The DOI matches its Crossref record; 101 of the 102 references it cites were found in a registry or an index.
Advancing the speed, sensitivity and accuracy of biomolecular detection using multi-length-scale engineering
Open accessAbstract
Rapid progress in identifying disease biomarkers has increased the importance of creating high-performance detection technologies. Over the last decade, the design of many detection platforms has focused on either the nano or micro length scale. Here, we review recent strategies that combine nano- and microscale materials and devices to produce large improvements in detection sensitivity, speed and accuracy, allowing previously undetectable biomarkers to be identified in clinical samples. Microsensors that incorporate nanoscale features can now rapidly detect disease-related nucleic acids expressed in patient samples. New microdevices that separate large clinical samples into nanocompartments allow precise quantitation of analytes, and microfluidic systems that utilize nanoscale binding events can detect rare cancer cells in the bloodstream more accurately than before. These advances will lead to faster and more reliable clinical diagnostic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These results highlight the unique advantages that these functionalized NPs possess for protein enrichment over antibody-based platforms: (a) comparable size and diffusion kinetics to proteins, promoting effective capture of low-abundance proteins within complex mixtures20,47,48; (b) high surface area per volume and high number of flexible binding sites, contributing to high ligand density and”
From Nanoproteomics enables proteoform-resolved analysis of low-abundance proteins in human serum (2020) · cites this paper as [20]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemistry and Properties of Nanocrystals of Different Shapes
Burda, C., Chen, X., Narayanan, R., & El-Sayed, M. A. (2005) · Chemical Reviews · doi:10.1021/cr030063a · Cited by 7,230
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Self-citationIsolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V. D., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S. R., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,595
Self-citationAllard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Circulating Breast Tumor Cells Exhibit Dynamic Changes in Epithelial and Mesenchymal Composition
Yu, M., Bardia, A., Wittner, B. S., Stott, S. L., Smas, M. E., Ting, D. T., Isakoff, S. J., Ciciliano, J. C., Wells, M. N., Shah, A. M., et al. (2013) · Science · doi:10.1126/science.1228522 · Cited by 2,476
Self-citationNanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,391
Self-citationMicrofluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,265
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119
Self-citationNanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,038
Self-citation
Flagged first, then by citations
1 of the 102 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 994
Self-citationA review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E. J., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 798
Ultrasensitive surface-enhanced Raman scattering detection in common fluids
Yang, S., Dai, X., Stogin, B. B., & Wong, T. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1518980113 · Cited by 703
Dai, Y., Somoza, R. A., Wang, L., Welter, J. F., Li, Y., Caplan, A. I., & Liu, C.-C. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201910772 · Cited by 667
Ultrasensitive detection of circulating exosomes with a 3D-nanopatterned microfluidic chip
Zhang, P., Zhou, X., He, M., Shang, Y., Tetlow, A. L., Godwin, A., & Zeng, Y. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0356-9 · Cited by 505
Metadata
- Authors
- Kelley, S. O., Mirkin, C. A., Walt, D. R., Ismagilov, R. F., Toner, M., & Sargent, E. H.
- Affiliations
- University of Toronto (CA)
- Northwestern University (US)
- Tufts University (US)
- California Institute of Technology (US)
- Harvard University (US)
- Corresponding author
- Kelley, Shana O.
- ORCID
- Venue
- Nature Nanotechnology
- Published
- 2014-12
- Volume
- 9
- Issue
- 12
- Pages
- 969-980
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- PMC
- PMC4472305
- OpenAlex
- W2082607189
- Cited by
- 398
- References
- 102
- Citations by year
- 2026: 11 · 2025: 22 · 2024: 23 · 2023: 26 · 2022: 43 · 2021: 24 · 2020: 44 · 2019: 38 · 2018: 48 · 2017: 42 · 2016: 40 · 2015: 37
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Nanotechnology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- CaltechAUTHORS (California Institute of Technology) (submittedVersion)
- Funders
- National Science Foundation
- U.S. Department of Defense (W81XWH1110814, W81XWH-11-1-, W81XWH, BC100510)
- Prostate Cancer Foundation
- Genome Canada
- National Institutes of Health (W81XWH)
- Defense Advanced Research Projects Agency (HR0011-11-2-0006)
- Advanced Research Projects Agency
- Canadian Institutes of Health Research
- National Institute of Biomedical Imaging and Bioengineering (R01EB012946, P41EB002503)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- biomolecule detection, disease biomarkers, nucleic acid detection, microsensors, nanocompartments, microfluidics, clinical diagnostics, detection sensitivity, sample separation
- MeSH terms
- Humans, Neoplasms, Biomarkers, Tumor, Biosensing Techniques, Nanotechnology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review