Single-photon avalanche diode imagers in biophotonics: review and outlook
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
Single-photon avalanche diode (SPAD) arrays are solid-state detectors that offer imaging capabilities at the level of individual photons, with unparalleled photon counting and time-resolved performance. This fascinating technology has progressed at a very fast pace in the past 15 years, since its inception in standard CMOS technology in 2003. A host of architectures have been investigated, ranging from simpler implementations, based solely on off-chip data processing, to progressively “smarter” sensors including on-chip, or even pixel level, time-stamping and processing capabilities. As the technology has matured, a range of biophotonics applications have been explored, including (endoscopic) FLIM, (multibeam multiphoton) FLIM-FRET, SPIM-FCS, super-resolution microscopy, time-resolved Raman spectroscopy, NIROT and PET. We will review some representative sensors and their corresponding applications, including the most relevant challenges faced by chip designers and end-users. Finally, we will provide an outlook on the future of this fascinating technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Infrared and Raman Spectroscopy
(1975) · Elsevier eBooks · doi:10.1016/b978-0-12-182552-2.x5001-3 · Cited by 5,474
Beiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung
Abbe, E. (1873) · Archiv für Mikroskopische Anatomie · doi:10.1007/bf02956173 · Cited by 2,724
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Microscopy and its focal switch
Hell, S. W. (2009) · Nature Methods · doi:10.1038/nmeth.1291 · Cited by 986
Fluorescence resonance energy transfer
Clegg, R. M. (1995) · Current Opinion in Biotechnology · doi:10.1016/0958-1669(95)80016-6 · Cited by 929
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Measuring image resolution in optical nanoscopy
Nieuwenhuizen, R. P. J., Lidke, K. A., Bates, M., Puig, D. L., Grünwald, D., Stallinga, S., & Rieger, B. (2013) · Nature Methods · doi:10.1038/nmeth.2448 · Cited by 800
Fluorescence nanoscopy by ground-state depletion and single-molecule return
Fölling, J., Bossi, M., Bock, H., Medda, R., Wurm, C. A., Hein, B., Jakobs, S., Eggeling, C., & Hell, S. W. (2008) · Nature Methods · doi:10.1038/nmeth.1257 · Cited by 758
Video-rate nanoscopy using sCMOS camera–specific single-molecule localization algorithms
Huang, F., Hartwich, T. M. P., Rivera-Molina, F. E., Lin, Y., Duim, W. C., Long, J. J., Uchil, P. D., Myers, J. R., Baird, M. A., Mothes, W., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2488 · Cited by 526
Lakowicz, J. R., Szmacinski, H., Nowaczyk, K., Berndt, K. W., & Johnson, M. (1992) · Analytical Biochemistry · doi:10.1016/0003-2697(92)90112-k · Cited by 446
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Design and characterization of a CMOS 3-D image sensor based on single photon avalanche diodes
Niclass, C., Rochas, A., Besse, P.-A., & Edoardo Charbon, A. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.848173 · Cited by 379
Principles and features of single-photon avalanche diode arrays
Zappa, F., Tisa, S., Tosi, A., & Cova, S. (2007) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2007.06.021 · Cited by 329
Fluorescence lifetime imaging (FLIM): Basic concepts and some recent developments
Suhling, K., Hirvonen, L. M., Levitt, J. A., Chung, P.-H., Tregidgo, C., Le Marois, A., Rusakov, D. A., Zheng, K., Ameer-Beg, S., Poland, S., et al. (2015) · Medical Photonics · doi:10.1016/j.medpho.2014.12.001 · Cited by 313
Fluorescence Lifetime Techniques in Medical Applications
Marcu, L. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0495-y · Cited by 257
