Noninvasive electrocardiographic imaging for cardiac electrophysiology and arrhythmia
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Over 7 million people worldwide die annually from erratic heart rhythms (cardiac arrhythmias), and many more are disabled. Yet there is no imaging modality to identify patients at risk, provide accurate diagnosis and guide therapy. Standard diagnostic techniques such as the electrocardiogram (ECG) provide only low-resolution projections of cardiac electrical activity on the body surface. Here we demonstrate the successful application in humans of a new imaging modality called electrocardiographic imaging (ECGI), which noninvasively images cardiac electrical activity in the heart. In ECGI, a multielectrode vest records 224 body-surface electrocardiograms; electrical potentials, electrograms and isochrones are then reconstructed on the heart's surface using geometrical information from computed tomography (CT) and a mathematical algorithm. We provide examples of ECGI application during atrial and ventricular activation and ventricular repolarization in (i) normal heart (ii) heart with a conduction disorder (right bundle branch block) (iii) focal activation initiated by right or left ventricular pacing, and (iv) atrial flutter.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“BSPM has nowadays got a real clinical breakthrough as a method for non-invasive 3D EAI, with the competitive concept of “ECG imaging” (ECGi) (239–241), a technology that has rapidly evolved in clinically available devices (242), increasingly used for non-invasive pre-interventional assessment of patients undergoing catheter ablation procedures (243, 244).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [239]
Citations
Cites
Solutions of Ill-Posed Problems.
Bell, J. B., Tikhonov, A. N., & Arsenin, V. Y. (1978) · Mathematics of Computation · doi:10.2307/2006360 · Cited by 8,101
Total Excitation of the Isolated Human Heart
DURRER, D., VAN DAM, R. T., FREUD, G. E., JANSE, M. J., MEIJLER, F. L., & ARZBAECHER, R. C. (1970) · Circulation · doi:10.1161/01.cir.41.6.899 · Cited by 1,777
Janse, M. J., & Wit, A. L. (1989) · Physiological Reviews · doi:10.1152/physrev.1989.69.4.1049 · Cited by 1,018
Haws, C. W., & Lux, R. L. (1990) · Circulation · doi:10.1161/01.cir.81.1.281 · Cited by 397
Ionic Current Basis of Electrocardiographic Waveforms: A Model Study
Gima, K., & Rudy, Y. (2002) · Circulation Research · doi:10.1161/01.res.0000016960.61087.86 · Cited by 396 · cited 1×
“Normal repolarization potential patterns have no direct relationship to depolarization patterns because the T-wave is determined mostly by local intrinsic repolarization propertie”
BackgroundSelf-citationSOSA, E., SCANAVACCA, M., D'AVILA, A., PICCIONI, J., SANCHEZ, O., VELARDE, J. L., SILVA, M., & REOLÃO, B. (1998) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1998.tb00907.x · Cited by 330 · cited 1×
“More than a third of clinical ventricular tachycardia cases involve the subepicardium, an observation that led to the development of transthoracic epicardial ablation to treat ventricular tachycardi”
BackgroundOster, H. S., Taccardi, B., Lux, R. L., Ershler, P. R., & Rudy, Y. (1997) · Circulation · doi:10.1161/01.cir.96.3.1012 · Cited by 256
Self-citationOster, H. S., TACCARDI, B., Lux, R. L., Ershler, P. R., & Rudy, Y. (1998) · Circulation · doi:10.1161/01.cir.97.15.1496 · Cited by 140
Self-citationEpicardial activation of the intact human heart without conduction defect.
Wyndham, C. R. C., Meeran, M. K., Smith, T., Saxena, A., Engelman, R. M., Levitsky, S., & Rosen, K. M. (1979) · Circulation · doi:10.1161/01.cir.59.1.161 · Cited by 127
A Noninvasive Imaging Modality for Cardiac Arrhythmias
Burnes, J. E., TACCARDI, B., & Rudy, Y. (2000) · Circulation · doi:10.1161/01.cir.102.17.2152 · Cited by 125
Self-citation
Research works printed but not linked: 1
- Biermann, M. et al. The interpretation of cardiac electrograms. in Cardiac Mapping (eds. Shenasa, M., Borggrefe, M. & Breithardt, G.) 15–39 (Futura Publishing, Mount Kisco, New York, 2003).
