Microclot array elastometry for integrated measurement of thrombus formation and clot biomechanics under fluid shear
Open accessThe DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Abstract
Blood clotting at the vascular injury site is a complex process that involves platelet adhesion and clot stiffening/contraction in the milieu of fluid flow. An integrated understanding of the hemodynamics and tissue mechanics regulating this process is currently lacking due to the absence of an experimental system that can simultaneously model clot formation and measure clot mechanics under shear flow. Here we develop a microfluidic-integrated microclot-array-elastometry system (clotMAT) that recapitulates dynamic changes in clot mechanics under physiological shear. Treatments with procoagulants and platelet antagonists and studies with diseased patient plasma demonstrate the ability of the system to assay clot biomechanics associated with common antiplatelet treatments and bleeding disorders. The changes of clot mechanics under biochemical treatments and shear flow demonstrate independent yet equally strong effects of these two stimulants on clot stiffening. This microtissue force sensing system may have future research and diagnostic potential for various bleeding disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In our prior work (50–53), we documented that fibroblast-populated microtissues exhibit a stiffness of 5 kPa, aligning with the stiffness of physiologically soft PDMS.”
From Modeling mechanical activation of macrophages during pulmonary fibrogenesis for targeted anti-fibrosis therapy (2024) · cites this paper as [51]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear elasticity in biological gels
Storm, C., Pastore, J. J., MacKintosh, F. C., Lubensky, T. C., & Janmey, P. A. (2005) · Nature · doi:10.1038/nature03521 · Cited by 1,703
Ruggeri, Z. M. (2002) · Nature Medicine · doi:10.1038/nm1102-1227 · Cited by 1,589
Initiation of Platelet Adhesion by Arrest onto Fibrinogen or Translocation on von Willebrand Factor
Savage, B., Saldívar, E., & Ruggeri, Z. M. (1996) · Cell · doi:10.1016/s0092-8674(00)80983-6 · Cited by 1,196
FEBio: Finite Elements for Biomechanics
Maas, S. A., Ellis, B. J., Ateshian, G. A., & Weiss, J. A. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4005694 · Cited by 1,105
A shear gradient–dependent platelet aggregation mechanism drives thrombus formation
Nesbitt, W. S., Westein, E., Tovar-Lopez, F. J., Tolouei, E., Mitchell, A., Fu, J., Carberry, J., Fouras, A., & Jackson, S. P. (2009) · Nature Medicine · doi:10.1038/nm.1955 · Cited by 862
The growing complexity of platelet aggregation
Jackson, S. P. (2007) · Blood · doi:10.1182/blood-2006-12-027698 · Cited by 737
Multi-centre investigation on reference ranges for ROTEM thromboelastometry
Lang, T., Bauters, A., Braun, S. L., Pötzsch, B., von Pape, K.-W., Kolde, H.-J., & Lakner, M. (2005) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000169225.31173.19 · Cited by 503
Microfabricated tissue gauges to measure and manipulate forces from 3D microtissues
Legant, W. R., Pathak, A., Yang, M. T., Deshpande, V. S., McMeeking, R. M., & Chen, C. S. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900174106 · Cited by 434
Stalker, T. J., Traxler, E. A., Wu, J., Wannemacher, K. M., Cermignano, S. L., Voronov, R., Diamond, S. L., & Brass, L. F. (2013) · Blood · doi:10.1182/blood-2012-09-457739 · Cited by 427
Boudou, T., Legant, W. R., Mu, A., Borochin, M. A., Thavandiran, N., Radisic, M., Zandstra, P. W., Epstein, J. A., Margulies, K. B., & Chen, C. S. (2012) · Tissue Engineering Part A · doi:10.1089/ten.tea.2011.0341 · Cited by 413
