Prolonged energy harvesting for ingestible devices
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Ingestible electronics have revolutionized the standard of care for a variety of health conditions. Extending the capacity and safety of these devices, and reducing the costs of powering them, could enable broad deployment of prolonged-monitoring systems for patients. Although previous biocompatible power-harvesting systems for in vivo use have demonstrated short (minute-long) bursts of power from the stomach, little is known about the potential for powering electronics in the longer term and throughout the gastrointestinal tract. Here, we report the design and operation of an energy-harvesting galvanic cell for continuous in vivo temperature sensing and wireless communication. The device delivered an average power of 0.23 μW mm−2 of electrode area for an average of 6.1 days of temperature measurements in the gastrointestinal tract of pigs. This power-harvesting cell could provide power to the next generation of ingestible electronic devices for prolonged periods of time inside the gastrointestinal tract. A biocompatible, energy-harvesting electrochemical cell delivers power to a wireless sensor for an average of 6.1 days of temperature measurements in the gastrointestinal tract of pigs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
CRC Handbook of Chemistry and Physics
(2016) · CRC Press eBooks · doi:10.1201/9781315380476 · Cited by 13,921
Trumbo (2001) · doi:10.1016/s0002-8223(01)00078-5 · Cited by 4,852
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Nutrition Board. Panel on Micronutrients (2001) · Medical Entomology and Zoology · Cited by 1,675
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
A controlled-release microchip
Santini, J. T., Cima, M. J., & Langer, R. (1999) · Nature · doi:10.1038/16898 · Cited by 868
Self-citationElectrochemical corrosion of unalloyed copper in chloride media––a critical review
Kear, G., Barker, B. D., & Walsh, F. C. (2004) · Corrosion Science · doi:10.1016/s0010-938x(02)00257-3 · Cited by 805
A Battery-Less Thermoelectric Energy Harvesting Interface Circuit With 35 mV Startup Voltage
Ramadass, Y. K., & Chandrakasan, A. P. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2074090 · Cited by 578
Self-citationWireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
Materials, Designs, and Operational Characteristics for Fully Biodegradable Primary Batteries
Yin, L., Huang, X., Xu, H., Zhang, Y., Lam, J., Cheng, J., & Rogers, J. A. (2014) · Advanced Materials · doi:10.1002/adma.201306304 · Cited by 336
A pH-responsive supramolecular polymer gel as an enteric elastomer for use in gastric devices
Zhang, S., Bellinger, A. M., Glettig, D. L., Barman, R., Lee, Y.-A. L., Zhu, J., Cleveland, C., Montgomery, V. A., Gu, L., Nash, L. D., et al. (2015) · Nature Materials · doi:10.1038/nmat4355 · Cited by 326
Self-citationMicrochips as Controlled Drug-Delivery Devices
Santini, Jr., Richards, A. C., Scheidt, R., Cima, M. J., & Langer, R. (2000) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20000717)39:14<2396::aid-anie2396>3.0.co;2-u · Cited by 271
Self-citationA Glucose Fuel Cell for Implantable Brain–Machine Interfaces
Rapoport, B. I., Kedzierski, J. T., & Sarpeshkar, R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038436 · Cited by 242
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Maqbool, S., Parkman, H. P., & Friedenberg, F. K. (2009) · Digestive Diseases and Sciences · doi:10.1007/s10620-009-0899-9 · Cited by 235
An Ingestible Sensor for Measuring Medication Adherence
Hafezi, H., Robertson, T. L., Moon, G. D., Au-Yeung, K.-Y., Zdeblick, M. J., & Savage, G. M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2341272 · Cited by 226
Energy extraction from the biologic battery in the inner ear
Mercier, P. P., Lysaght, A. C., Bandyopadhyay, S., Chandrakasan, A. P., & Stankovic, K. M. (2012) · Nature Biotechnology · doi:10.1038/nbt.2394 · Cited by 217
Self-citationMicroneedles for Drug Delivery via the Gastrointestinal Tract
Traverso, G., Schoellhammer, C. M., Schroeder, A., Maa, R., Lauwers, G. Y., Polat, B. E., Anderson, D. G., Blankschtein, D., & Langer, R. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24182 · Cited by 202
Self-citationWaters, B. H., Sample, A. P., Bonde, P., & Smith, J. R. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165309 · Cited by 169
Ultrasound-mediated gastrointestinal drug delivery
Schoellhammer, C. M., Schroeder, A., Maa, R., Lauwers, G. Y., Swiston, A. J., Zervas, M. J., Barman, R. A., DiCiccio, A. M., Brugge, W. R., Anderson, D. G., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa5937 · Cited by 143
Self-citationAccuracy of Peripheral Thermometers for Estimating Temperature
Niven, D. J., Laupland, K. B., & Stelfox, H. T. (2016) · Annals of Internal Medicine · doi:10.7326/l16-0069 · Cited by 135
A 0.20 $\text {mm}^2$ 3 nW Signal Acquisition IC for Miniature Sensor Nodes in 65 nm CMOS