Cited by
Items 201–300 of 659
Classification of Myocardial Ischemia in Delayed Contrast Enhancement Using Machine Learning
Merjulah, R., & Chandra, J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815553-0.00011-2 · Cited by 22
Electromechanical Wave Imaging of Biologically and Electrically Paced Canine Hearts in Vivo
Costet, A., Provost, J., Gambhir, A., Bobkov, Y., Danilo, P., Boink, G. J. J., Rosen, M. R., & Konofagou, E. E. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.08.019 · Cited by 21
“A major recent advance is electrocardiographic imaging (Ramanathan et al. 2004; Zhang et al. 2005), which reconstructs action potentials based on body surface potential measurements, but is limited to the epicardium and is dependent on patient-specific modeling derived from X-ray computed…”
Rahimi, A., Sapp, J. L., Xu, J., Bajorski, P., Horáček, B. M., & Wang, L. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2464315 · Cited by 21
“The source models are then commonly defined in forms of electrical potential on the epicardium and/or endocardium [6], [12]–[14], or activation time on the ventricular surface [15]–[17].”
BackgroundJanssen, A. M., Potyagaylo, D., Dössel, O., & Oostendorp, T. F. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-017-1715-x · Cited by 21
“Two popular surface source models are the epicardial potential model [2, 38, 42] and the equivalent dipole layer (EDL) model [9, 12, 13, 36].”
MethodElectromechanical Wave Imaging With Machine Learning for Automated Isochrone Generation
Melki, L., Tourni, M., & Konofagou, E. E. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3074808 · Cited by 24
“The imaging techniques currently available to clinicians for cardiac activation sequence mapping are invasive, ionizing, time-consuming and costly [10], [11], [12].”
MethodVectorcardiogram synthesized from the 12-lead electrocardiogram to image ischemia
Strauss, D. G., Olson, C. W., Wu, K. C., Heiberg, E., Persson, E., Selvester, R. H. S., Pahlm, O., & Arheden, H. (2009) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2008.12.018 · Cited by 21
Kvåle, K. F., Bersvendsen, J., Remme, E. W., Salles, S., Aalen, J. M., Brekke, P. H., Edvardsen, T., & Samset, E. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2909358 · Cited by 21
“scans for geometrical information [10].”
Leong, K. M. W., Ng, F. S., Yao, C., Roney, C. H., Taraborrelli, P., Linton, N. W. F., Whinnett, Z. I., Lefroy, D. C., Davies, D. W., Lim, P. B., et al. (2017) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.117.005107 · Cited by 20
Rigal, L., Bénali, K., Barré, V., Hamel-Bougault, M., Bellec, J., de Crevoisier, R., Martins, R. P., & Simon, A. (2023) · Medical Physics · doi:10.1002/mp.16613 · Cited by 20
Roten, L., Pedersen, M. E. F., Pascale, P., Shah, A. J., Eliautou, S., SCHERR, D., Sacher, F., & Haïssaguerre, M. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02250.x · Cited by 20
“The electrocardiographic mapping system consists of a multielectrode sensor array that records 250 electrocardiograms from the torso and uses the anatomy of the epicardial surface obtained from a computed tomography scan to reconstruct the signals on atrial or ventricular epicardial electroanatomic maps.(1) In the atr…”
MethodVarma, N. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.03.052 · Cited by 20
Pannone, L., Monaco, C., Sorgente, A., Vergara, P., Gauthey, A., Călburean, P., Bisignani, A., Paparella, G., Ramak, R., Overeinder, I., et al. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.01.034 · Cited by 22
Noninvasive Estimation of Global Activation Sequence Using the Extended Kalman Filter
Liu, C., & He, B. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2066564 · Cited by 20
“Apopulartrendofthecardiacinverseapproachisestimatingthe epicardialpotentialsfromtheBSPMs[3]‐[6],andtheepicardial activation sequence can be subsequently derived from the estimated potentials [ 7 ].”
