CoChat

Mechanically induced correlated errors on superconducting qubits with relaxation times exceeding 0.4 ms

Open access

The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.

Abstract

Superconducting qubits are among the most advanced candidates for achieving fault-tolerant quantum computing. Despite recent significant advancements in the qubit lifetimes, the origin of the loss mechanism for state-of-the-art qubits is still subject to investigation. Furthermore, the successful implementation of quantum error correction requires negligible correlated errors between qubits. Here, we realize long-lived superconducting transmon qubits that exhibit fluctuating lifetimes, averaging 0.2 ms and exceeding 0.4 ms – corresponding to quality factors above 5 million and 10 million, respectively. We then investigate their dominant error mechanism. By introducing novel time-resolved error measurements that are synchronized with the operation of the pulse tube cooler in a dilution refrigerator, we find that mechanical vibrations from the pulse tube induce nonequilibrium dynamics in highly coherent qubits, leading to their correlated bit-flip errors. Our findings not only deepen our understanding of the qubit error mechanisms but also provide valuable insights into potential error-mitigation strategies for achieving fault tolerance by decoupling superconducting qubits from their mechanical environments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-024-48230-3

Cites

76 of 76 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Long-lived superconducting transmon qubit device based on Nb capacitor electrodes. a False-colored optical micrograph of a superconducting device, consisting of four transmon qubits (yellow, Q0–Q3) with individual readout resonators (green) coupled to a shared Purcell filter (red). b False-colored scanning electron microscope images of an Al/AlOx/Al Josephson junction (blue) shunted by a Nb capacitor (yellow) on a silicon substrate (gray). c Equivalent circuit of the device. d Simplified cryogenic wiring. e, f Time traces of the excited-state probability of qubit Q0, showing the longest measured values of the relaxation time and the Ramsey and Hahn-echo dephasing times. g Long-term stability of the relaxation times of the four qubits. The middle panel shows the magnified plot for the gray region of the left panel, where the dots are the results obtained from the individual time traces, while the solid lines are their smoothed data with a 5 h time window. The right panel shows the height-wise normalized histograms.
Fig. 1 Long-lived superconducting transmon qubit device based on Nb capacitor electrodes. a False-colored optical micrograph of a superconducting device, consisting of four transmon qubits (yellow, Q0–Q3) with individual readout resonators (green) coupled to a shared Purcell filter (red). b False-colored scanning electron microscope images of an Al/AlOx/Al Josephson junction (blue) shunted by a Nb capacitor (yellow) on a silicon substrate (gray). c Equivalent circuit of the device. d Simplified cryogenic wiring. e, f Time traces of the excited-state probability of qubit Q0, showing the longest measured values of the relaxation time and the Ramsey and Hahn-echo dephasing times. g Long-term stability of the relaxation times of the four qubits. The middle panel shows the magnified plot for the gray region of the left panel, where the dots are the results obtained from the individual time traces, while the solid lines are their smoothed data with a 5 h time window. The right panel shows the height-wise normalized histograms.CC BY · PubMed Central
Fig. 2 Out of equilibrium dynamics of a transmon qubit, induced by mechanical vibrations from the pulse tube cooler. a Pulse scheme and simplified experimental setup for simultaneously recording both the vibrational noise generated by the pulse tube cooler (PT) and the single-shot qubit readout outcomes. b Time traces of the acceleration of the vibrational noise with the pulse tube cooler on (orange) and off (blue), and c the amplitude spectral densities (ASD) of their absolute values. The fundamental frequency of the harmonics is approximately 1.4 Hz. d Time traces of the readout quadrature amplitudes and e their ASDs. The black dashed lines show a threshold to distinguish between the G and E states and one between the E and F states, respectively. The quadrature amplitudes are normalized by the G-state quadrature standard deviation. The same normalization is carried out in every single-shot data in this work. f Histograms of the qubit readout quadrature amplitudes when the pulse tube cooler is on and off. The solid lines are the mixture of Gaussian distributions fitted to the histograms in order to obtain the occupation probabilities.
Fig. 2 Out of equilibrium dynamics of a transmon qubit, induced by mechanical vibrations from the pulse tube cooler. a Pulse scheme and simplified experimental setup for simultaneously recording both the vibrational noise generated by the pulse tube cooler (PT) and the single-shot qubit readout outcomes. b Time traces of the acceleration of the vibrational noise with the pulse tube cooler on (orange) and off (blue), and c the amplitude spectral densities (ASD) of their absolute values. The fundamental frequency of the harmonics is approximately 1.4 Hz. d Time traces of the readout quadrature amplitudes and e their ASDs. The black dashed lines show a threshold to distinguish between the G and E states and one between the E and F states, respectively. The quadrature amplitudes are normalized by the G-state quadrature standard deviation. The same normalization is carried out in every single-shot data in this work. f Histograms of the qubit readout quadrature amplitudes when the pulse tube cooler is on and off. The solid lines are the mixture of Gaussian distributions fitted to the histograms in order to obtain the occupation probabilities.CC BY · PubMed Central
