The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Wide-field, high-resolution Fourier ptychographic microscopy
Open accessAbstract
We report an imaging method, termed Fourier ptychographic microscopy (FPM), which iteratively stitches together a number of variably illuminated, low-resolution intensity images in Fourier space to produce a wide-field, high-resolution complex sample image. By adopting a wavefront correction strategy, the FPM method can also correct for aberrations and digitally extend a microscope's depth of focus beyond the physical limitations of its optics.As a demonstration, we built a microscope prototype with a half-pitch resolution of 0.78 µm, a field of view of ∼120 mm2 and a resolution-invariant depth of focus of 0.3 mm (characterized at 632 nm). Gigapixel colour images of histology slides verify successful FPM operation. The reported imaging procedure transforms the general challenge of high-throughput, high-resolution microscopy from one that is coupled to the physical limitations of the system's optics to one that is solvable through computation. A wide-field, high-resolution imaging scheme that offers enhanced depth of field is demonstrated. The approach relies on stitching together time-multiplexed images in Fourier space.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
Gustafsson, M. G. L. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00710.x · Cited by 3,786
Reconstruction of an object from the modulus of its Fourier transform
Fienup, J. R. (1978) · Optics Letters · doi:10.1364/ol.3.000027 · Cited by 1,836
High Dynamic Range Imaging: Acquisition, Display, and Image-Based Lighting
Reinhard, E., Ward, G., Pattanaik, S., Debevec, P. E., Heidrich, W., & Myszkowski, K. (2010) · Cited by 1,359
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Tyson, R. K. (2015) · CRC Press eBooks · doi:10.1201/b19712 · Cited by 864
Hard-X-Ray Lensless Imaging of Extended Objects
Rodenburg, J. M., Hurst, A. C., Cullis, A. G., Dobson, B. R., Pfeiffer, F., Bunk, O., David, C., Jefimovs, K., & Johnson, I. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.034801 · Cited by 855
Movable Aperture Lensless Transmission Microscopy: A Novel Phase Retrieval Algorithm
Faulkner, H. M. L., & Rodenburg, J. M. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.023903 · Cited by 839
Levoy, M., Ng, R., Adams, A., Footer, M., & Horowitz, M. (2006) · ACM Transactions on Graphics · doi:10.1145/1141911.1141976 · Cited by 730
Digital in-line holography for biological applications
Xu, W., Jericho, M. H., Meinertzhagen, I. A., & Kreuzer, H. J. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191361398 · Cited by 576
Phase retrieval with transverse translation diversity: a nonlinear optimization approach
Guizar-Sicairos, M., & Fienup, J. R. (2008) · Optics Express · doi:10.1364/oe.16.007264 · Cited by 525
Space–bandwidth product of optical signals and systems
Lohmann, A. W., Dorsch, R. G., Mendlovic, D., Ferreira, C., & Zalevsky, Z. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.000470 · Cited by 396
Tyson, R. (2010) · CRC Press eBooks · doi:10.1201/ebk1439808580 · Cited by 391
Multiscale gigapixel photography
Brady, D. J., Gehm, M. E., Stack, R. A., Marks, D. L., Kittle, D. S., Golish, D. R., Vera, E. M., & Feller, S. D. (2012) · Nature · doi:10.1038/nature11150 · Cited by 331
Synthetic Aperture Fourier Holographic Optical Microscopy
Alexandrov, S., Hillman, T. R., Gutzler, T., & Sampson, D. D. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.168102 · Cited by 286
Zheng, G., Lee, S. A., Antebi, Y., Elowitz, M. B., & Yang, C. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1110681108 · Cited by 209
Self-citationOptical ptychography: a practical implementation with useful resolution
Maiden, A. M., Rodenburg, J. M., & Humphry, M. J. (2010) · Optics Letters · doi:10.1364/ol.35.002585 · Cited by 180
Hillman, T. R., Gutzler, T., Alexandrov, S. A., & Sampson, D. D. (2009) · Optics Express · doi:10.1364/oe.17.007873 · Cited by 162
Inline hologram reconstruction with sparsity constraints
Denis, L., Lorenz, D. A., Thiébaut, É., Fournier, C., & Trede, D. (2009) · Optics Letters · doi:10.1364/ol.34.003475 · Cited by 145
Sub-pixel resolving optofluidic microscope for on-chip cell imaging
Zheng, G., Lee, S. A., Yang, S., & Yang, C. (2010) · Lab on a Chip · doi:10.1039/c0lc00213e · Cited by 145
Self-citationIncreased space-bandwidth product in pixel super-resolved lensfree on-chip microscopy
Greenbaum, A., Luo, W., Khademhosseinieh, B., Su, T., Coskun, A. F., & Özcan, A. (2013) · Scientific Reports · doi:10.1038/srep01717 · Cited by 144
Microscopy refocusing and dark-field imaging by using a simple LED array
Zheng, G., Kolner, C., & Yang, C. (2011) · Optics Letters · doi:10.1364/ol.36.003987 · Cited by 142
Self-citationOptical Design for Biomedical Imaging
Liang, R. (2010) · SPIE eBooks · doi:10.1117/3.871548 · Cited by 40
Wide field-of-view microscope based on holographic focus grid illumination
Wu, J., Cui, X., Zheng, G., Wang, Y. M., Lee, L. M., & Yang, C. (2010) · Optics Letters · doi:10.1364/ol.35.002188 · Cited by 34
Self-citation
Cited by
Phase recovery and holographic image reconstruction using deep learning in neural networks
Rivenson, Y., Zhang, Y., Günaydın, H., Teng, D., & Ozcan, A. (2017) · Light: Science & Applications · doi:10.1038/lsa.2017.141 · Cited by 1,059
On the use of deep learning for computational imaging
Barbastathis, G., Ozcan, A., & Situ, G. (2019) · Optica · doi:10.1364/optica.6.000921 · Cited by 869
Multiplexed coded illumination for Fourier Ptychography with an LED array microscope
Tian, L., Li, X., Ramchandran, K., & Waller, L. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002376 · Cited by 584
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Further improvements to the ptychographical iterative engine
Maiden, A., Johnson, D., & Li, P. (2017) · Optica · doi:10.1364/optica.4.000736 · Cited by 452
Metadata
- Authors
- Zheng, G., Horstmeyer, R., & Yang, C.
- Venue
- Nature Photonics
- Published
- 2013-07-28
- Volume
- 7
- Issue
- 9
- Pages
- 739-745
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W2047602908
- Cited by
- 1,829
- References
- 24
- FWCI
- 71.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.