Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.

Single ion qubit with estimated coherence time exceeding one hour

Open access
Wang, Pengfei, Luan, Chun-Yang, Qiao, Mu, Um, Mark, Zhang, Junhua, Wang, Ye, Yuan, Xiao, Gu, Mile, Zhang, Jingning, Kim, Kihwan · 2021 · Nature Communications

Abstract

Realizing a long coherence time quantum memory is a major challenge of current quantum technology. Until now, the longest coherence-time of a single qubit was reported as 660 s in a single 171 Yb + ion-qubit through the technical developments of sympathetic cooling and dynamical decoupling pulses, which addressed heating-induced detection inefficiency and magnetic field fluctuations. However, it was not clear what prohibited further enhancement. Here, we identify and suppress the limiting factors, which are the remaining magnetic-field fluctuations, frequency instability and leakage of the microwave reference-oscillator. Then, we observe the coherence time of around 5500 s for the 171 Yb + ion-qubit, which is the time constant of the exponential decay fit from the measurements up to 960 s. We also systematically study the decoherence process of the quantum memory by using quantum process tomography and analyze the results by applying recently developed resource theories of quantum memory and coherence. Our experimental demonstration will accelerate practical applications of quantum memories for various quantum information processing, especially in the noisy-intermediate-scale quantum regime.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-020-20330-w

