Ultrabright gap-enhanced Raman tags for high-speed bioimaging
Open accessThe DOI matches its Crossref record; 65 of the 67 references it cites were found in a registry or an index.
Abstract
Surface-enhanced Raman spectroscopy (SERS) is advantageous over fluorescence for bioimaging due to ultra-narrow linewidth of the fingerprint spectrum and weak photo-bleaching effect. However, the existing SERS imaging speed lags far behind practical needs, mainly limited by Raman signals of SERS nanoprobes. In this work, we report ultrabright gap-enhanced Raman tags (GERTs) with strong electromagnetic hot spots from interior sub-nanometer gaps and external petal-like shell structures, larger immobilization surface area, and Raman cross section of reporter molecules. These GERTs reach a Raman enhancement factor beyond 5 × 10 9 and a detection sensitivity down to a single-nanoparticle level. We use a 370 μW laser to realize high-resolution cell imaging within 6 s and high-contrast (a signal-to-background ratio of 80) wide-area (3.2 × 2.8 cm 2) sentinel lymph node imaging within 52 s. These nanoprobes offer a potential solution to overcome the current bottleneck in the field of SERS-based bioimaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“(1) large enhancement factor, detectable down to a single-NP level42,49, leading to the fastest (to the best of our knowledge) readout speed with a good signal-to-noise ratio;”
From Gap-enhanced Raman tags for physically unclonable anticounterfeiting labels (2020) · cites this paper as [42]
In the citing paper
“Gap-enhanced Raman tags (GERTs) with embedded Raman reporters show strong intensity enhancement and ultra-high photostability suitable for fast and repeated readout of PUF labels.”
From Gap-enhanced Raman tags for physically unclonable anticounterfeiting labels (2020) · cites this paper as [42]
In the citing paper
“a PUF label (100 × 100 μm2) fabricated using 4-NBT GERTs was mapped with a shortened exposure time of around 0.7 ms per pixel, which is by now the shortest acquisition time of commercial electron-multiplying charge-coupled device (EMCCD) as far as we know42.”
From Gap-enhanced Raman tags for physically unclonable anticounterfeiting labels (2020) · cites this paper as [42]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of the Noble Metals
Johnson, P. B., & Christy, R. W. (1972) · Physical Review B · doi:10.1103/physrevb.6.4370 · Cited by 20,094
Single Molecule Detection Using Surface-Enhanced Raman Scattering (SERS)
Kneipp, K., Wang, Y., Kneipp, H., Perelman, L. T., Itzkan, I., Dasari, R. R., & Feld, M. S. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.1667 · Cited by 6,816
Shell-isolated nanoparticle-enhanced Raman spectroscopy
Li, J. F., Huang, Y. F., Ding, Y., Yang, Z. L., Li, S. B., Zhou, X. S., Fan, F. R., Zhang, W., Zhou, Z. Y., Wu, D. Y., et al. (2010) · Nature · doi:10.1038/nature08907 · Cited by 3,559
Surface Enhanced Raman Scattering Enhancement Factors: A Comprehensive Study
Le Ru, E. C., Blackie, E., Meyer, M., & Etchegoin, P. G. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp0687908 · Cited by 2,853
Maeda, H. (2001) · Advances in Enzyme Regulation · doi:10.1016/s0065-2571(00)00013-3 · Cited by 2,495
In vivo tumor targeting and spectroscopic detection with surface-enhanced Raman nanoparticle tags
Qian, X., Peng, X.-H., Ansari, D. O., Yin-Goen, Q., Chen, G. Z., Shin, D. M., Yang, L., Young, A. N., Wang, M. D., & Nie, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1377 · Cited by 2,201
Electromagnetic theories of surface-enhanced Raman spectroscopy
Ding, S.-Y., You, E.-M., Tian, Z.-Q., & Moskovits, M. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00238f · Cited by 1,553
SERS Tags: Novel Optical Nanoprobes for Bioanalysis
Wang, Y., Yan, B., & Chen, L. (2013) · Chemical Reviews · doi:10.1021/cr300120g · Cited by 1,331
Lim, D.-K., Jeon, K.-S., Hwang, J.-H., Kim, H., Kwon, S., Suh, Y. D., & Nam, J.-M. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.79 · Cited by 1,142
Kircher, M. F., de la Zerda, A., Jokerst, J. V., Zavaleta, C. L., Kempen, P. J., Mittra, E., Pitter, K., Huang, R., Campos, C., Habte, F., et al. (2012) · Nature Medicine · doi:10.1038/nm.2721 · Cited by 1,064
Cited by
Surface-enhanced Raman spectroscopy
Han, X. X., Rodriguez, R. S., Haynes, C. L., Ozaki, Y., & Zhao, B. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00083-6 · Cited by 907
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 566
SERS Tags for Biomedical Detection and Bioimaging
Liu, H., Gao, X., Xu, C., & Liu, D. (2022) · Theranostics · doi:10.7150/thno.66859 · Cited by 301
Gap-enhanced Raman tags for physically unclonable anticounterfeiting labels
Gu, Y., He, C., Zhang, Y., Lin, L., Thackray, B. D., & Ye, J. (2020) · Nature Communications · doi:10.1038/s41467-019-14070-9 · Cited by 268
Self-citationLin, L. L., Alvarez-Puebla, R., Liz-Marzán, L. M., Trau, M., Wang, J., Fabris, L., Wang, X., Liu, G., Xu, S., Han, X. X., et al. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c17502 · Cited by 247
Self-citation
Metadata
- Authors
- Zhang, Y., Gu, Y., He, J., Thackray, B. D., & Ye, J.
- Venue
- Nature Communications
- Published
- 2019-08-29
- Volume
- 10
- Issue
- 1
- Pages
- 3905-3905
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2970591283
- Cited by
- 256
- References
- 67
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.