BackgroundComputationally Efficient Noninvasive Cardiac Activation Time Imaging
Pfeifer, B. E., Seger, M., Hintermüller, C., Hanser, F., Modre, R., TILG, B., Trieb, T., Kremser, C., Roithinger, F. X., Hintringer, F., et al. (2005) · Methods of Information in Medicine · doi:10.1055/s-0038-1634024 · Cited by 21
“Individual anatomy can be obtained by magnetic resonance imaging (MRI) [5, 6] or computed tomography (CT) [7].”
BackgroundMethodStatistical Variations of Heart Orientation in Healthy Adults
Odille, F., Liu, S., van Dam, P. M., & Felblinger, J. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.225-058 · Cited by 20
Rudy, Y. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.627964 · Cited by 20
Self-citationFukuoka, Y., Oostendorp, T. F., Sherman, D. A., & Armoundas, A. A. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880882 · Cited by 20
Pison, L., Proclemer, A., Bongiorni, M. G., Marinskis, G., Hernández‐Madrid, A., & Blomström‐Lundqvist, C. (2013) · EP Europace · doi:10.1093/europace/eut259 · Cited by 19
“These data are then reconstructed on the heart surface using information from cardiac CT and a mathematical algorithm.(18) This promising technology has already been applied successfully in supraventricular and ventricular arrhythmias, but so far there is no prospective randomized data available.”
MethodBokeriya, L. A., Revishvili, A. S., Kalinin, A. V., Kalinin, V. V., Lyadzhina, O. A., & Фетисова, Е. А. (2008) · Biomedical Engineering · doi:10.1007/s10527-009-9065-0 · Cited by 19
Surgery for Lone Atrial Fibrillation: Present State-of-the-Art
Shen, J., Bailey, M. S., & Damiano, R. J. (2009) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1097/imi.0b013e3181bb370f · Cited by 23
Noninvasive Imaging of Cardiac Excitation: Current Status and Future Perspective
van der Graaf, A. W. M., Bhagirath, P., Ramanna, H., van Driel, V. J. H. M., de Hooge, J., de Groot, N. M. S., & Götte, M. (2014) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12140 · Cited by 19
Body Surface ECG Signal Shape Dispersion
Khaddoumi, B., Rix, H., Meste, O., Fereniec, M., & Maniewski, R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.881785 · Cited by 19
“A lot of studies have showed its high diagnostic power [5]–[7], as well as its utility in inverse procedures: for example, pericardial potentials [8], epicardial activation times or potentials [9], [ 10 ], are reconstructed.”
BackgroundShi, R., Norman, M. W., Chen, Z., & Wong, T. (2018) · Future Cardiology · doi:10.2217/fca-2017-0109 · Cited by 22
Reconstruction of the 12‐lead ECG using a novel MR‐compatible ECG sensor network
Reis, J. E. D., Soullié, P., Oster, J., Soler, E. P., Petitmangin, G., Felblinger, J., & Odille, F. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27854 · Cited by 19
Hohmann, S., Rettmann, M. E., Konishi, H., Borenstein, A., Wang, S., Suzuki, A., Michalak, G. J., Monahan, K. H., Parker, K. D., Newman, L. K., et al. (2019) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.119.007570 · Cited by 19
Roudijk, R. W., Boonstra, M., Brummel, R., Kassenberg, W., Blom, L. J., Oostendorp, T. F., Riele, A. S. J. M. T., van der Heijden, J. F., Asselbergs, F. W., van Dam, P. M., et al. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.730736 · Cited by 19
Jiang, M., Zhu, L., Wang, Y., Xia, L., Shou, G., Liu, F., & Crozier, . (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/6/013 · Cited by 19
Nakai, K., Tsuboi, J., Okabayashi, H., Fukushima, A., Itoh, M., Kawata, H., Miyake, F., & Kasanuki, H. (2007) · International Heart Journal · doi:10.1536/ihj.48.701 · Cited by 19
Analyzing High-Density ECG Signals Using ICA
Zhu, Y., Shayan, A., Zhang, W., Chen, T. L., Jung, T., Duann, J., Makeig, S., & Cheng, C. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2001262 · Cited by 19
“Recordings with more channels have been used by other researchers such as [8]–[10], but these researchers have not tested the application of ICA to their data.”