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Experimental setup. a Energy levels of 171Yb+ and 138Ba+ ion and cutaway view of the μ-metal shielding enclosing octagon chamber. The shielding has ten holes, where two holes for connection of the vacuum pump and helical resonator and the other eight holes with diameter from 20 to 40 mm for the access of laser beams, microwave, and imaging system. b The schematic diagram for the control of microwave and laser beams. We use a crystal oscillator (SIMAKE SMK3627OCHFM OCXO) to reference the microwave generator and Direct Digital Synthesize (DDS) through a 1 GHz signal generator. The microwave of 12.6 GHz is generated by mixing 200 MHz signal from DDS and 12.4 GHz from the microwave generator, which is amplified and applied to ions through a horn. All three microwave switches are used to reduce microwave leakage. For 369 nm laser beams, we use acousto-optic modulators (AOMs) to generate basic operating lasers. We use Electro-Optic pulse picker (EOPP), mechanical shutter and single-mode fiber to reduce laser leakage. The magnetic-field direction is in the radial direction. We detect the qubit state with a photomultiplier tube (PMT).
Fig. 1 Experimental setup. a Energy levels of 171Yb+ and 138Ba+ ion and cutaway view of the μ-metal shielding enclosing octagon chamber. The shielding has ten holes, where two holes for connection of the vacuum pump and helical resonator and the other eight holes with diameter from 20 to 40 mm for the access of laser beams, microwave, and imaging system. b The schematic diagram for the control of microwave and laser beams. We use a crystal oscillator (SIMAKE SMK3627OCHFM OCXO) to reference the microwave generator and Direct Digital Synthesize (DDS) through a 1 GHz signal generator. The microwave of 12.6 GHz is generated by mixing 200 MHz signal from DDS and 12.4 GHz from the microwave generator, which is amplified and applied to ions through a horn. All three microwave switches are used to reduce microwave leakage. For 369 nm laser beams, we use acousto-optic modulators (AOMs) to generate basic operating lasers. We use Electro-Optic pulse picker (EOPP), mechanical shutter and single-mode fiber to reduce laser leakage. The magnetic-field direction is in the radial direction. We detect the qubit state with a photomultiplier tube (PMT).CC BY · PubMed Central
Fig. 2 Experimental sequence. Cooling laser beams for the 138Ba+ ion are applied during the whole sequence. For 171Yb+ ion, we first initialize the qubit and then start to apply the microwave pulses. All the KDDxy(Knill dynamical decoupling) pulses are inserted between two π/2 pulses of Ramsey sequence. Blue and brown blocks represent Doppler cooling and optical pumping pulses for 171Yb+ ion. EOPP and shutter are closed after state initialization and opened before state readout, where the time delays between them are shown as Δt ≈ 10 ms, which is mainly caused by the limited speed of the mechanical shutter. Gray blocks represent KDDxyunits. T is the total measurement time, and τ is the interval of pulses. Each KDDxy unit has ten π pulses, where the first and the second five pulses represent σx- and σy-rotation, respectively. Therefore, the second five pulses have 90° phase shift from the first five. We choose the total number of KDDxyunits even to make sure all the KDDxy pulses are identity operation in the ideal case. In the end, we use a detection laser pulse to measure the qubit state.
Fig. 2 Experimental sequence. Cooling laser beams for the 138Ba+ ion are applied during the whole sequence. For 171Yb+ ion, we first initialize the qubit and then start to apply the microwave pulses. All the KDDxy(Knill dynamical decoupling) pulses are inserted between two π/2 pulses of Ramsey sequence. Blue and brown blocks represent Doppler cooling and optical pumping pulses for 171Yb+ ion. EOPP and shutter are closed after state initialization and opened before state readout, where the time delays between them are shown as Δt ≈ 10 ms, which is mainly caused by the limited speed of the mechanical shutter. Gray blocks represent KDDxyunits. T is the total measurement time, and τ is the interval of pulses. Each KDDxy unit has ten π pulses, where the first and the second five pulses represent σx- and σy-rotation, respectively. Therefore, the second five pulses have 90° phase shift from the first five. We choose the total number of KDDxyunits even to make sure all the KDDxy pulses are identity operation in the ideal case. In the end, we use a detection laser pulse to measure the qubit state.CC BY · PubMed Central
Fig. 3 Blue points are from the initial states of ∣0⟩ and ∣1⟩, and red points are from ∣0⟩+∣1⟩, ∣0⟩+i∣1⟩, ∣0⟩−∣1⟩, and ∣0⟩−i∣1⟩, where ϕ = 0, π/2, π, and 3π/2, respectively. Error bars are standard deviations. Each initial state at each data point repeats 30 to 100 times. The solid lines are the fitting results by the exponential decay function. Inset shows extrapolations of fits in a longer time range. The shadow indicates the enlarged area in the figure. The red-dashed line indicates the previous result of superposition states28. The black-dashed line indicates the 1/e threshold. The red and blue arrows indicate times when threshold are reached.
Fig. 3 Blue points are from the initial states of ∣0⟩ and ∣1⟩, and red points are from ∣0⟩+∣1⟩, ∣0⟩+i∣1⟩, ∣0⟩−∣1⟩, and ∣0⟩−i∣1⟩, where ϕ = 0, π/2, π, and 3π/2, respectively. Error bars are standard deviations. Each initial state at each data point repeats 30 to 100 times. The solid lines are the fitting results by the exponential decay function. Inset shows extrapolations of fits in a longer time range. The shadow indicates the enlarged area in the figure. The red-dashed line indicates the previous result of superposition states28. The black-dashed line indicates the 1/e threshold. The red and blue arrows indicate times when threshold are reached.CC BY · PubMed Central
Fig. 4 Results of quantum process tomography. a Red and blue points represent process and mean fidelities, respectively. Error bars are standard deviations. The red line is the fitting result of Eq. (1). The blue line is the fitting result of the exponential decay function. Inset shows extrapolations of fits in a longer time range. The shadow indicates the enlarged area in the figure. The red and blue dashed horizontal lines indicate the process fidelity and mean fidelity of the final state, where the system lost all the quantum information. The blue vertical line indicates the time point when mean fidelity decays to 1/e threshold. (b), The real part of the process matrix after a storage time of (i): 4 min, (ii): 8 min, and (iii): 16 min. The largest diagonal element of the process matrix is the identity operation part, χ11^exp, which is the process fidelity Fp. (c), State evolution represented in the Bloch sphere after a storage time of (i): 4 min, (ii): 8 min, and (iii): 16 min. Gray meshed spheres represent the initial pure states, which form the Bloch sphere. And blue spheres represent the output states after corresponding storage time, which are the same as the input state at T = 0 but shrink into the Bloch sphere later and transition to a dot in the center for T≫min(T1,T2). Given the input state, the corresponding output state is calculated by the process matrix χ^exp.