Zhang, C., Lindner, S., Antolovic, I. M., Mata Pavia, J., Wolf, M., & Charbon, E. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2883720 · Cited by 246
Self-citationRochas, A., Gani, M., Furrer, B., Besse, P. A., Popovic, R. S., Ribordy, G., & Gisin, N. (2003) · Review of Scientific Instruments · doi:10.1063/1.1584083 · Cited by 224
A 512 × 512 SPAD Image Sensor With Integrated Gating for Widefield FLIM
Ulku, A. C., Bruschini, C., Antolovic, I. M., Kuo, Y., Ankri, R., Weiss, S., Michalet, X., & Charbon, E. (2019) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2018.2867439 · Cited by 201
Self-citationBraga, L. H. C., Gasparini, L., Grant, L., Henderson, R. K., Massari, N., Perenzoni, M., Stoppa, D., & Walker, R. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284351 · Cited by 195
Imaging fluorescence (cross-) correlation spectroscopy in live cells and organisms
Krieger, J., Singh, A. P., Bag, N., Garbe, C. S., Saunders, T. E., Langowski, J., & Wohland, T. (2015) · Nature Protocols · doi:10.1038/nprot.2015.100 · Cited by 187
Optimizing Imaging Conditions for Demanding Multi-Color Super Resolution Localization Microscopy
Nahidiazar, L., Agronskaia, A. V., Broertjes, J., van den Broek, B., & Jalink, K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0158884 · Cited by 183
Development of deep subsurface Raman spectroscopy for medical diagnosis and disease monitoring
Matousek, P., & Stone, N. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00466g · Cited by 169
Raman and coherent anti-Stokes Raman scattering microspectroscopy for biomedical applications
Krafft, C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.4.040801 · Cited by 165
A 100 fps, Time-Correlated Single-Photon-Counting-Based Fluorescence-Lifetime Imager in 130 nm CMOS
Field, R. M., Realov, S., & Shepard, K. L. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2293777 · Cited by 163
Fluorescence suppression in Raman spectroscopy using a time-gated CMOS SPAD
Kostamovaara, J., Tenhunen, J., Kögler, M., Nissinen, I., Nissinen, J., & Keränen, P. (2013) · Optics Express · doi:10.1364/oe.21.031632 · Cited by 156
First fully integrated 2-D array of single-photon detectors in standard CMOS technology
Rochas, A., Gösch, M., Serov, A., Besse, P.-A., Popovic, R. S., Lasser, T., & Rigler, R. W. (2003) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2003.813387 · Cited by 154
Architecture and applications of a high resolution gated SPAD image sensor
Burri, S., Maruyama, Y., Michalet, X., Regazzoni, F., Bruschini, C. E., & Charbon, E. (2014) · Optics Express · doi:10.1364/oe.22.017573 · Cited by 143
Self-citationPoland, S. P., Krstajić, N., Monypenny, J., Coelho, S., Tyndall, D., Walker, R., Devauges, V., Richardson, J. A., Dutton, N. A. W., Barber, P. R., et al. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.000277 · Cited by 125
Wide-field TCSPC: methods and applications
Hirvonen, L. M., & Suhling, K. (2016) · Measurement Science and Technology · doi:10.1088/1361-6501/28/1/012003 · Cited by 124
Towards next-generation time-domain diffuse optics for extreme depth penetration and sensitivity
Mora, A. D. D., Contini, D., Arridge, S., Martelli, F., Tosi, A., Boso, G., Farina, A., Durduran, T., Martinenghi, E., Torricelli, A. M., et al. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001749 · Cited by 121
Li, D. D.-U., Arlt, J., Richardson, J. A., Walker, R., Buts, A., Stoppa, D., Edoardo Charbon, A., & Henderson, R. (2010) · Optics Express · doi:10.1364/oe.18.010257 · Cited by 120
A Single-Photon Avalanche Diode Array for Fluorescence Lifetime Imaging Microscopy