MethodIs Mapping of Complex Fractionated Electrograms Obsolete?
Sohal, M., Choudhury, R., Taghji, P., Louw, R., Wolf, M., Fedida, J., Vandekerckhove, Y. R., Tavernier, R., Duytschaever, M. F., Knecht, S., et al. (2015) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2015.04.02.109 · Cited by 19
A Luenberger observer for reaction–diffusion models with front position data
Collin, A., Chapelle, D., & Moireau, P. (2015) · Journal of Computational Physics · doi:10.1016/j.jcp.2015.07.044 · Cited by 19
“For instance, in electrophysiology, Electrocardiographic Imaging (ECGI) aims at reconstructing cardiac potential isochrones [70].”
BackgroundMethodDevelopment of a portable wireless system for bipolar concentric ECG recording
Prats-Boluda, G., Ye-Lin, Y., Bueno-Barrachina, J.-M., Senent, E. G., de Sanabria, R. R., & Garcia‐Casado, J. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/26/7/075102 · Cited by 18
Meinel, A., Castaño-Candamil, S., Blankertz, B., Lotte, F., & Tangermann, M. (2018) · Neuroinformatics · doi:10.1007/s12021-018-9396-7 · Cited by 20
Christoph, J., & Lebert, J. (2020) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/5.0023751 · Cited by 18
Nakai, K., Miyake, F., Kasanuki, H., Shoda, M., Futagawa, K., Takahashi, A., Matsuyama, Y., Nirei, T., Tsuboi, J., Okabayashi, H., et al. (2008) · International Heart Journal · doi:10.1536/ihj.49.153 · Cited by 18
Study protocol: MyoFit46—the cardiac sub-study of the MRC National Survey of Health and Development
Webber, M. R., Falconer, D., Alfarih, M., Joy, G., Chan, F., Davie, C., Howes, L. H., Wong, A., Rapala, A., Bhuva, A., et al. (2022) · BMC Cardiovascular Disorders · doi:10.1186/s12872-022-02582-0 · Cited by 17
Self-citationSaffitz, J. E., & Corradi, D. (2015) · Cardiovascular Pathology · doi:10.1016/j.carpath.2015.11.005 · Cited by 22
Synchronization-based reconstruction of electromechanical wave dynamics in elastic excitable media
Lebert, J., & Christoph, J. (2019) · Chaos An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.5101041 · Cited by 17
Elliott, M. K., Strocchi, M., Sieniewicz, B., Mehta, V. S., Wijesuriya, N., de Vere, F., Howell, S., Thorpe, A., Martic, D., Bishop, M. J., et al. (2023) · Heart Rhythm · doi:10.1016/j.hrthm.2023.07.065 · Cited by 17
Rudy, Y. (2006) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2006.03.012 · Cited by 17
“The following observations were made: (1) activation patterns during NR were very heterogeneous among patients; (2) RV pacing alone was not effective for improving electrical synchronization in most patients; (3) LV pacing alone often improved electrical synchrony as much as BiV pacing, and this was achieved through f…”
Self-citationTwo hybrid regularization frameworks for solving the electrocardiography inverse problem
Jiang, M., Xia, L., Shou, G., Liu, F., & Crozier, . (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/18/020 · Cited by 17
Clinical use of body surface potential mapping in cardiac arrhythmias.
Ambroggi, L. D., & Corlan, A. D. (2007) · PubMed · Cited by 17
ECG Signal Acquisition Systems
Salinet, J. L., & Silva, O. L. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-814035-2.00008-6 · Cited by 17
Electrocardiographic imaging in the atria
Hernández‐Romero, I., Molero, R., Santos, C. F., Herrero-Martín, C., Climent, A. M., & Guillem, M. S. (2022) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02709-7 · Cited by 24
Rickard, J., JACKSON, K. P., Gold, M. R., Biffi, M., Ziacchi, M., Silverstein, J., Ramza, B. M., Metzl, M. D., Grubman, E. M., Abben, R. P., et al. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.11.015 · Cited by 17
Webber, M. R., Joy, G., Bennett, J. B., Chan, F., Falconer, D., Shiwani, H., Davies, R. H., Krausz, G., Tanackovic, S., Guger, C., et al. (2023) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-023-00980-7 · Cited by 17
“The pre and post processing steps of the ECG signals collected have been described in detail elsewhere [8, 9, 16, 39].”