Fig. 4 Results of quantum process tomography. a Red and blue points represent process and mean fidelities, respectively. Error bars are standard deviations. The red line is the fitting result of Eq. (1). The blue line is the fitting result of the exponential decay function. Inset shows extrapolations of fits in a longer time range. The shadow indicates the enlarged area in the figure. The red and blue dashed horizontal lines indicate the process fidelity and mean fidelity of the final state, where the system lost all the quantum information. The blue vertical line indicates the time point when mean fidelity decays to 1/e threshold. (b), The real part of the process matrix after a storage time of (i): 4 min, (ii): 8 min, and (iii): 16 min. The largest diagonal element of the process matrix is the identity operation part, χ11^exp, which is the process fidelity Fp. (c), State evolution represented in the Bloch sphere after a storage time of (i): 4 min, (ii): 8 min, and (iii): 16 min. Gray meshed spheres represent the initial pure states, which form the Bloch sphere. And blue spheres represent the output states after corresponding storage time, which are the same as the input state at T = 0 but shrink into the Bloch sphere later and transition to a dot in the center for T≫min(T1,T2). Given the input state, the corresponding output state is calculated by the process matrix χ^exp.CC BY · PubMed Central
Fig. 5 Benchmark of quantum memory and coherence. Red and blue points are data of the robustness of quantum memory (RQM) and the mean ratio of the relative entropy of coherence (REC), respectively. Error bars are standard deviations. The red line is the theoretical result of the RQM calculated from the process matrix of Eq. (1) and the blue line is the exponential fitting result of the mean ratio of the REC. Inset shows extrapolations of fits in a longer time range. The shadow indicates the enlarged area in the figure. The blue vertical line indicates the time point when the mean REC ratio decays to 1/e.
Fig. 5 Benchmark of quantum memory and coherence. Red and blue points are data of the robustness of quantum memory (RQM) and the mean ratio of the relative entropy of coherence (REC), respectively. Error bars are standard deviations. The red line is the theoretical result of the RQM calculated from the process matrix of Eq. (1) and the blue line is the exponential fitting result of the mean ratio of the REC. Inset shows extrapolations of fits in a longer time range. The shadow indicates the enlarged area in the figure. The blue vertical line indicates the time point when the mean REC ratio decays to 1/e.CC BY · PubMed Central
Fig. 6 Expected limitations of coherence time. The left boundaries of different color-bars indicate expected limitations caused by corresponding decoherence sources as follows: (i) Phase noise of local oscillator; (ii) Magnetic-field fluctuation; (iii) Ion hopping; (iv) Scatting of 138Ba+ lasers; (v) Leakage of the microwave; (vi) Collision of background gas; (vii) Lifetime of hyperfine ground-state. Currently, the coherence time is mainly limited by the phase noise of the local oscillator and the ultimate coherence time limited by the lifetime of the hyperfine state is estimates as around 5 × 1011 s.
Fig. 6 Expected limitations of coherence time. The left boundaries of different color-bars indicate expected limitations caused by corresponding decoherence sources as follows: (i) Phase noise of local oscillator; (ii) Magnetic-field fluctuation; (iii) Ion hopping; (iv) Scatting of 138Ba+ lasers; (v) Leakage of the microwave; (vi) Collision of background gas; (vii) Lifetime of hyperfine ground-state. Currently, the coherence time is mainly limited by the phase noise of the local oscillator and the ultimate coherence time limited by the lifetime of the hyperfine state is estimates as around 5 × 1011 s.CC BY · PubMed Central
Fig. 7 Suppression of magnetic-field noise. To check the noise suppression of magnetic-field shielding, we use 31 CPMG (Carr, Purcell, Meiboom, and Gill) pulses to accumulate the AC magnetic-field noise28. The figure shows Ramsey contrast as a function of the inter-DD pulse spacing τ. Black and red points represent data without and with shielding and permanent magnet28, respectively. Before the improvement of magnetic field stability, there are two dips at τ = 3.3 ms and τ = 10 ms which correspond to 150 Hz and 50 Hz noise, respectably, which disappeared after the improvement. We further increase the CPMG pulses number to 190, and get fringe contrasts of 0.97 and 0.98 at τ = 10 ms and 3.3 ms, respectively. This indicates that the level of the noise at 50 Hz and 150 Hz are below 16 μG and 32 μG, respectively.
Fig. 7 Suppression of magnetic-field noise. To check the noise suppression of magnetic-field shielding, we use 31 CPMG (Carr, Purcell, Meiboom, and Gill) pulses to accumulate the AC magnetic-field noise28. The figure shows Ramsey contrast as a function of the inter-DD pulse spacing τ. Black and red points represent data without and with shielding and permanent magnet28, respectively. Before the improvement of magnetic field stability, there are two dips at τ = 3.3 ms and τ = 10 ms which correspond to 150 Hz and 50 Hz noise, respectably, which disappeared after the improvement. We further increase the CPMG pulses number to 190, and get fringe contrasts of 0.97 and 0.98 at τ = 10 ms and 3.3 ms, respectively. This indicates that the level of the noise at 50 Hz and 150 Hz are below 16 μG and 32 μG, respectively.CC BY · PubMed Central
Fig. 8 Fitting of process matrix elements evolution. Blue and black points are experimental results of χIZ and χXY, respectively. The solid lines are their fitting results.
Fig. 8 Fitting of process matrix elements evolution. Blue and black points are experimental results of χIZ and χXY, respectively. The solid lines are their fitting results.CC BY · PubMed Central
Fig. 9 Coherence time obtained from Ramsey measurements. a without dynamical decoupling pulses and (b) with one spin-echo pulse. Blue points are experimental results and each point repeats 100 times. The solid lines are their fitting by the Gaussian decay function. (a) A small detuning between microwave frequency and qubit energy splitting is used here to observe the oscillation signal rather than the fringe contrast signal to wipe out the frequency drift effect. The coherence time is 1.6 ± 0.22 s. b The red-dashed line indicates the 1/e threshold. The coherence time is 11.1 ± 0.38 s.
Fig. 9 Coherence time obtained from Ramsey measurements. a without dynamical decoupling pulses and (b) with one spin-echo pulse. Blue points are experimental results and each point repeats 100 times. The solid lines are their fitting by the Gaussian decay function. (a) A small detuning between microwave frequency and qubit energy splitting is used here to observe the oscillation signal rather than the fringe contrast signal to wipe out the frequency drift effect. The coherence time is 1.6 ± 0.22 s. b The red-dashed line indicates the 1/e threshold. The coherence time is 11.1 ± 0.38 s.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 57 references

