Reliability and Intermethod Agreement for Body Fat Assessment Among Two Field and Two Laboratory Methods in Adolescents

Vicente‐Rodríguez, Germán, Rey‐López, Juan P., Mesana, Maria I., Poortvliet, Eric, Ortega, Francisco B., Polito, Angela, Nagy, Eniko, Widhalm, Kurt +3 more·2012·Obesity

Abstract

To increase knowledge about reliability and intermethods agreement for body fat (BF) is of interest for assessment, interpretation, and comparison purposes. It was aimed to examine intra- and inter-rater reliability, interday variability, and degree of agreement for BF using air-displacement plethysmography (Bod-Pod), dual-energy X-ray absorptiometry (DXA), bioelectrical impedance analysis (BIA), and skinfold measurements in European adolescents. Fifty-four adolescents (25 females) from Zaragoza and 30 (14 females) from Stockholm, aged 13-17 years participated in this study. Two trained raters in each center assessed BF with Bod-Pod, DXA, BIA, and anthropometry (DXA only in Zaragoza). Intermethod agreement and reliability were studied using a 4-way ANOVA for the same rater on the first day and two additional measurements on a second day, one each rater. Technical error of measurement (TEM) and percentage coefficient of reliability (%R) were also reported. No significant intrarater, inter-rater, or interday effect was observed for %BF for any method in either of the cities. In Zaragoza, %BF was significantly different when measured by Bod-Pod and BIA in comparison with anthropometry and DXA (all P < 0.001). The same result was observed in Stockholm (P < 0.001), except that DXA was not measured. Bod-Pod, DXA, BIA, and anthropometry are reliable for %BF repeated assessment within the same day by the same or different raters or in consecutive days by the same rater. Bod-Pod showed close agreement with BIA as did DXA with anthropometry; however, Bod-Pod and BIA presented higher values of %BF than anthropometry and DXA.

Integrity signals

Registry

Crossref · 10.1038/oby.2011.272

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Vicente‐Rodríguez, G., Rey‐López, J. P., Mesana, M. I., Poortvliet, E., Ortega, F. B., Polito, A., Nagy, E., Widhalm, K., Sjöström, M., Moreno, L. A., & On Behalf of the HELENA Study Group
Affiliations
  • Universidad de Zaragoza (ES)
  • Karolinska Institutet (SE)
  • Universidad de Granada (ES)
  • Istituto Nazionale di Ricerca per gli Alimenti e la Nutrizione (IT)
  • Medical University of Vienna (AT)
Venue
Obesity
Publisher
Wiley
Published
2012-01
Volume
20
Issue
1
Pages
221-228
ISSN
  • 1930-7381 (ISSN-L)
  • 1930-739X
OpenAlex
W1968665320
Cited by
79
References
42
Citations by year
2026: 4 · 2025: 1 · 2024: 7 · 2023: 3 · 2022: 2 · 2021: 10 · 2020: 13 · 2019: 4 · 2018: 2 · 2017: 9 · 2016: 6 · 2015: 3 · 2014: 6 · 2013: 7 · 2012: 2
FWCI
3.27
Type
journal article
Language
en
Open access
closed
Locations
  • Obesity (publishedVersion)
  • PubMed (publishedVersion)
  • Lirias (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Obesity, Physical Activity, Diet
Keywords
body fat measurement, body composition, adolescents, inter-method agreement, reliability statistics, air displacement plethysmography, dual-energy X-ray absorptiometry, bioelectrical impedance analysis, skinfold thickness, anthropometry, technical error of measurement
MeSH terms
Adipose Tissue, Adolescent, Analysis of Variance, Body Composition, Cross-Sectional Studies, Female, Humans, Male, Plethysmography, Skinfold Thickness, Sweden, Reproducibility of Results, Absorptiometry, Photon, Body Mass Index, Electric Impedance, White People

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review