Bolliger, D., Seeberger, M. D., & Tanaka, K. A. (2012) · Transfusion Medicine Reviews · doi:10.1016/j.tmrv.2011.07.005 · Cited by 397
Mechanics and contraction dynamics of single platelets and implications for clot stiffening
Lam, W. A., Chaudhuri, O., Crow, A., Webster, K. D., Li, T.-D., Kita, A., Huang, J., & Fletcher, D. A. (2011) · Nature Materials · doi:10.1038/nmat2903 · Cited by 349
Heath, K. E., Campos-Barros, A., Toren, A., Rozenfeld-Granot, G., Carlsson, L. E., Savige, J., Denison, J. C., Gregory, M. C., White, J. G., Barker, D. F., et al. (2001) · The American Journal of Human Genetics · doi:10.1086/324267 · Cited by 304
Formation and optogenetic control of engineered 3D skeletal muscle bioactuators
Sakar, M. S., Neal, D., Boudou, T., Borochin, M. A., Li, Y., Weiss, R., Kamm, R. D., Chen, C. S., & Asada, H. H. (2012) · Lab on a Chip · doi:10.1039/c2lc40338b · Cited by 288
Design and formulation of functional pluripotent stem cell-derived cardiac microtissues
Thavandiran, N., Dubois, N., Mikryukov, A., Massé, S., Beca, B., Simmons, C. A., Deshpande, V. S., McGarry, J. P., Chen, C. S., Nanthakumar, K., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1311120110 · Cited by 285
Shankaran, H., Alexandridis, P., & Neelamegham, S. (2003) · Blood · doi:10.1182/blood-2002-05-1550 · Cited by 231
Self-citationQiu, Y., Brown, A. C., Myers, D. R., Sakurai, Y., Mannino, R. G., Tran, R., Ahn, B., Hardy, E. T., Kee, M. F., Kumar, S., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1322917111 · Cited by 213
Kang, H., Wen, Q., Janmey, P. A., Tang, J. X., Conti, E., & MacKintosh, F. C. (2009) · The Journal of Physical Chemistry B · doi:10.1021/jp807749f · Cited by 194
Mechanical Characterization of Thromboemboli in Acute Ischemic Stroke and Laboratory Embolus Analogs
Chueh, J. Y., Wakhloo, A. K., Hendricks, G. H., Silva, C. F., Weaver, J. P., & Gounis, M. J. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2485 · Cited by 191
Inner clot diffusion and permeation during fibrinolysis
Diamond, S. L., & Anand, S. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81314-6 · Cited by 181
Cells Actively Stiffen Fibrin Networks by Generating Contractile Stress
Jansen, K. A., Bacabac, R. G., Piechocka, I. K., & Koenderink, G. H. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.10.008 · Cited by 175
Quantitative structural mechanobiology of platelet-driven blood clot contraction
Kim, O. V., Litvinov, R. I., Alber, M. S., & Weisel, J. W. (2017) · Nature Communications · doi:10.1038/s41467-017-00885-x · Cited by 168
Microfluidic devices for studies of shear-dependent platelet adhesion
Gutierrez, E., Petrich, B. G., Shattil, S. J., Ginsberg, M. H., Groisman, A., & Kasirer-Friede, A. (2008) · Lab on a Chip · doi:10.1039/b804795b · Cited by 148
Ono, A., Westein, E., Hsiao, S., Nesbitt, W. S., Hamilton, J. R., Schoenwaelder, S. M., & Jackson, S. P. (2008) · Blood · doi:10.1182/blood-2007-12-127001 · Cited by 145
Fibrotic microtissue array to predict anti-fibrosis drug efficacy
Asmani, M., Velumani, S., Li, Y., Wawrzyniak, N., Hsia, I., Chen, Z., Hinz, B., & Zhao, R. (2018) · Nature Communications · doi:10.1038/s41467-018-04336-z · Cited by 137
Self-citationNeeves, K. B., Illing, D. A. R., & Diamond, S. L. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2009.12.4275 · Cited by 134
Tovar-Lopez, F. J., Rosengarten, G., Westein, E., Khoshmanesh, K., Jackson, S. P., Mitchell, A., & Nesbitt, W. S. (2009) · Lab on a Chip · doi:10.1039/b916757a · Cited by 132