Research works printed but not linked: 3

  1. Nielsen, M. A. & Chuang, I. L. Quantum Computation and Quantum Information (Cambridge University Press, 2010).
  2. Sarvepalli, P. K., Klappenecker, A. & Rotteler, M. Asymmetric quantum codes: constructions, bounds and performance. Proc. R. Soc. Lond., Ser. A 465, 1645–1672 (2009).
  3. May, V. & Kühn, O. Charge and Energy Transfer Dynamics in Molecular Systems (John Wiley and Sons, Ltd, 2007).

Cited by

See all 368

Metadata

Authors
Wang, P., Luan, C.-Y., Qiao, M., Um, M., Zhang, J., Wang, Y., Yuan, X., Gu, M., Zhang, J., & Kim, K.
Affiliations
  • Tsinghua University (CN)
  • Southern University of Science and Technology (CN)
  • Duke University (US)
  • Peking University (CN)
  • Centre for Quantum Technologies (SG)
Corresponding author
  • Wang, Pengfei
  • Kim, Kihwan
Venue
Nature Communications
Published
2021-01-11
Volume
12
Issue
1
Pages
233-233
ISSN
2041-1723 (ISSN-L)
OpenAlex
W3046827789
Cited by
321
References
57
Citations by year
2026: 45 · 2025: 81 · 2024: 58 · 2023: 62 · 2022: 47 · 2021: 27
FWCI
17.14
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • National University of Singapore (submittedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • DR-NTU (Nanyang Technological University) (submittedVersion)
Funders
National Natural Science Foundation of China (11504197)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum optics and atomic interactions
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Computing Algorithms and Architecture
Keywords
171Yb, coherence time, quantum memory, decoherence, magnetic fluctuations, frequency instability, quantum process tomography, coherence, noisy intermediate-scale quantum computing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Single ion qubit with estimated coherence time exceeding one hour. https://app.cochat.ai/papers/10.1038/s41467-020-20330-w
The paper
Wang, P., Luan, C.-Y., Qiao, M., Um, M., Zhang, J., Wang, Y., Yuan, X., Gu, M., Zhang, J., & Kim, K. (2021). Single ion qubit with estimated coherence time exceeding one hour. Nature Communications. https://doi.org/10.1038/s41467-020-20330-w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.