Fig. 3 Mechanically induced correlated qubit excitations. a Height-wise normalized 2D histograms of the simultaneous readout quadrature outcomes for qubits Q0 and Q1 with the pulse tube cooler off and on, where the number of data points are approximately 3 × 105 and 107, respectively. b Time trace of the acceleration of a referential pulse tube vibrational noise within one period and c the result of its time-frequency analysis. There are two phases in one cycle of the pulse tube operation: helium gas flow in (red shaded) and out (blue shaded). d Time-resolved E- and F-state probabilities for Q0 and Q1, time-aligned to the referential vibrational noise. The dots and lines are the raw data with a 1 ms time resolution and their smoothed data with a 5 ms time window, respectively. e Mutual information as a function of time within the one vibrational period, obtained from the time-resolved simultaneous single-shot data for Q0 and Q1. The blue solid line is the time-resolved MI, while the orange dashed line is the non-time-resolved one. The confidence interval of one standard error is shown with the shaded region.
Fig. 3 Mechanically induced correlated qubit excitations. a Height-wise normalized 2D histograms of the simultaneous readout quadrature outcomes for qubits Q0 and Q1 with the pulse tube cooler off and on, where the number of data points are approximately 3 × 105 and 107, respectively. b Time trace of the acceleration of a referential pulse tube vibrational noise within one period and c the result of its time-frequency analysis. There are two phases in one cycle of the pulse tube operation: helium gas flow in (red shaded) and out (blue shaded). d Time-resolved E- and F-state probabilities for Q0 and Q1, time-aligned to the referential vibrational noise. The dots and lines are the raw data with a 1 ms time resolution and their smoothed data with a 5 ms time window, respectively. e Mutual information as a function of time within the one vibrational period, obtained from the time-resolved simultaneous single-shot data for Q0 and Q1. The blue solid line is the time-resolved MI, while the orange dashed line is the non-time-resolved one. The confidence interval of one standard error is shown with the shaded region.CC BY · PubMed Central
Fig. 4 Mechanically induced quantum jumps. a Pulse scheme for continuously monitoring the states of qubits Q0 and Q1, where multiplexed readout pulses are repeated successively, synchronized with the measurement of the vibrational noise from the pulse tube cooler. b An example of a time trace of the single-shot readout quadrature for Q0, showing several quantum jumps. The shaded blue, red, and green regions correspond to the dwell events in the G, E, and F states, respectively. The event time, centered at each dwell event, is shown with a vertical dashed line, while the dwell time is shown with a double-sided horizontal arrow. c–e 2D histograms of the event time and the dwell times in the G, E, and F states, respectively. The histograms are normalized by the height at the first dwell time bin for every event time. f, g Time-resolved dwell-time distributions for G, E, and F, and for different times specified with dashed lines in (h). The black lines are the fitting results. h Time-resolved total transition rates from the G, E, and F states to the other two (ΓG, ΓE, and ΓF), respectively, time-aligned to the referential periodic vibrational noise (orange). i Time-resolved individual transition rates among the G, E, and F states. The shaded regions in (h, i) depict the errors obtained from the fitting errors of the dwell-time distributions and the statistical errors of the conditional probabilities.
Fig. 4 Mechanically induced quantum jumps. a Pulse scheme for continuously monitoring the states of qubits Q0 and Q1, where multiplexed readout pulses are repeated successively, synchronized with the measurement of the vibrational noise from the pulse tube cooler. b An example of a time trace of the single-shot readout quadrature for Q0, showing several quantum jumps. The shaded blue, red, and green regions correspond to the dwell events in the G, E, and F states, respectively. The event time, centered at each dwell event, is shown with a vertical dashed line, while the dwell time is shown with a double-sided horizontal arrow. c–e 2D histograms of the event time and the dwell times in the G, E, and F states, respectively. The histograms are normalized by the height at the first dwell time bin for every event time. f, g Time-resolved dwell-time distributions for G, E, and F, and for different times specified with dashed lines in (h). The black lines are the fitting results. h Time-resolved total transition rates from the G, E, and F states to the other two (ΓG, ΓE, and ΓF), respectively, time-aligned to the referential periodic vibrational noise (orange). i Time-resolved individual transition rates among the G, E, and F states. The shaded regions in (h, i) depict the errors obtained from the fitting errors of the dwell-time distributions and the statistical errors of the conditional probabilities.CC BY · PubMed Central
