The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Wide-field, high-resolution Fourier ptychographic microscopy
Open accessAbstract
We report an imaging method, termed Fourier ptychographic microscopy (FPM), which iteratively stitches together a number of variably illuminated, low-resolution intensity images in Fourier space to produce a wide-field, high-resolution complex sample image. By adopting a wavefront correction strategy, the FPM method can also correct for aberrations and digitally extend a microscope's depth of focus beyond the physical limitations of its optics.As a demonstration, we built a microscope prototype with a half-pitch resolution of 0.78 µm, a field of view of ∼120 mm2 and a resolution-invariant depth of focus of 0.3 mm (characterized at 632 nm). Gigapixel colour images of histology slides verify successful FPM operation. The reported imaging procedure transforms the general challenge of high-throughput, high-resolution microscopy from one that is coupled to the physical limitations of the system's optics to one that is solvable through computation. A wide-field, high-resolution imaging scheme that offers enhanced depth of field is demonstrated. The approach relies on stitching together time-multiplexed images in Fourier space.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
Gustafsson, M. G. L. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00710.x · Cited by 3,786
Reconstruction of an object from the modulus of its Fourier transform
Fienup, J. R. (1978) · Optics Letters · doi:10.1364/ol.3.000027 · Cited by 1,836
High Dynamic Range Imaging: Acquisition, Display, and Image-Based Lighting
Reinhard, E., Ward, G., Pattanaik, S., Debevec, P. E., Heidrich, W., & Myszkowski, K. (2010) · Cited by 1,359
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Tyson, R. K. (2015) · CRC Press eBooks · doi:10.1201/b19712 · Cited by 864
Hard-X-Ray Lensless Imaging of Extended Objects
Rodenburg, J. M., Hurst, A. C., Cullis, A. G., Dobson, B. R., Pfeiffer, F., Bunk, O., David, C., Jefimovs, K., & Johnson, I. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.034801 · Cited by 855
Movable Aperture Lensless Transmission Microscopy: A Novel Phase Retrieval Algorithm
Faulkner, H. M. L., & Rodenburg, J. M. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.023903 · Cited by 839
Levoy, M., Ng, R., Adams, A., Footer, M., & Horowitz, M. (2006) · ACM Transactions on Graphics · doi:10.1145/1141911.1141976 · Cited by 730
Digital in-line holography for biological applications
Xu, W., Jericho, M. H., Meinertzhagen, I. A., & Kreuzer, H. J. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191361398 · Cited by 576
Cited by
Phase recovery and holographic image reconstruction using deep learning in neural networks
Rivenson, Y., Zhang, Y., Günaydın, H., Teng, D., & Ozcan, A. (2017) · Light: Science & Applications · doi:10.1038/lsa.2017.141 · Cited by 1,059
On the use of deep learning for computational imaging
Barbastathis, G., Ozcan, A., & Situ, G. (2019) · Optica · doi:10.1364/optica.6.000921 · Cited by 869
Multiplexed coded illumination for Fourier Ptychography with an LED array microscope
Tian, L., Li, X., Ramchandran, K., & Waller, L. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002376 · Cited by 584
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Further improvements to the ptychographical iterative engine
Maiden, A., Johnson, D., & Li, P. (2017) · Optica · doi:10.1364/optica.4.000736 · Cited by 452
Embedded pupil function recovery for Fourier ptychographic microscopy
Ou, X., Zheng, G., & Yang, C. (2014) · Optics Express · doi:10.1364/oe.22.004960 · Cited by 443
Self-citationConcept, implementations and applications of Fourier ptychography
Zheng, G., Shen, C., Jiang, S., Song, P., & Yang, C. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00280-y · Cited by 416
Self-citationFourier-space Diffractive Deep Neural Network
Yan, T., Wu, J., Zhou, T., Xie, H., Xu, F., Fan, J., Fang, L., Lin, X., & Dai, Q. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.023901 · Cited by 408
Quantitative differential phase contrast imaging in an LED array microscope
Tian, L., & Waller, L. (2015) · Optics Express · doi:10.1364/oe.23.011394 · Cited by 392
Rivenson, Y., Liu, T., Wei, Z., Zhang, Y., de Haan, K., & Ozcan, A. (2019) · Light: Science & Applications · doi:10.1038/s41377-019-0129-y · Cited by 392
Whole slide imaging in pathology: advantages, limitations, and emerging perspectives
Pantanowitz, L., Farahani, N., & Parwani, A. (2015) · Pathology and Laboratory Medicine International · doi:10.2147/plmi.s59826 · Cited by 373
Experimental robustness of Fourier ptychography phase retrieval algorithms
Yeh, L.-H., Dong, J., Zhong, J., Tian, L., Chen, M., Tang, G., Soltanolkotabi, M., & Waller, L. (2015) · Optics Express · doi:10.1364/oe.23.033214 · Cited by 320
Single-shot quantitative phase gradient microscopy using a system of multifunctional metasurfaces
Kwon, H., Arbabi, E., Kamali, S. M., Faraji-Dana, M., & Faraon, A. (2020) · Nature Photonics · doi:10.1038/s41566-019-0536-x · Cited by 319
Computational illumination for high-speed in vitro Fourier ptychographic microscopy
Tian, L., Liu, Z., Yeh, L.-H., Chen, M., Zhong, J., & Waller, L. (2015) · Optica · doi:10.1364/optica.2.000904 · Cited by 317
Wasisto, H. S., Prades, J. D., Gülink, J., & Waag, A. (2019) · Applied Physics Reviews · doi:10.1063/1.5096322 · Cited by 309
Wavefront shaping with disorder-engineered metasurfaces
Jang, M., Horie, Y., Shibukawa, A., Brake, J., Liu, Y., Kamali, S. M., Arbabi, A., Ruan, H., Faraon, A., & Yang, C. (2018) · Nature Photonics · doi:10.1038/s41566-017-0078-z · Cited by 289
Self-citationMait, J. N., Euliss, G. W., & Athale, R. A. (2018) · Advances in Optics and Photonics · doi:10.1364/aop.10.000409 · Cited by 289
Compressive Phase Retrieval via Generalized Approximate Message Passing
Schniter, P., & Rangan, S. (2015) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2014.2386294 · Cited by 279
Quantitative phase imaging based on holography: trends and new perspectives
Huang, Z., & Cao, L. (2024) · Light: Science & Applications · doi:10.1038/s41377-024-01453-x · Cited by 277
Deep learning approach for Fourier ptychography microscopy
Nguyen, T., Xue, Y., Li, Y., Tian, L., & Nehmetallah, G. (2018) · Optics Express · doi:10.1364/oe.26.026470 · Cited by 261
Synthetic aperture-based on-chip microscopy
Luo, W., Greenbaum, A., Zhang, Y., & Ozcan, A. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.34 · Cited by 257
Reliable deep-learning-based phase imaging with uncertainty quantification
Xue, Y., Cheng, S., Li, Y., & Tian, L. (2019) · Optica · doi:10.1364/optica.6.000618 · Cited by 198
“Second, we enhance the resolution following the principles of synthetic aperture [19] and Fourier ptychographic microscopy (FPM) [6] by using oblique illumination to introduce high frequency information that are beyond the objective lens’s native passband into the measurements.”
BackgroundMethodInfluential
Metadata
- Authors
- Zheng, G., Horstmeyer, R., & Yang, C.
- Venue
- Nature Photonics
- Published
- 2013-07-28
- Volume
- 7
- Issue
- 9
- Pages
- 739-745
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W2047602908
- Cited by
- 1,829
- References
- 24
- FWCI
- 71.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.