Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 254

The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.

Rational design of silicon structures for optically controlled multiscale biointerfaces

Open access
Jiang, Yuanwen, Li, Xiaojian, Liu, Bing, Yi, Jaeseok, Fang, Yin, Shi, Fengyuan, Gao, Xiang, Sudzilovsky, Edward, Parameswaran, Ramya, Koehler, Kelliann, Nair, Vishnu, Yue, Jiping, Guo, KuangHua, Fang, Yin, Tsai, Hsiu-Ming, Freyermuth, George, Wong, Raymond C. S., Kao, Chien-Min, Chen, Chin-Tu, Nicholls, Alan W., Wu, Xiaoyang, Shepherd, Gordon M. G., Tian, Bozhi·2018·Nature Biomedical Engineering

Abstract

Silicon-based materials have been widely used in biological applications. However, remotely controlled and interconnect-free silicon configurations have been rarely explored, because of limited fundamental understanding of the complex physicochemical processes that occur at interfaces between silicon and biological materials. Here, we describe rational design principles, guided by biology, for establishing intracellular, intercellular and extracellular silicon-based interfaces, where the silicon and the biological targets have matched properties. We focused on light-induced processes at these interfaces, and developed a set of matrices to quantify and differentiate the capacitive, Faradaic and thermal outputs from about 30 different silicon materials in saline. We show that these interfaces are useful for the light-controlled non-genetic modulation of intracellular calcium dynamics, of cytoskeletal structures and transport, of cellular excitability, of neurotransmitter release from brain slices and of brain activity in vivo. Intracellular, intercellular and extracellular silicon interfaces enable light-controlled non-genetic modulation of intracellular calcium dynamics, of cellular excitability, of neurotransmitter release from brain slices, and of brain activity in vivo.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41551-018-0230-1

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 57 references

Cited by

See all 254

Metadata

Authors
Jiang, Y., Li, X., Liu, B., Yi, J., Fang, Y., Shi, F., Gao, X., Sudzilovsky, E., Parameswaran, R., Koehler, K., Nair, V., Yue, J., Guo, K., Fang, Y., Tsai, H.-M., Freyermuth, G., Wong, R. C. S., Kao, C.-M., Chen, C.-T., Nicholls, A. W., Wu, X., Shepherd, G. M. G., & Tian, B.
Venue
Nature Biomedical Engineering
Published
2018-04-30
Volume
2
Issue
7
Pages
508-521
ISSN
2157-846X (ISSN-L)
OpenAlex
W2799538659
Cited by
254
References
57
FWCI
10.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rational design of silicon structures for optically controlled multiscale biointerfaces. https://app.cochat.ai/papers/10.1038/s41551-018-0230-1
The paper
Jiang, Y., Li, X., Liu, B., Yi, J., Fang, Y., Shi, F., Gao, X., Sudzilovsky, E., Parameswaran, R., Koehler, K., Nair, V., Yue, J., Guo, K., Fang, Y., Tsai, H.-M., Freyermuth, G., Wong, R. C. S., Kao, C.-M., Chen, C.-T., . . . Tian, B. (2018). Rational design of silicon structures for optically controlled multiscale biointerfaces. Nature Biomedical Engineering. https://doi.org/10.1038/s41551-018-0230-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.