrial Fibrillation Ablation
Yamashita, S., Shah, A. J., Mahida, S., Sellal, J., Berte, B., Hooks, D. A., Frontera, A., Jefairix, N. A., Wielandts, J., Lim, H. S., et al. (2015) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2015.4.3.172 · Cited by 32
Machine learning-derived electrocardiographic algorithm for the detection of cardiac amyloidosis
Schrutka, L., Anner, P., Agibetov, A., Seirer, B., Dusik, F., Rettl, R., Duca, F., Dalos, D., Dachs, T.-M., Binder, C., et al. (2021) · Heart · doi:10.1136/heartjnl-2021-319846 · Cited by 33
“7 Using ECGI, the aim of the present study was to obtain electro-cardiographic maps of patients with CA.”
Engels, E. B., Mafi-Rad, M., van Stipdonk, A. M. W., Vernooy, K., & Prinzen, F. W. (2016) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-016-9693-1 · Cited by 33
“The body-surface electrical data and the anatomical data are then processed with algorithms to construct epicardial depolarization and repolarization patterns, using a single heartbeat [54].”
BackgroundMethodExperimental Validation of Noninvasive Epicardial and Endocardial Activation Imaging
Oosterhoff, P., Meijborg, V. M. F., van Dam, P. M., van Dessel, P. F. H. M., Belterman, C. N. W., Streekstra, G. J., de Bakker, J. M. T., Coronel, R., & Oostendorp, T. F. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.116.004104 · Cited by 36
Cheniti, G., Puyo, S., Martin, C., Frontera, A., Vlachos, K. G., Takigawa, M., Bourier, F. J., Kitamura, Τ., Lam, A., Dumas-Pomier, C., et al. (2019) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2019.05.004 · Cited by 35
Accuracy of Quadratic Versus Linear Interpolation in Noninvasive Electrocardiographic Imaging (ECGI)
Ghosh, S., & Rudy, Y. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-5537-x · Cited by 31
Self-citationOn epicardial potential reconstruction using regularization schemes with the L1-norm data term
Shou, G., Xia, L., Liu, F., Jiang, M., & Crozier, . (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/004 · Cited by 30
Patient Specific Simulation of Body Surface ECG using the Finite Element Method
Okada, J., SASAKI, T., Washio, T., Yamashita, H., Kariya, T., Imai, Y., Nakagawa, M., Kadooka, Y., Nagai, R., Hisada, T., et al. (2013) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12057 · Cited by 29
“3 In fact, many attempts simulating the ECG based on either a mono-or bi-domain formulation of the cell model for cardiac electrophysiology implemented in image-based models of animal and human hearts have been reported, 4–6 though relatively few studies combine these heart models with an image…”
BackgroundAdvanced Mapping Systems To Guide Atrial Fibrillation Ablation: Electrical Information That Matters.
Nedios, S., Sommer, P., Bollmann, A., & Hindricks, G. (2016) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1337 · Cited by 34
Joy, G., Lopes, L. R., Webber, M. R., Ardissino, A. M., WILSON, J. G., Chan, F., Pierce, I., Hughes, R. K., Moschonas, K., Shiwani, H., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2024.01.006 · Cited by 28
Self-citationPhysiology-based regularization of the electrocardiographic inverse problem
Cluitmans, M. J. M., Clerx, M., Vandersickel, N., Peeters, R., Volders, P. G. A., & Westra, R. L. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1595-5 · Cited by 28
“Electrocardiographic imaging (ECGI) aims at noninvasively reconstructing the electrical activity of the heart, based on body-surface potential measurements and a patient-specific torso–heart geometry [5, 18, 21, 22, 28].”