MethodResultInfluentialSelf-citationChamorro-Servent, J., Dubois, R., Potse, M., & Coudière, Y. (2017) · Lecture notes in computer science · doi:10.1007/978-3-319-59448-4_28 · Cited by 16
“During the past decades, much progress has been made in solving the inverse problem of electrocardiography [1-7].”
BackgroundAtrial tachycardias: Cause or effect with ablation of persistent atrial fibrillation?
Yamashita, S., Hooks, D. A., Shah, A. J., Relan, J., Cheniti, G., Kitamura, Τ., Berte, B., Mahida, S., Sellal, J., Al-Jefairi, N., et al. (2017) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13377 · Cited by 16
Otani, N. F., Luther, S., Singh, R., & Gilmour, R. F. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0071-x · Cited by 16
Updates in Cardiac Resynchronization Therapy for Chronic Heart Failure: Review of Multisite Pacing
Antoniadis, A. P., Sieniewicz, B., Gould, J., Porter, B., Webb, J., Claridge, S., Behar, J. M., & Rinaldi, C. A. (2017) · Current Heart Failure Reports · doi:10.1007/s11897-017-0350-z · Cited by 16
The Forward Problem of Electrocardiography Revisited
Rudy, Y. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003056 · Cited by 17
Self-citationNoninvasive Mapping of Repolarization With Electrocardiographic Imaging
Rudy, Y. (2021) · Journal of the American Heart Association · doi:10.1161/jaha.121.021396 · Cited by 16
Self-citationTotal Variation Regularization in Electrocardiographic Mapping
Shou, G., Xia, L., & Jiang, M. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-15615-1_7 · Cited by 15
“The most common regularization methods are the Tikhonov regularization[ 2-3 ], which imposes the constraints on the magnitude or derivatives of the EPs.”
MethodAlday, E. A. P., Haq, K. T., German, D. M., Hamilton, C., Johnson, K., Phan, F. T., Rogovoy, N. M., Yang, K. Y., Wirth, A., Thomas, J., et al. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00344 · Cited by 15
“Recently, the non-invasive electrocardiographic imaging (ECGi), a state-of-the-art technology, became available as a tool to study mechanisms of cardiac arrhythmias (Ramanathan et al., 2004).”
MethodVarma, N. (2013) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2013.09.001 · Cited by 15
“Methodology has been detailed previously [17,18].”
Waddingham, P. H., Mangual, J. O., Orini, M., Badie, N., Muthumala, A. G., Sporton, S. C., McSpadden, L. C., Lambiase, P. D., & CHOW, A. W. C. (2022) · EP Europace · doi:10.1093/europace/euac224 · Cited by 15
“A 252-electrode vest (CardioInsight, Medtronic, MN) was used to record body surface potentials (1000 Hz sampling rate), as previously described.(11) The vest remained in situ for the duration of the mapping procedure following a low dose non-contrast axial computed tomography (CT) scan with 3-mm slice thickness.”
MethodTime-Delay Mapping of High-Resolution Gastric Slow-Wave Activity
Paskaranandavadivel, N., O’Grady, G., & Cheng, L. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2548940 · Cited by 15
“clinical success, guiding diagnosis, and interventional therapies in cardiac and neural fields [1]–[4].”