Schwartz, D. E., Edoardo Charbon, A., & Shepard, K. L. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2005818 · Cited by 113
Development of new photon-counting detectors for single-molecule fluorescence microscopy
Michalet, X., Colyer, R. A., Scalia, G., Ingargiola, A., Lin, R. R., Millaud, J. E., Weiss, S., Siegmund, O. H. W., Tremsin, A. S., Vallerga, J. V., et al. (2012) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2012.0035 · Cited by 111
Maruyama, Y., Blacksberg, J., & Charbon, E. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2282091 · Cited by 104
Self-citationGyöngy, I., Calder, N. J., Davies, A., Dutton, N. A. W., Duncan, R. R., Rickman, C., Dalgarno, P. A., & Henderson, R. (2017) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2017.2779790 · Cited by 104
Advances in digital SiPMs and their application in biomedical imaging
Schaart, D. R., Edoardo Charbon, A., Frach, T., & Schulz, V. (2015) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2015.10.078 · Cited by 101
SPAD Image Sensor With Analog Counting Pixel for Time-Resolved Fluorescence Detection
Pancheri, L., Massari, N., & Stoppa, D. (2013) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2013.2276752 · Cited by 93
Pavia, J. M., Wolf, M., & Charbon, E. (2014) · Optics Express · doi:10.1364/oe.22.004202 · Cited by 85
Self-citationFluorescence Lifetime Imaging, a New Tool in Confocal Microscopy
Draaijer, A., Sanders, R., & Gerritsen, H. C. (1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6_31 · Cited by 83
Parallel single molecule detection with a fully integrated single-photon 2×2 CMOS detector array
Gösch, M., Serov, A., Rochas, A., Blom, H., Anhut, T., Besse, P.-A., Popović, R. S., Lasser, T., & Rigler, R. W. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1781668 · Cited by 77
Stuker, F., Baltes, C., Dikaiou, K., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2112669 · Cited by 76
A sub-ns time-gated CMOS single photon avalanche diode detector for Raman spectroscopy
Nissinen, I., Nissinen, J., Lansman, A.-K., Hallman, L. W., Kilpelä, A., Kostamovaara, J., Kögler, M., Aikio, M., & Tenhunen, J. (2011) · European Solid-State Device Research Conference · doi:10.1109/essderc.2011.6044156 · Cited by 72
Wang, Y., Zhang, Y., Hu, W. H., Xie, S.-T., Gong, C., Iqbal, K., & Liu, F. (2016) · Scientific Reports · doi:10.1038/srep17241 · Cited by 70
Rojalin, T., Kurki, L., Laaksonen, T., Viitala, T., Kostamovaara, J., Gordon, K. C., Galvis, L., Wachsmann-Hogiu, S., Strachan, C. J., & Yliperttula, M. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-9156-6 · Cited by 63
Silicon Photomultipliers and SPAD imagers in biophotonics: Advances and perspectives
Caccia, M., Nardo, L., Santoro, R., & Schaffhauser, D. (2018) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2018.10.204 · Cited by 58
Fast single-photon avalanche diode arrays for laser Raman spectroscopy
Blacksberg, J., Maruyama, Y., Charbon, E., & Rossman, G. R. (2011) · Optics Letters · doi:10.1364/ol.36.003672 · Cited by 50
Self-citationNissinen, I., Nissinen, J., Keränen, P., Stoppa, D., & Kostamovaara, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2813531 · Cited by 47
Geiger-Mode Avalanche Photodiode Arrays Integrated to All-Digital CMOS Circuits
Aull, B. F. (2016) · Sensors · doi:10.3390/s16040495 · Cited by 46
Alayed, M., & Deen, M. J. (2017) · Sensors · doi:10.3390/s17092115 · Cited by 44
Time-resolved multifocal multiphoton microscope for high speed FRET imaging in vivo
Poland, S. P., Krstajić, N., Coelho, S., Tyndall, D., Walker, R., Devauges, V., Morton, P. E., Nicholas, N. S., Richardson, J. A., Li, D., et al. (2014) · Optics Letters · doi:10.1364/ol.39.006013 · Cited by 43