Single-platelet nanomechanics measured by high-throughput cytometry
Myers, D. R., Qiu, Y., Fay, M. E., Tennenbaum, M., Chester, D., Cuadrado, J., Sakurai, Y., Baek, J., Tran, R., Ciciliano, J. C., et al. (2016) · Nature Materials · doi:10.1038/nmat4772 · Cited by 126
Cellular forces and matrix assembly coordinate fibrous tissue repair
Sakar, M. S., Eyckmans, J., Pieters, R., Eberli, D., Nelson, B. J., & Chen, C. S. (2016) · Nature Communications · doi:10.1038/ncomms11036 · Cited by 125
Role of fluid shear stress in regulating VWF structure, function and related blood disorders
Gogia, S., & Neelamegham, S. (2016) · Biorheology · doi:10.3233/bir-15061 · Cited by 112
Self-citationA Mechanistic Model of Acute Platelet Accumulation in Thrombogenic Stenoses
Wootton, D. M., Markou, C. P., Hanson, S. R., & Ku, D. N. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1359449 · Cited by 111
Muthard, R. W., & Diamond, S. L. (2012) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.112.300312 · Cited by 110
Zhao, R., Boudou, T., Wang, W., Chen, C. S., & Reich, D. H. (2013) · Advanced Materials · doi:10.1002/adma.201203585 · Cited by 106
Self-citationPlatelet retraction force measurements using flexible post force sensors
Liang, X. M., Han, S. J., Reems, J., Gao, D. Y., & Sniadecki, N. J. (2010) · Lab on a Chip · doi:10.1039/b918719g · Cited by 94
The structural properties and contractile force of a clot
Jen, C. J., & McIntire, L. V. (1982) · Cell Motility · doi:10.1002/cm.970020504 · Cited by 87
Enigmas of Blood Clot Elasticity
Weisel, J. W. (2008) · Science · doi:10.1126/science.1154210 · Cited by 86
Regulating thrombus growth and stability to achieve an optimal response to injury
Brass, L. F., Wannemacher, K. M., Ma, P., & Stalker, T. J. (2011) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2011.04364.x · Cited by 81
Local and global deformations in a strain-stiffening fibrin gel
Wen, Q., Basu, A., Winer-Jones, J. P., Yodh, A. G., & Janmey, P. A. (2007) · New Journal of Physics · doi:10.1088/1367-2630/9/11/428 · Cited by 80
Elastic Behavior and Platelet Retraction in Low- and High-Density Fibrin Gels
Wufsus, A. R., Rana, K., Brown, A., Dorgan, J. R., Liberatore, M. W., & Neeves, K. B. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2014.11.007 · Cited by 75
Solution Structure of Human von Willebrand Factor Studied Using Small Angle Neutron Scattering
Singh, I., Shankaran, H., Beauharnois, M. E., Xiao, Z., Alexandridis, P., & Neelamegham, S. (2006) · Journal of Biological Chemistry · doi:10.1074/jbc.m607123200 · Cited by 62
Self-citationZhao, R., Chen, C. S., & Reich, D. H. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.02.020 · Cited by 61
Self-citationBlinc, A., Keber, D., Lahajnar, G., Stegnar, M., Zidanšek, A., & Demšar, F. (1992) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1646341 · Cited by 46
Application of microfluidic devices in studies of thrombosis and hemostasis
Zhang, C., & Neelamegham, S. (2017) · Platelets · doi:10.1080/09537104.2017.1319047 · Cited by 45
Self-citationLi, R., Fries, S., Li, X., Großer, T., & Diamond, S. L. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.198101 · Cited by 42
Ateshian, G. A., Costa, K. D., Azeloglu, E. U., Morrison, B., & Hung, C. T. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3192138 · Cited by 38
Analysis of Morphology of Platelet Aggregates Formed on Collagen Under Laminar Blood Flow
Colace, T. V., Falls, E. M., Zheng, X. L., & Diamond, S. L. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0182-4 · Cited by 37