Electrocardiographic imaging of normal human atrial repolarization
Wang, Y., & Rudy, Y. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.07.024 · Cited by 15
Self-citationGattinger, J., Schönberger, M., Wintermantel, E., Rau, A., & Wolff, K. D. (2014) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2014-5012 · Cited by 16
Wavelet-promoted sparsity for non-invasive reconstruction of electrical activity of the heart
Cluitmans, M. J. M., Karel, J. M. H., Bonizzi, P., Volders, P. G. A., Westra, R. L., & Peeters, R. (2018) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-018-1831-2 · Cited by 15
“Electrocardiographic imaging (ECGI) non-1invasively reconstructs potentials, electrograms, and activation/recovery isochrones directly at the heart surface from body-surface potential measurements and a patient-specific torso-heart geometry [5, 7, 33, 34] (see Fig.”
Jiang, X., Toloubidokhti, M., Bergquist, J., Zenger, B., Good, W. W., MacLeod, R., & Wang, L. (2022) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3218170 · Cited by 14
“Overall, in this line of classic physics-based approaches, it is established that the accuracy of ECGI would rely on a forward operator that is specific to a subject’s heart-torso geometry [20], [29].”
BackgroundResultCiaccio, E. J., Hiatt, M., Hegyi, T., & Drzewiecki, G. M. (2007) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-6-13 · Cited by 14
“strapped to the chest [11] or held in place by a pneumatic mechanism [12].”
Experimental Measures of Ventricular Activation and Synchrony
Sutherland, D. R., Ni, Q., MacLeod, R., Lux, R. L., & Punske, B. B. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01227.x · Cited by 14
Cuculich, P. S., Wang, Y., Lindsay, B. D., Vijayakumar, R., & Rudy, Y. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.11.009 · Cited by 14
“The ECGI procedure has been described previously (2) (3).”
MethodSelf-citationA NOVEL METHOD TO ISCHEMIC HEART DISEASE DETECTION BASED ON NON-INVASIVE ECG IMAGING
Moridani, M. K., & Pouladian, M. (2018) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519419500027 · Cited by 15
van der Waal, J. G., Meijborg, V. M. F., Schuler, S., Coronel, R., & Oostendorp, T. F. (2020) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-020-02203-y · Cited by 14
Modelling and imaging cardiac repolarization abnormalities
Rudy, Y. (2005) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2005.01586.x · Cited by 14
Self-citationRahimi, A., & Wang, L. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2395387 · Cited by 13
“Developments in the past three decades have led to applications of EP imaging in important clinical problems, such as ventricular arrhythmia [11], [12], dyssynchronous heart failure [13], atrial fibrillation [14], and myocardial ischemia [15].”
Elliott, M. K., Strocchi, M., Mehta, V. S., Wijesuriya, N., Mannakkara, N. N., Jackson, T., Pereira, H., Behar, J. M., Bishop, M. J., Niederer, S., et al. (2022) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2022.04.001 · Cited by 13
“Epicardial potentials were reconstructed from the body surface potentials and CT-derived heart-torso geometry as previously described [18], and exported for analysis.”
MethodModern Electrophysiology Mapping Techniques
Sy, R. W., Thiagalingam, A., & Stiles, M. K. (2012) · Heart Lung and Circulation · doi:10.1016/j.hlc.2012.04.007 · Cited by 16
Berenfeld, O. (2010) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2010.06.005 · Cited by 13
Zhang, J., Desouza, K. A., Cuculich, P. S., Cooper, D. H., Chen, J., & Rudy, Y. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.01.001 · Cited by 13
Self-citationHolzem, K. M., Madden, E. J., & Efimov, I. R. (2014) · EP Europace · doi:10.1093/europace/euu264 · Cited by 13
“85 Currently, though, this technology is only able to resolve electrograms on the epicardial surface, asthe inverseproblemusing bodysurfaceelectro-grams to determine cardiac electrogram morphologies is ill-posed.”
BackgroundThe relation between local repolarization and T-wave morphology in heart failure patients
Maffessanti, F., Wanten, J., Potse, M., Regoli, F. D., Caputo, M. L., Conte, G., Sürder, D., Illner, A., Krause, R., Moccetti, T., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.02.056 · Cited by 13
“Useful informationmay be derived from epicardialmapping, whichmay be easiest obtained using the ECGimaging technique [33].”
