The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Label-free biomarker detection from whole blood
Open accessAbstract
Label-free nanosensors can detect disease markers to provide point-of-care diagnosis that is low-cost, rapid, specific and sensitive. However, detecting these biomarkers in physiological fluid samples is difficult because of ionic screening. Here, we overcome this limitation by using distinct components within the sensor to perform purification and detection.1 A microfluidic purification chip captures multiple biomarkers simultaneously from blood samples and releases them, after washing, into purified buffer for sensing by a silicon nanoribbon detector. This two-stage approach isolates the detector from the complex environment of whole blood, and reduces its minimum required sensitivity by effectively pre-concentrating the biomarkers. We show specific and quantitative detection of two model cancer antigens from a 10 uL sample of whole blood in less than 20 minutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Siegel, R., Ward, E., Hao, Y., Xu, J., Murray, T., & Thun, M. J. (2008) · CA: A Cancer Journal for Clinicians · doi:10.3322/ca.2007.0010 · Cited by 10,188
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Present and future of surface plasmon resonance biosensors
Homola, J. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2101-0 · Cited by 2,321
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Self-citationWeighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
Etzioni, R., Urban, N., Ramsey, S., McIntosh, M., Schwartz, S., Reid, B., Radich, J., Anderson, G., & Hartwell, L. (2003) · Nature Reviews Cancer · doi:10.1038/nrc1041 · Cited by 1,155
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Self-citation(1997) · General Pharmacology: The Vascular System · doi:10.1016/s0306-3623(97)89864-3 · Cited by 750
Fan, R., Vermesh, O., Srivastava, A., Yen, B. K. H., Qin, L., Ahmad, H., Kwong, G. A., Liu, C.-C., Gould, J., Hood, L., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1507 · Cited by 539
Biophysical chemistry. Part III, The behavior of biologicalmacromolecules
Cantor, C. R., & SCHIMMEL, P. R. (1980) · Cited by 500
Bunimovich, Y. L., Shin, Y. S., Yeo, W.-S., Amori, M., Kwong, G., & Heath, J. R. (2006) · Journal of the American Chemical Society · doi:10.1021/ja065923u · Cited by 480
Nanotechnology in clinical laboratory diagnostics
Jain, K. K. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.03.014 · Cited by 453
Biophysical Chemistry Part III: The Behavior of Biological Macromolecules
Cox, R. A. (1981) · FEBS Letters · doi:10.1016/0014-5793(81)80070-1 · Cited by 431
Quantitative proteome analysis by solid-phase isotope tagging and mass spectrometry
Zhou, H., Ranish, J. A., Watts, J. D., & Aebersold, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0502-512 · Cited by 384
Vickers, A. J., Savage, C., O'Brien, M. F., & Lilja, H. (2009) · Journal of Clinical Oncology · doi:10.1200/jco.2008.18.1685 · Cited by 254
Ultrasensitive, label-free, and real-time immunodetection using silicon field-effect transistors
Kim, A., Ah, C. S., Yu, H. Y., Yang, J.-H., Baek, I.-B., Ahn, C.-G., Park, C. W., Jun, M. S., & Lee, S. (2007) · Applied Physics Letters · doi:10.1063/1.2779965 · Cited by 250
Silicon Nanoribbons for Electrical Detection of Biomolecules
Elfström, N., Karlström, A. E., & Linnros, J. (2008) · Nano Letters · doi:10.1021/nl080094r · Cited by 185
Genomic Medicine and the Future of Health Care
Sander, C. (2000) · Science · doi:10.1126/science.287.5460.1977 · Cited by 176
Anomalous resonance in a nanomechanical biosensor
Gupta, A. K., Nair, P. R., Akin, D., Ladisch, M. R., Broyles, S., Alam, M. A., & Bashir, R. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602022103 · Cited by 160
Semiconducting Nanowire Field-Effect Transistor Biomolecular Sensors
Stern, E., Vacic, A., & Reed, M. A. (2008) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2008.2005168 · Cited by 146
Self-citationUehara, M., Kinoshita, T., Hojo, T., Akashi‐Tanaka, S., Iwamoto, E., & Fukutomi, T. (2008) · International Journal of Clinical Oncology · doi:10.1007/s10147-008-0773-3 · Cited by 135
Enzymes and related proteins as cancer biomarkers: A proteomic approach
Liang, S.-L., & Chan, D. W. (2007) · Clinica Chimica Acta · doi:10.1016/j.cca.2007.02.017 · Cited by 80
Protein Microarrays and Multiplexed Sandwich Immunoassays: What Beats the Beads?
Templin, M. F., Stoll, D., Bachmann, J., & Joos, T. O. (2004) · Combinatorial Chemistry & High Throughput Screening · doi:10.2174/1386207043328814 · Cited by 68
Handwerger, R. G., & Diamond, S. L. (2007) · Bioconjugate Chemistry · doi:10.1021/bc060280t · Cited by 22
Cited by
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
MoS2 Field-Effect Transistor for Next-Generation Label-Free Biosensors
Sarkar, D., Liu, W., Xie, X., Anselmo, A. C., Mitragotri, S., & Banerjee, K. (2014) · ACS Nano · doi:10.1021/nn5009148 · Cited by 1,047
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
SERS Nanoparticles in Medicine: From Label-Free Detection to Spectroscopic Tagging
Lane, L. A., Qian, X., & Nie, S. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00265 · Cited by 873
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Metadata
- Authors
- Stern, E., Vacic, A., Rajan, N. K., Criscione, J. M., Park, J., Ilic, B. R., Mooney, D. J., Reed, M. A., & Fahmy, T. M.
- Venue
- Nature Nanotechnology
- Published
- 2009-12-13
- Volume
- 5
- Issue
- 2
- Pages
- 138-142
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- OpenAlex
- W2023834245
- Cited by
- 543
- References
- 26
- FWCI
- 10.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.