Fig. 5 Correlation analysis on quantum jumps. a Table of the total 16 error probabilities of qubits Q0 and Q1, taken at the time interval which maximizes the MI, where the data is clipped to the minimum of 10−4. b Mutual information (MI) between the error probabilities of Q0 and Q1, as a function of the time interval. The dashed line marks the time interval showing the maximal MI.
Fig. 5 Correlation analysis on quantum jumps. a Table of the total 16 error probabilities of qubits Q0 and Q1, taken at the time interval which maximizes the MI, where the data is clipped to the minimum of 10−4. b Mutual information (MI) between the error probabilities of Q0 and Q1, as a function of the time interval. The dashed line marks the time interval showing the maximal MI.CC BY · PubMed Central
Fig. 6 Qubit excitations induced by a controlled pure mechanical shock. a Pulse scheme and simplified experimental setup for simultaneously recording the qubit single-shot readout outcomes and a vibrational noise generated by a controlled mechanical shock. In addition to the oscilloscope setup for the vibration measurement, an AWG sends a synchronized switching signal to trigger a current in an electromagnet, leading to a mechanical shock. b Multiple time traces of the acceleration signal generated by the controlled mechanical shock and c the result of time-frequency analysis of one of them. d Time-resolved E- and F-state probabilities for qubits Q0 and Q1, synchronized with the controlled mechanical shock while the pulse tube cooler is deactivated. The dots and lines are the raw data with a 10 ms time resolution and their smoothed data with a 50 ms time window, respectively.
Fig. 6 Qubit excitations induced by a controlled pure mechanical shock. a Pulse scheme and simplified experimental setup for simultaneously recording the qubit single-shot readout outcomes and a vibrational noise generated by a controlled mechanical shock. In addition to the oscilloscope setup for the vibration measurement, an AWG sends a synchronized switching signal to trigger a current in an electromagnet, leading to a mechanical shock. b Multiple time traces of the acceleration signal generated by the controlled mechanical shock and c the result of time-frequency analysis of one of them. d Time-resolved E- and F-state probabilities for qubits Q0 and Q1, synchronized with the controlled mechanical shock while the pulse tube cooler is deactivated. The dots and lines are the raw data with a 10 ms time resolution and their smoothed data with a 50 ms time window, respectively.CC BY · PubMed Central
Fig. 7 Time-resolved measurement of the microwave bath. a Pulse scheme for characterizing the qubit microwave bath, where 2.5 μs long coherent pulses are repeated with an interval of 1 ms, synchronized with the measurement of the vibrational noise from the pulse tube cooler. b Time trace of the acceleration of the pulse tube vibrational noise within one period. c, d Transmission coefficient and background photon noise of the microwave bath, measured in a time-resolved fashion and synchronized with the periodic vibrational noise. The transmission coefficient and background noise are normalized by the non-time-resolved values, respectively. Moreover, the background noise is re-scaled to the vacuum noise level (1/2), to be in the unit of quanta. The dots and lines are the raw data with a 1 ms time resolution and their smoothed data with a 5 ms time window, respectively.
Fig. 7 Time-resolved measurement of the microwave bath. a Pulse scheme for characterizing the qubit microwave bath, where 2.5 μs long coherent pulses are repeated with an interval of 1 ms, synchronized with the measurement of the vibrational noise from the pulse tube cooler. b Time trace of the acceleration of the pulse tube vibrational noise within one period. c, d Transmission coefficient and background photon noise of the microwave bath, measured in a time-resolved fashion and synchronized with the periodic vibrational noise. The transmission coefficient and background noise are normalized by the non-time-resolved values, respectively. Moreover, the background noise is re-scaled to the vacuum noise level (1/2), to be in the unit of quanta. The dots and lines are the raw data with a 1 ms time resolution and their smoothed data with a 5 ms time window, respectively.CC BY · PubMed Central
Fig. 8 Schematic of experimental setup. Cryogenic wiring and room temperature measurement setup.
Fig. 8 Schematic of experimental setup. Cryogenic wiring and room temperature measurement setup.CC BY · PubMed Central
Fig. 9 Sample holder and package, electric hammer, and accelerometer. a Two slots for sample holders. The DUT is mounted inside the multilayer shielding at the bottom slot. b Multi-qubit device wire-bonded to a PCB on a sample table. An Al lid is covered to suppress qubit radiation loss. c Electric hammer based on an electromagnet. An accelerometer is attached to the jig for the hammer.
Fig. 9 Sample holder and package, electric hammer, and accelerometer. a Two slots for sample holders. The DUT is mounted inside the multilayer shielding at the bottom slot. b Multi-qubit device wire-bonded to a PCB on a sample table. An Al lid is covered to suppress qubit radiation loss. c Electric hammer based on an electromagnet. An accelerometer is attached to the jig for the hammer.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 76 references