Harpe, P., Gao, H., Dommele, R. V., Cantatore, E., & van Roermund, A. H. M. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2487270 · Cited by 124
Self-deployable current sources fabricated from edible materials
Kim, Y. J., Chun, S.-E., Whitacre, J., & Bettinger, C. J. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb20183j · Cited by 124
A novel ingestible electronic drug delivery and monitoring device
Schaar, P. J. V. D., Dijksman, J., Gast, H. S. B.-D., Shimizu, J., van Lelyveld, N., Zou, H., Iordanov, V. P., Wanke, C., & Siersema, P. D. (2013) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2013.03.170 · Cited by 122
Maio, S. D., & Carrier, R. L. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.11.034 · Cited by 110
Pakalapati, L. V. V. (2003) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 99
A 10 bit SAR ADC With Data-Dependent Energy Reduction Using LSB-First Successive Approximation
Yaul, F. M., & Chandrakasan, A. P. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2352304 · Cited by 98
Self-citationElectroceuticals spark interest
Reardon, S. (2014) · Nature · doi:10.1038/511018a · Cited by 91
Capsule endoscopy: The road ahead
Sîngeap, A.-M., Stanciu, C., & Trifan, A. (2015) · World Journal of Gastroenterology · doi:10.3748/wjg.v22.i1.369 · Cited by 86
Perspective: Special delivery for the gut
Traverso, G., & Langer, R. (2015) · Nature · doi:10.1038/519s19a · Cited by 80
Self-citationGastrointestinal Transit of Nondisintegrating, Nonerodible Oral Dosage Forms in Pigs
Hossain, M. S., Abramowitz, W., Watrous, B. J., Szpunar, G. J., & Ayres, J. W. (1990) · Pharmaceutical Research · doi:10.1023/a:1015936426906 · Cited by 65
Snoeck, V., Huyghebaert, N., Cox, E., Vermeire, A., Saunders, J. H., Remon, J. P., Verschooten, F., & Goddeeris, B. M. (2003) · Journal of Controlled Release · doi:10.1016/j.jconrel.2003.09.015 · Cited by 62
Mostafalu, P., & Sonkusale, S. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.040 · Cited by 60
Gastric-fluid-utilizing micro battery for micro medical devices
Jimbo, H., & Miki, N. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.04.049 · Cited by 49
Endoluminal bariatric techniques
Kethu, S. R., Banerjee, S., Barth, B. A., Desilets, D. J., Kaul, V., Pedrosa, M. C., Pfau, P. R., Pleskow, D. K., Tokar, J. L., Wang, A., et al. (2012) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2012.02.020 · Cited by 47
Physiologic Status Monitoring via the Gastrointestinal Tract
Traverso, G., Ciccarelli, G. A., Schwartz, S. J., Hughes, T., Boettcher, T., Barman, R. A., Langer, R., & Swiston, A. J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0141666 · Cited by 41 · cited 2×
“2a–c) and consisted of an 8 bit digitally controlled potentiometer27 to set the load resistance of the cell, and a microcontroller system on a chip28 and its associated peripherals, which contained (1) a 10 bit analogue-to-digital converter (ADC) that measured the electrode voltage, (2) a temperature sensor, (3) a wir…”
BackgroundMethodSelf-citationBiofluid Activated Microbattery for Disposable Microsystems
Garay, E. F., & Bashirullah, R. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2317177 · Cited by 17
A +10dBm 2.4GHz Transmitter with sub-400pW Leakage and 43.7% System Efficiency
Paidimarri, A., Ickes, N., & Chandrakasan, A. P. (2015) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 17
Self-citationImprovements in biogalvanic energy sources
Roy, O. Z., & Wehnert, R. W. (1974) · Medical & Biological Engineering & Computing · doi:10.1007/bf02629834 · Cited by 6
Cited by
Ouyang, H., Liu, Z., Li, N., Shi, B., Zou, Y., Xie, F., Ma, Y., Li, Z., Li, H., Zheng, Q., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09851-1 · Cited by 647
Emerging Implantable Energy Harvesters and Self-Powered Implantable Medical Electronics
Jiang, D., Shi, B., Ouyang, H., Fan, Y., Wang, Z. L., & Li, Z. (2020) · ACS Nano · doi:10.1021/acsnano.9b08268 · Cited by 343
A human pilot trial of ingestible electronic capsules capable of sensing different gases in the gut
Kalantar-Zadeh, K., Berean, K. J., Ha, N., Chrimes, A. F., Xu, K., Grando, D., Ou, J. Z., Pillai, N., Campbell, J. L., Brkljača, R., et al. (2018) · Nature Electronics · doi:10.1038/s41928-017-0004-x · Cited by 342
Piezoelectric energy harvesters for biomedical applications
Ali, F., Raza, W., Li, X., Gul, H., & Kim, K.-H. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.01.012 · Cited by 300
Implantable Energy‐Harvesting Devices
Shi, B., Li, Z., & Fan, Y. (2018) · Advanced Materials · doi:10.1002/adma.201801511 · Cited by 290
Metadata
- Authors
- Nadeau, P., El-Damak, D., Glettig, D., Kong, Y. L., Mo, S., Cleveland, C., Booth, L., Roxhed, N., Langer, R., Chandrakasan, A. P., & Traverso, G.
- Venue
- Nature Biomedical Engineering
- Published
- 2017-02-06
- Volume
- 1
- Issue
- 3
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W2587707451
- Cited by
- 219
- References
- 40
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.