BackgroundCheng, L. K., Sands, G. B., French, R. L., Withy, S. J., Wong, S. P., Legget, M. E., Smith, W., & Pullan, A. J. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345808 · Cited by 28
Ajmaline‐Induced Abnormalities in Brugada Syndrome: Evaluation With ECG Imaging
Pannone, L., Monaco, C., Sorgente, A., Vergara, P., Călburean, P., Gauthey, A., Bisignani, A., Kazawa, S., Strazdas, A., Mojica, J., et al. (2022) · Journal of the American Heart Association · doi:10.1161/jaha.121.024001 · Cited by 30
Leong, K. M. W., Ng, F. S., Roney, C. H., Cantwell, C. D., Shun-Shin, M. J., Linton, N., Whinnett, Z. I., Lefroy, D. C., Davies, D. W., Harding, S. E., et al. (2017) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13375 · Cited by 31
Comparing phase and electrographic flow mapping for persistent atrial fibrillation
Swerdlow, M., Tamboli, M., Alhusseini, M. I., Moosvi, N., Rogers, A. J., Leef, G. C., Wang, P. J., Rillig, A., Brachmann, J., Sauer, W. H., et al. (2019) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13649 · Cited by 27
Provost, J., Costet, A., Wan, E. Y., Gambhir, A., Whang, W., Garan, H., & Konofagou, E. E. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.08.005 · Cited by 27
“While other technologies for non-invasive electrical mapping [16]”
Minute Mechanical-Excitation Wave-Front Propagation in Human Myocardial Tissue
Kanai, H., & Tanaka, M. (2011) · Japanese Journal of Applied Physics · doi:10.1143/jjap.50.07ha01 · Cited by 26
Hocini, M., Shah, A. J., Neumann, T., Kuniss, M., Erkapic, D., Chaumeil, A., Copley, S., Lim, P. B., Kanagaratnam, P., Denis, A., et al. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12700 · Cited by 26
Prakosa, A., Maxime Sermesant, B., Allain, P., Villain, N., Rinaldi, C. A., Rhode, K., Razavi, R., Delingette, H., & Ayache, N. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2281619 · Cited by 26
Liu, C., Eggen, M. D., Swingen, C., Iaizzo, P. A., & He, B. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2202914 · Cited by 26
“Positive mapping results have been reported in both animal studies [11] and clinical studies [13].”
Whole-Heart Modeling Applications to Cardiac Electrophysiology and Electromechanics
Winslow, R. L. (2017) · Cited by 26
Berthon, B., Behaghel, A., Matéo, P., Dansette, P.-M., Favre, H., Ialy-Radio, N., Tanter, M., Pernot, M., & Provost, J. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2898090 · Cited by 26
“ECGi uses hundreds of ECG electrodes and a CT or MRI scan to map the electrical activation of the epicardium by solving an inverse problem [2].”
BackgroundMethodPDE-Aware Deep Learning for Inverse Problems in Cardiac Electrophysiology
Tenderini, R., Pagani, S., Quarteroni, A. M., & Simone Deparis, A. (2022) · SIAM Journal on Scientific Computing · doi:10.1137/21m1438529 · Cited by 25
Varma, N., Ploux, S., Ritter, P., Wilkoff, B. L., Eschalier, R., & Bordachar, P. (2014) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2014.11.012 · Cited by 25
Introduction to Noninvasive Cardiac Mapping
Bear, L. R., Cuculich, P. S., Bernus, O., Efimov, I. R., & Dubois, R. (2015) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2014.11.015 · Cited by 25
Costet, A., Wan, E. Y., Bunting, E., Grondin, J., Garan, H., & Konofagou, E. E. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/22/8105 · Cited by 25
MRI Whole Heart Segmentation Using Discrete Nonlinear Registration and Fast Non-local Fusion
Heinrich, M. P., & Oster, J. (2018) · Lecture notes in computer science · doi:10.1007/978-3-319-75541-0_25 · Cited by 25
Non-invasive body surface electrocardiographic imaging for diagnosis of atrial cardiomyopathy
Eichenlaub, M., Mueller-Edenborn, B., Lehrmann, H., Minners, J., Nairn, D., Loewe, A., Allgeier, J., Jander, N., Allgeier, M., Ruile, P., et al. (2021) · EP Europace · doi:10.1093/europace/euab140 · Cited by 25
Imaging the heart: computer 3-dimensional anatomic models of the heart
Boyett, M. R., Li, J., Inada, S., Dobrzynski, H., Schneider, J. E., Holden, A. V., & Zhang, H. (2005) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2005.06.102 · Cited by 25
“Recently, Ramanathan et al [1] provided a solution of the binverse problem,Q that is, the calculation of the activation sequence of the heart from the surface electrocardiogram.”