Lung Microtissue Array to Screen the Fibrogenic Potential of Carbon Nanotubes
Chen, Z., Wang, Q., Asmani, M., Li, Y., Liu, C., Li, C., Lippmann, J. M., Wu, Y., & Zhao, R. (2016) · Scientific Reports · doi:10.1038/srep31304 · Cited by 35
Self-citationBiomechanics in hemostasis and thrombosis
Weisel, J. W. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.03808.x · Cited by 23
Zhang, C., Kelkar, A., Nasirikenari, M., Lau, J. T. Y., Sveinsson, M., Sharma, U. C., Pokharel, S., & Neelamegham, S. (2017) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13927 · Cited by 17
Self-citationEffect of Hemodynamic Forces on Platelet Aggregation Geometry
Tolouei, E., Butler, C. J., Fouras, A., Ryan, K., Sheard, G. J., & Carberry, J. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0239-4 · Cited by 15
Dayananda, K. M., Gogia, S., & Neelamegham, S. (2010) · Analytical Biochemistry · doi:10.1016/j.ab.2010.12.005 · Cited by 13
Self-citation
Cited by
Blood clot contraction: Mechanisms, pathophysiology, and disease
Litvinov, R. I., & Weisel, J. W. (2023) · Research and Practice in Thrombosis and Haemostasis · doi:10.1016/j.rpth.2022.100023 · Cited by 123
Technology Advancements in Blood Coagulation Measurements for Point-of-Care Diagnostic Testing
Aria, M. M., Erten, A. C., & Yalçın, Ö. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00395 · Cited by 104
“Figure 2C shows the device which consists of a top microfluidic channel layer, a middle PDMS substrate with the micro-tissue array, and a bottom stretchable membrane (Chen et al., 2019).”
BackgroundXu, Y., Ying, L., Lang, J. K., Hinz, B., & Zhao, R. (2024) · Science Advances · doi:10.1126/sciadv.adj9559 · Cited by 67
Self-citationMontague, S. J., Lim, Y. J., Lee, W. M., & Gardiner, E. E. (2020) · Frontiers in Immunology · doi:10.3389/fimmu.2020.00078 · Cited by 57
Engineering Biomaterials and Approaches for Mechanical Stretching of Cells in Three Dimensions
Zhang, W., Huang, G., & Xu, F. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.589590 · Cited by 47
Metadata
- Authors
- Chen, Z., Lu, J., Zhang, C., Hsia, I., Yu, X., Marecki, L., Marecki, E., Asmani, M., Jain, S., Neelamegham, S., & Zhao, R.
- Affiliations
- University at Buffalo, State University of New York (US)
- Women & Children's Hospital of Buffalo (US)
- Corresponding author
- Neelamegham, Sriram
- Zhao, Ruogang
- ORCID
- Venue
- Nature Communications
- Published
- 2019-05-03
- Volume
- 10
- Issue
- 1
- Pages
- 2051-2051
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC6499828
- OpenAlex
- W2943462406
- Cited by
- 64
- References
- 52
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 8 · 2023: 10 · 2022: 9 · 2021: 10 · 2020: 13 · 2019: 2
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- U.S. Department of Health & Human Services | NIH | National Institute of Biomedical Imaging and Bioengineering (R01EB019411)
- Topics
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
- Health Sciences › Medicine › Hematology › Platelet Disorders and Treatments
- Keywords
- coagulation, thrombus formation, elastometry, microfluidics, platelet adhesion, antiplatelet therapy, bleeding disorders, procoagulants, antiplatelet agents, patient plasma
- MeSH terms
- Blood Coagulation, Blood Platelets, Female, Hemorrhage, Humans, Male, Platelet Aggregation Inhibitors, Stress, Mechanical, Thrombelastography, Microfluidics, Tissue Array Analysis, von Willebrand Disease, Type 2, Human Umbilical Vein Endothelial Cells, Healthy Volunteers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.