Cited by

See all 71

Metadata

Authors
Kono, S., Pan, J., Chegnizadeh, M., Wang, X., Youssefi, A., Scigliuzzo, M., & Kippenberg, T. J.
Affiliations
École Polytechnique Fédérale de Lausanne (CH)
Corresponding author
  • Kono, Shingo
  • Kippenberg, Tobias J.
Venue
Nature Communications
Published
2024-05-10
Volume
15
Issue
1
Pages
3950-3950
ISSN
2041-1723 (ISSN-L)
OpenAlex
W4396799032
Cited by
50
References
76
Citations by year
2026: 12 · 2025: 29 · 2024: 9
FWCI
7.38
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
Funders
  • National Science Foundation (51NF40-185902, 204927)
  • European Commission (101033361)
  • École Polytechnique Fédérale de Lausanne
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (51NF40, 185902, 204927)
  • Horizon 2020 Framework Programme (EU‐H2020, 835329)
  • National Center of Competence in Research Quantum Science and Technology (185902, 51NF40-185902)
  • H2020 European Research Council (835329)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Computing Algorithms and Architecture
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
Keywords
superconducting qubits, transmon qubits, correlated errors, bit-flip errors, qubit relaxation time, mechanical vibration, pulse tube refrigerator, dilution refrigerator, nonequilibrium dynamics, error mitigation, fault-tolerant quantum computing, quality factor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanically induced correlated errors on superconducting qubits with relaxation times exceeding 0.4 ms. https://app.cochat.ai/papers/10.1038/s41467-024-48230-3
The paper
Kono, S., Pan, J., Chegnizadeh, M., Wang, X., Youssefi, A., Scigliuzzo, M., & Kippenberg, T. J. (2024). Mechanically induced correlated errors on superconducting qubits with relaxation times exceeding 0.4 ms. Nature Communications. https://doi.org/10.1038/s41467-024-48230-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.