CoChat

Multi-pulse drug delivery from a resorbable polymeric microchip device

The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.

Abstract

Controlled-release drug delivery systems have many applications, including treatments for hormone deficiencies and chronic pain. A biodegradable device that could provide multi-dose drug delivery would be advantageous for long-term treatment of conditions requiring pulsatile drug release. In this work, biodegradable polymeric microchips were fabricated that released four pulses of radiolabelled dextran, human growth hormone or heparin in vitro. Heparin that was released over 142 days retained on average 96 +/- 12% of its bioactivity. The microchips were 1.2 cm in diameter, 480-560 microm thick and had 36 reservoirs that could each be filled with a different chemical. The devices were fabricated from poly(L-lactic acid) and had poly(D,L-lactic-co-glycolic acid) membranes of different molecular masses covering the reservoirs. A drug delivery system can be designed with the potential to release pulses of different drugs at intervals after implantation in a patient by using different molecular masses or materials for the membrane.

Overview

Integrity signals

Registry

Crossref · 10.1038/nmat998

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 52 references

Research works printed but not linked: 2

  1. Santini, J.T. Jr, Richards, A.C., Scheidt, R., Cima, M.J. & Langer, R. Microchips as controlled drug-delivery devices. Angew. Chem. Int. Edn 39, 2396–2407 (2000). · DOI · Paper page
  2. Kost, J. & Langer, R. in Pulsed and Self-Regulated Drug Delivery (ed. Kost, J.) 3–16 (CRC Press, Boca Raton, Florida, 1990).

Cited by

Items 101–200 of 443

Metadata

Authors
Grayson, A. C. R., Choi, I. S., Tyler, B. M., Wang, P. P., Brem, H., Cima, M. J., & Langer, R.
Affiliations
  • Cornell University (US)
  • Korea Advanced Institute of Science and Technology (KR)
  • Johns Hopkins University (US)
  • Massachusetts Institute of Technology (US)
Venue
Nature Materials
Published
2003-10-19
Volume
2
Issue
11
Pages
767-772
ISSN
  • 1476-1122 (ISSN-L)
  • 1476-4660
OpenAlex
W1969757222
Cited by
444
References
52
Citations by year
2026: 3 · 2025: 10 · 2024: 8 · 2023: 11 · 2022: 14 · 2021: 16 · 2020: 18 · 2019: 14 · 2018: 17 · 2017: 14 · 2016: 20 · 2015: 22 · 2014: 20 · 2013: 36 · 2012: 25
FWCI
16.67
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Nature Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Allergy and Infectious Diseases (R24-AI47739-02, R24AI047739)
Topics
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advanced Drug Delivery Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
Keywords
controlled drug delivery, poly(L-lactic acid), PLGA membranes, heparin, human growth hormone, dextran
MeSH terms
Dextrans, Drug Administration Schedule, Drug Carriers, Drug Compounding, Drug Implants, Equipment Design, Feasibility Studies, Heparin, Miniaturization, Polyesters, Polymers, Lactic Acid, Human Growth Hormone, Equipment Failure Analysis, Coated Materials, Biocompatible, Absorbable Implants

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.