Ghosh, S., Avari, J. N., Rhee, E. K., Woodard, P. K., & Rudy, Y. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2007.12.018 · Cited by 24
Self-citationNoninvasive cardiac arrhythmia ablation with particle beams
Graeff, C., & Bert, C. (2018) · Medical Physics · doi:10.1002/mp.12595 · Cited by 26
“Achieving one key-benefit of radiation therapy based arrhythmia treatment, namely noninvasiveness, seems also feasible since recently noninvasive mapping techniques were reported.(29,30)”
Grandits, T., Gillette, K. K., Neic, A., Bayer, J. D., Vigmond, E. J., Pock, T., & Plank, G. (2020) · Journal of Computational Physics · doi:10.1016/j.jcp.2020.109700 · Cited by 23
Molero, R., González‐Ascaso, A., Climent, A. M., & Guillem, M. S. (2023) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2022.12.007 · Cited by 23
Computational Modeling of Cardiac Disease: Potential for Personalized Medicine
Reumann, M., Gurev, V., & Rice, J. J. (2008) · Personalized Medicine · doi:10.2217/17410541.6.1.45 · Cited by 23
Effect of Cardiac Motion on Solution of the Electrocardiography Inverse Problem
Jiang, M., Xia, L., Shou, G., Wei, Q., Liu, F., & Crozier, . (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005967 · Cited by 23
Electrical estimulation of retinal pigment epithelial cells
Gamboa, O. L., Pu, J., Townend, J., Forrester, J. V., Zhao, M., McCaig, C., & Lois, N. (2010) · Experimental Eye Research · doi:10.1016/j.exer.2010.04.018 · Cited by 22
Chamorro-Servent, J., Dubois, R., & Coudière, Y. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00273 · Cited by 22
“The ECGI inverse problem of computing epicardial potentials, 8E, from the body surface measured potentials, 8T , (MacLeod and Brooks, 1998; Ramanathan et al., 2004; Oostendorp et al., 2011; Wang et al., 2011; Oosterom van, 2012; Haissaguerre et al., 2013; Rudy, 2013; Cochet et al., 2014; Dubois et al., 2015; Shah, 201…”
Method
Metadata
- Authors
- Ramanathan, C., Ghanem, R. N., Jia, P., Ryu, K., & Rudy, Y.
- Affiliations
- Case Western Reserve University (US)
- Corresponding author
- Rudy, Yoram
- ORCID
- Venue
- Nature Medicine
- Published
- 2004-03-14
- Volume
- 10
- Issue
- 4
- Pages
- 422-428
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- PMC
- PMC1950745
- OpenAlex
- W2064569583
- Cited by
- 646
- References
- 29
- Citations by year
- 2026: 6 · 2025: 18 · 2024: 35 · 2023: 19 · 2022: 24 · 2021: 42 · 2020: 30 · 2019: 39 · 2018: 36 · 2017: 44 · 2016: 28 · 2015: 32 · 2014: 38 · 2013: 35 · 2012: 33
- FWCI
- 17.51
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Medicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Heart, Lung, and Blood Institute (R01HL049054, R37HL033343)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- electrocardiographic imaging, cardiac electrophysiology, cardiac arrhythmias, noninvasive cardiac imaging, surface electrocardiogram, isochrone mapping, right bundle branch block, ventricular repolarization, atrial flutter, ventricular pacing, atrial activation, ventricular activation
- MeSH terms
- Arrhythmias, Cardiac, Electrocardiography, Heart, Heart Atria, Heart Ventricles, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.