Prolonged energy harvesting for ingestible devices
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Ingestible electronics have revolutionized the standard of care for a variety of health conditions. Extending the capacity and safety of these devices, and reducing the costs of powering them, could enable broad deployment of prolonged-monitoring systems for patients. Although previous biocompatible power-harvesting systems for in vivo use have demonstrated short (minute-long) bursts of power from the stomach, little is known about the potential for powering electronics in the longer term and throughout the gastrointestinal tract. Here, we report the design and operation of an energy-harvesting galvanic cell for continuous in vivo temperature sensing and wireless communication. The device delivered an average power of 0.23 μW mm−2 of electrode area for an average of 6.1 days of temperature measurements in the gastrointestinal tract of pigs. This power-harvesting cell could provide power to the next generation of ingestible electronic devices for prolonged periods of time inside the gastrointestinal tract. A biocompatible, energy-harvesting electrochemical cell delivers power to a wireless sensor for an average of 6.1 days of temperature measurements in the gastrointestinal tract of pigs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
CRC Handbook of Chemistry and Physics
(2016) · CRC Press eBooks · doi:10.1201/9781315380476 · Cited by 13,921
Trumbo (2001) · doi:10.1016/s0002-8223(01)00078-5 · Cited by 4,852
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Nutrition Board. Panel on Micronutrients (2001) · Medical Entomology and Zoology · Cited by 1,675
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
A controlled-release microchip
Santini, J. T., Cima, M. J., & Langer, R. (1999) · Nature · doi:10.1038/16898 · Cited by 868
Self-citationElectrochemical corrosion of unalloyed copper in chloride media––a critical review
Kear, G., Barker, B. D., & Walsh, F. C. (2004) · Corrosion Science · doi:10.1016/s0010-938x(02)00257-3 · Cited by 805
A Battery-Less Thermoelectric Energy Harvesting Interface Circuit With 35 mV Startup Voltage
Ramadass, Y. K., & Chandrakasan, A. P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2074090 · Cited by 578
Self-citationWireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
Cited by
Ouyang, H., Liu, Z., Li, N., Shi, B., Zou, Y., Xie, F., Ma, Y., Li, Z., Li, H., Zheng, Q., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09851-1 · Cited by 647
Emerging Implantable Energy Harvesters and Self-Powered Implantable Medical Electronics
Jiang, D., Shi, B., Ouyang, H., Fan, Y., Wang, Z. L., & Li, Z. (2020) · ACS Nano · doi:10.1021/acsnano.9b08268 · Cited by 343
A human pilot trial of ingestible electronic capsules capable of sensing different gases in the gut
Kalantar-Zadeh, K., Berean, K. J., Ha, N., Chrimes, A. F., Xu, K., Grando, D., Ou, J. Z., Pillai, N., Campbell, J. L., Brkljača, R., et al. (2018) · Nature Electronics · doi:10.1038/s41928-017-0004-x · Cited by 342
Piezoelectric energy harvesters for biomedical applications
Ali, F., Raza, W., Li, X., Gul, H., & Kim, K.-H. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.01.012 · Cited by 300
Implantable Energy‐Harvesting Devices
Shi, B., Li, Z., & Fan, Y. (2018) · Advanced Materials · doi:10.1002/adma.201801511 · Cited by 290
Ingestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
Self-citationNanomaterial Patterning in 3D Printing
Elder, B., Neupane, R., Tokita, E., Ghosh, U., Hales, S., & Kong, Y. L. (2020) · Advanced Materials · doi:10.1002/adma.201907142 · Cited by 265
Self-citationRational design of silicon structures for optically controlled multiscale biointerfaces
Jiang, Y., Li, X., Liu, B., Yi, J., Fang, Y., Shi, F., Gao, X., Sudzilovsky, E., Parameswaran, R., Koehler, K., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0230-1 · Cited by 254
Wireless on-demand drug delivery
Mirvakili, S. M., & Langer, R. (2021) · Nature Electronics · doi:10.1038/s41928-021-00614-9 · Cited by 202
Self-citationA Fully Biodegradable Battery for Self‐Powered Transient Implants
Huang, X., Wang, D., Yuan, Z., Xie, W., Wu, Y., Li, R., Zhao, Y., Luo, D., Cen, L., Chen, B., et al. (2018) · Small · doi:10.1002/smll.201800994 · Cited by 199
Karan, S. K., Maiti, S., Lee, J. H., Mishra, Y. K., Khatua, B. B., & Kim, J. K. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202004446 · Cited by 195
A fully biodegradable and self-electrified device for neuroregenerative medicine
Wang, L., Lu, C., Yang, S., Sun, P., Wang, Y., Guan, Y., Liu, S., Cheng, D., Meng, H., Wang, Q., et al. (2020) · Science Advances · doi:10.1126/sciadv.abc6686 · Cited by 195
Flexible piezoelectric devices for gastrointestinal motility sensing
Dagdeviren, C., Javid, F., Joe, P., von Erlach, T., Bensel, T., Wei, Z., Saxton, S., Cleveland, C., Booth, L., McDonnell, S., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0140-7 · Cited by 194
Self-citationRecent progress on biodegradable materials and transient electronics
Li, R., Wang, L., Kong, D., & Yin, L. (2018) · Bioactive Materials · doi:10.1016/j.bioactmat.2017.12.001 · Cited by 193
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Self-citationCustom-Made Electrochemical Energy Storage Devices
Lv, Z., Li, W., Yang, L., Loh, X. J., & Chen, X. (2019) · ACS Energy Letters · doi:10.1021/acsenergylett.8b02408 · Cited by 176
Robotic wireless capsule endoscopy: recent advances and upcoming technologies
Cao, Q., Deng, R., Pan, Y., Liu, R., Chen, Y., Gong, G., Zou, J., Yang, H., & Han, D. (2024) · Nature Communications · doi:10.1038/s41467-024-49019-0 · Cited by 165
“A prospective solution could be a new form of self-powered battery that directly harnesses the digestive system ’ s energy, transforming gastric fl uid into a virtually unlimited electrolyte supply to extend battery life 14,15 .”
Edible Electronics: The Vision and the Challenge
Sharova, A. S., Melloni, F., Lanzani, G., Bettinger, C. J., & Caironi, M. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202000757 · Cited by 165
Lu, T., Ji, S., Jin, W., Yang, Q., Luo, Q., & Ren, T.-L. (2023) · Sensors · doi:10.3390/s23062991 · Cited by 159
Miniature battery-free bioelectronics
Nair, V., Dalrymple, A. N., Yu, Z., Balakrishnan, G., Bettinger, C. J., Weber, D. J., Yang, K., & Robinson, J. T. (2023) · Science · doi:10.1126/science.abn4732 · Cited by 128
“Using magnesium or zinc anodes and copper cathodes, gastro-intestinal batteries produced average power densities of 0.23 m W/mm 2 and were able to power ingestible central temperature sensors with wireless data transmission capabilities ( 35 ).”
BackgroundInfluentialSensing gastrointestinal motility
Haghiashtiani, G., & McAlpine, M. C. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0146-1 · Cited by 4
Metadata
- Authors
- Nadeau, P., El-Damak, D., Glettig, D., Kong, Y. L., Mo, S., Cleveland, C., Booth, L., Roxhed, N., Langer, R., Chandrakasan, A. P., & Traverso, G.
- Venue
- Nature Biomedical Engineering
- Published
- 2017-02-06
- Volume
- 1
- Issue
- 3
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W2587707451
- Cited by
- 219
- References
- 40
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.