MethodNoninvasive electrocardiographic imaging with low-rank and non-local total variation regularization
Mu, L., & Liu, H. (2020) · Pattern Recognition Letters · doi:10.1016/j.patrec.2020.07.007 · Cited by 13
Negative-ResNet: noisy ambulatory electrocardiogram signal classification scheme
Chen, Z., Lin, Z., Wang, P., & Ding, M. (2021) · Neural Computing and Applications · doi:10.1007/s00521-020-05635-7 · Cited by 23
Vahlhaus, C. (2004) · European Heart Journal · doi:10.1016/j.ehj.2003.10.019 · Cited by 13
Concepts of Cardiac Dyssynchrony and Dynamic Approach
Catrina, B. I., Batâr, F., Maniţiu, I., Prodan, L., Tanasescu, C. A. H., & Filip, T. (2024) · Diagnostics · doi:10.3390/diagnostics14090937 · Cited by 12
“By utilizing body surface potential measurements gated from 200 electrodes positioned around the chest and coupled with the patient-specific heart–torso geometry, a more advanced technology is capable of reconstructing the electro-anatomical activation of the epicardium [22].”
MethodStoks, J., Patel, K. H. K., van Rees, B., Nguyên, U. C., Mihl, C., Deissler, P., ter Bekke, R. M. A., Peeters, R., Vijgen, J. M., Dendale, P., et al. (2024) · EP Europace · doi:10.1093/europace/euae172 · Cited by 12
Elliott, M. K., Mehta, V. S., Sidhu, B. S., Niederer, S., & Rinaldi, C. A. (2020) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2020.04.012 · Cited by 12
“The patient was fitted with a 252-electrode CardioInsight Sensor Array Vest (Medtronic, Minneapolis, MN) before the procedure and underwent a low-dose computed tomography scan to obtain electrode and cardiac positions, as previously described.(5) Conventional CRT was delivered through the implanted CRT-D device.”
MethodArnold, A. D., Shun-Shin, M. J., Ali, N., Keene, D., Howard, J. P., Chow, J., Qureshi, N. A., Koa‐Wing, M., Tanner, M. A., Lefroy, D. C., et al. (2021) · Heart Rhythm O2 · doi:10.1016/j.hroo.2021.08.001 · Cited by 12
Catheter ablation of ventricular tachycardia: Two decades of progress
Wilber, D. J. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.02.001 · Cited by 12
Jiang, M., Liu, F., Wang, Y., Shou, G., Huang, W., & Zhang, H. (2012) · Computational and Mathematical Methods in Medicine · doi:10.1155/2012/436281 · Cited by 12
“The technique of noninvasive imaging of the heart’s electrical activity from the body surface potentials (BSPs) constitutes one form of the inverse problem of ECG [1, 2].”
MethodA 64-Lead Body Surface Potential Mapping System
Salinet, J. L., Marques, V. G., Mazzetto, M., de Camargo, E. D. L. B., Pastore, C. A., & Cestari, I. A. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.053-337 · Cited by 14
“A developed device called Body Surface Potential Mapping (BSPM) has been utilized in both research and clinical practices [7] allowing real-time acquisition of BSPs over a range of 32 to 300 electrodes providing better diagnostics of several heart disturbances [1, 4, 5].”
MethodMarques, V. G., Rodrigo, M., Guillem, M. S., & Salinet, J. L. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab97c1 · Cited by 12
“epicardial (or endocardial) electrical activity [8].”
Ruipérez-Campillo, S., Castrejón, S. C., Martínez, M., Cervigón, R., Meste, O., Merino, J. L., Millet, J., & Castells, F. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.105932 · Cited by 12
Wetterling, F., Liehr, M., Schimpf, P. H., Liu, H., & Haueisen, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/18/003 · Cited by 12
“Recently, for example, electrocardiographic imaging (ECGI) methods have been proposed for patients with and without risk of life-threatening cardiac arrhythmia (Ramanathan et al 2004).”