Intermite, G., McCarthy, A., Warburton, R. E., Ren, X., Villa, F., Lussana, R., Waddie, A. J., Taghizadeh, M. R., Tosi, A., Zappa, F., et al. (2015) · Optics Express · doi:10.1364/oe.23.033777 · Cited by 42
Antolović, I. M., Burri, S., Bruschini, C. E., Hoebe, R. A., & Edoardo Charbon, A. (2017) · Scientific Reports · doi:10.1038/srep44108 · Cited by 42
Self-citationUnternährer, M., Bessire, B., Gasparini, L., Stoppa, D., & Stefanov, A. (2016) · Optics Express · doi:10.1364/oe.24.028829 · Cited by 36
A $2\times (4)\times 128$ Multitime-Gated SPAD Line Detector for Pulsed Raman Spectroscopy
Nissinen, I., Nissinen, J., Keränen, P., Lansman, A.-K., Holma, J., & Kostamovaara, J. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2361610 · Cited by 34
Unternährer, M., Bessire, B., Gasparini, L., et al. (2016) · Bern Open Repository and Information System (University of Bern) · Cited by 34
Multipixel single-photon avalanche diode array for parallel photon counting applications
Rech, I., Marangoni, S., Resnati, D., Ghioni, M., & Cova, S. (2008) · Journal of Modern Optics · doi:10.1080/09500340802318309 · Cited by 30
Gasparini, L., Zarghami, M., Xu, H., Parmesan, L., Moreno-García, M., Unternährer, M., Bessire, B., Stefanov, A., Stoppa, D., & Perenzoni, M. (2018) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2018.8310202 · Cited by 29
Multispot single-molecule FRET: High-throughput analysis of freely diffusing molecules
Ingargiola, A., Lerner, E., Chung, S., Panzeri, F., Gulinatti, A., Rech, I., Ghioni, M., Weiss, S., & Michalet, X. (2017) · PLoS ONE · doi:10.1371/journal.pone.0175766 · Cited by 28
Nissinen, I., Lansman, A.-K., Nissinen, J., Holma, J., & Kostamovaara, J. (2013) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc.2013.6649130 · Cited by 20
A quantum imager for intensity correlated photons
Boïko, D. L., Günther, N. J., Bräuer, N., Sergio, M., Niclass, C., Beretta, G. B., & Edoardo Charbon, A. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/1/013001 · Cited by 13
High intensity click statistics from a 10 × 10 avalanche photodiode array
Kröger, J., Ahrens, T. J., Sperling, J., Vogel, W., Stolz, H., & Hage, B. (2017) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/1361-6455/aa8e68 · Cited by 12
Boïko, D. L., Günther, N. J., Brauer, N., Sergio, M., Niclass, C., Beretta, G. B., & Edoardo Charbon, A. (2009) · Optics Express · doi:10.1364/oe.17.015087 · Cited by 6
Cited by
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 880
Megapixel time-gated SPAD image sensor for 2D and 3D imaging applications
Morimoto, K., Ardelean, A., Wu, M.-L., Ulku, A. C., Antolovic, I. M., Bruschini, C., & Charbon, E. (2020) · Optica · doi:10.1364/optica.386574 · Cited by 342
Self-citationSingle-photon detection for long-range imaging and sensing
Hadfield, R. H., Leach, J., Fleming, F., Paul, D. J., Tan, C. H., Ng, J. S., Henderson, R. K., & Buller, G. S. (2023) · Optica · doi:10.1364/optica.488853 · Cited by 218
Time-gated Raman spectroscopy – a review
Kögler, M., & Heilala, B. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/abb044 · Cited by 107
Imaging and certifying high-dimensional entanglement with a single-photon avalanche diode camera
Ndagano, B., Defienne, H., Lyons, A., Starshynov, I., Villa, F., Tisa, S., & Faccio, D. (2020) · npj Quantum Information · doi:10.1038/s41534-020-00324-8 · Cited by 76
Metadata
- Authors
- Bruschini, C., Homulle, H., Antolovic, I. M., Burri, S., & Charbon, E.
- Venue
- Light: Science & Applications
- Published
- 2019-09-18
- Volume
- 8
- Issue
- 1
- Pages
- 87-87
- ISSN
- 2047-7538 (ISSN-L)
- OpenAlex
- W2973538687
- Cited by
- 512
- References
- 62
- FWCI
- 38.50
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.