BackgroundCardiac repolarization: Insights from mathematical modeling and electrocardiographic imaging (ECGI)
Rudy, Y. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.07.021 · Cited by 14
Self-citationThe Consortium on Electrocardiographic Imaging
Coll‐Font, J., Brooks, D. H., van Dam, P. M., Dhamala, J., Dössel, O., Guillem, M. S., MacLeod, R., Potyagaylo, D., Schulze, W. H. W., Tate, J. D., et al. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.094-431 · Cited by 12
“However, progress has been limited by the lack of both standards and unbiased comparisons of approaches and techniques across the community, as well as the consequent difficulty of effective collaboration across research groups..”
BackgroundLocalization of ventricular activation origin using patient‐specific geometry: Preliminary results
Zhou, S., Sapp, J. L., AbdelWahab, A. M., Šťovíček, P., & Horáček, B. M. (2018) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13622 · Cited by 12
Li, L., Smith, H. J., Lyu, Y., Camps, J., Qian, S., Rodríguez, B., Banerjee, A., & Grau, V. (2025) · Medical Image Analysis · doi:10.1016/j.media.2025.103472 · Cited by 11
Calkins, H. G., Hindricks, G., Cappato, R., Kim, Y., Saad, E., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, A. J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.07.001 · Cited by 11
Hayashi, A., Mori, S., Arakawa, M., & Kanai, H. (2019) · Japanese Journal of Applied Physics · doi:10.7567/1347-4065/ab0d0b · Cited by 11
Electrocardiographic Imaging: A Comparison of Iterative Solvers
Borràs, M., & Chamorro-Servent, J. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.620250 · Cited by 11
Kawaji, T., Aizawa, T., Hojo, S., Yaku, H., Nakatsuma, K., Kaneda, K., Kato, M., Yokomatsu, T., & Miki, S. (2022) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14502 · Cited by 11
Analysis of complex excitation patterns using Feynman-like diagrams
Arno, L., Kabus, D., & Dierckx, H. (2024) · Scientific Reports · doi:10.1038/s41598-024-73544-z · Cited by 11
“Therefore, the concepts of heads and tails may also prove useful when improving efficient inverse methods to recover spatiotemporal activation sequences from patient measurements Ramanathan et al. [2004].”
The use of non-invasive mapping in persistent AF to predict acute procedural outcome
Gao, X., Lam, A., Bilchick, K. C., Darby, A., Mehta, N. K., Mason, P. K., Malhotra, R., & Mangrum, J. M. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2019.08.012 · Cited by 11
Kommata, V., Elshafie, M., Sciaraffia, E., Perez, M. D., Augustine, R., & Blomström‐Lundqvist, C. (2021) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14295 · Cited by 11
Pervolaraki, E., Hodgson, S., Holden, A. V., & Benson, A. P. (2014) · EP Europace · doi:10.1093/europace/eut377 · Cited by 14
Kahn, A. M., Krummen, D. E., Feld, G. K., & Narayan, S. M. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2006.12.042 · Cited by 11
Metadata
- Authors
- Ramanathan, C., Ghanem, R. N., Jia, P., Ryu, K., & Rudy, Y.
- Affiliations
- Case Western Reserve University (US)
- Corresponding author
- Rudy, Yoram
- ORCID
- Venue
- Nature Medicine
- Published
- 2004-03-14
- Volume
- 10
- Issue
- 4
- Pages
- 422-428
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- PMC
- PMC1950745
- OpenAlex
- W2064569583
- Cited by
- 646
- References
- 29
- Citations by year
- 2026: 6 · 2025: 18 · 2024: 35 · 2023: 19 · 2022: 24 · 2021: 42 · 2020: 30 · 2019: 39 · 2018: 36 · 2017: 44 · 2016: 28 · 2015: 32 · 2014: 38 · 2013: 35 · 2012: 33
- FWCI
- 17.51
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Medicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Heart, Lung, and Blood Institute (R01HL049054, R37HL033343)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- electrocardiographic imaging, cardiac electrophysiology, cardiac arrhythmias, noninvasive cardiac imaging, surface electrocardiogram, isochrone mapping, right bundle branch block, ventricular repolarization, atrial flutter, ventricular pacing, atrial activation, ventricular activation
- MeSH terms
- Arrhythmias, Cardiac, Electrocardiography, Heart, Heart Atria, Heart Ventricles, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.